NDNicholas Devenish

Nicholas Devenish

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicholas Devenish has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Drop-on-fixed-target reaction initiation approach for serial and time-resolved crystallography

    by Jos J. A. G. Kamps, Philip Hinchliffe, Johan Glerup, Emily I. Freeman, Pauline A. Lang, Catherine L. Tooke, Michael Beer, Laura Parkinson, Do-Heon Gu, Sehan Park, et al.

    We describe the design and implementation of a drop-on-fixed-target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume aqueous droplets (∼40–90 pl; ∼40–55 µm diameter sphere), containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals previously loaded into the trapezoidal wells of an etched crystalline silicon fixed-target chip containing 25 600 wells in a high-density, square grid with 125 µm centre-to-centre well spacing. These features demand exquisite accuracy and thereby constrain motion controls to enable robust time-resolved crystallographic studies. The system was tested with three enzyme systems, comprising lysozyme and two β-lactamases, CTX-M-15 and AmpC EC . Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free-electron laser facilities was evaluated. This drop-on-fixed-target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.


  • Open Access

    Report of high data rate macromolecular crystallography (HDRMX) meeting, 23 July 2025

    by Christine Beavers, Herbert J. Bernstein, Aaron S. Brewster, Max Burian, Nicholas Devenish, Jiaxin Dawn Duan, Daniel Eriksson, Diego Gämperle, Yang Ha, David R. Hall, et al.

    This paper is a report of the High Data Rate Macromolecular Crystallography workshop held on 23 July 2025 as part of the 2025 meeting of the American Crystallographic Association in Lombard, IL, USA, 18–23 July 2025. This report summarizes the discussions, questions, action items, and recommendations that arose from the meeting and includes links to the presentations. The sessions were moderated by Aaron S. Brewster and Graeme Winter. There was particularly lively discussion about the possible need for lossy compression as data rates increase, as multimodal experiments become more popular and as research budgets are squeezed.

  • Open Access

    Generation and modulation of catalytically relevant states of a dye-decolourizing peroxidase using time-resolved serial femtosecond crystallography with drop-on-chip mixing and X-ray-driven reduction

    by Marina Lučić, Johan Glerup, Pierre Aller, Danny Axford, Nicholas Devenish, Jaehyun Park, Anastasiia Shilova, Arturo Landeros de la Isla, Richard W. Strange, Tiankun Zhou, et al.

    Metalloenzymes containing a heme cofactor catalyse a wide range of oxidative reactions critical to life. Understanding the structure and electronic states of the heme across the catalytic cycle is essential in understanding the oxidative chemistry performed on the substrate. This work demonstrates in crystallo manipulation of the heme-iron oxidation state in a B-type dye-decolourizing peroxidase from Streptomyces lividans (DtpB) using multiple, complementary, serial crystallography approaches. Fixed-target drop-on-chip serial femtosecond crystallography (SFX) together with dose-resolved serial synchrotron crystallography (SSX) allowed DtpB to be driven between multiple iron oxidation states. Drop-on-chip addition of hydrogen peroxide with fixed-target SFX is used to generate a ferryl [Fe(IV)=O] species, while the X-ray-driven approach modulates the iron oxidation state, with an apparent two-electron reduction leading to a return to a ferric state. The formation and dose response of the Fe(IV)—O state is highly variable between the chemically identical heme groups of the DtpB hexamer, highlighting the importance of understanding the effect of the crystalline lattice on observed changes in time- and dose-resolved crystallography.

  • Open Access

    Experience with the Jungfrau-1M detector at Diamond Light Source

    by John Matheson, Danny Axford, Anna Bergamaschi, Maria Carulla, Nicholas Devenish, Noemi Frisina, Viktoria Hinger, Vadym Kedych, Christopher Lane, Aldo Mozzanica, et al.

    A Jungfrau-1M detector has undergone testing at Diamond Light Source. The Jungfrau series of detectors from PSI use integration and adaptive gain, to offer very high frame rate and dynamic range, suitable for high-flux and time-resolved measurements. They are becoming more widely used, to take advantage of increasing light source brightness. We report on our experiences in testing the performance of a Jungfrau-1M without illumination, with a laboratory X-ray tube and on a microfocus beamline. The Jungfrau-1M was found to be able to resolve single photons in the laboratory and on the beamline. It was confirmed that range switching from high to intermediate gain is associated with a discontinuity in the detector response. Two methods of dark frame subtraction were compared for their effect on minimizing this discontinuity. The Jungfrau-1M was found to be very effective for recording macromolecular crystallography diffraction patterns, with no apparent detriment from the discontinuity. The Diamond machine will be upgraded in 2028–9 and will operate at significantly higher flux than at present, necessitating increased use of integrating detectors, such as Jungfrau, in the future.

  • Open Access

    Time-resolved ligand dynamics revealed in a β-lactamase using room-temperature serial crystallography

    by Philip Hinchliffe, Catherine L Tooke, Michael Beer, Pierre Aller, Jos Jag Kamps, Laura Parkinson, Tiankun Zhou, Nicholas Devenish, Do-Heon Gu, Anastasya Shilova, et al.

    β-Lactamases catalyze β-lactam antibiotic hydrolysis and are important contributors to bacterial antimicrobial resistance; β-lactamase inhibitors are widely used to overcome β-lactamase-mediated antibiotic resistance. Nucleophilic serine β-lactamases (SBLs) react with their substrates and clinically available inhibitors via a covalent reaction to give complexes which can undergo further reaction. Using room temperature drop on fixed target serial crystallography, where ligands are rapidly mixed with microcrystals, and classical single-crystal crystallography at cryogenic temperatures, we investigate the reversible covalent reaction of the SBL CTX-M-15 with the diazobicyclooctane inhibitor avibactam. We observe avibactam covalently reacted (ring-opened) with the nucleophilic Ser70, at timepoints from 80 ms to minutes (room temperature) and hours (100 K). These crystallographic data reveal time-dependent movement of the avibactam carbamoyl complex, from 1.3 s onwards, that has implications for the 5-exo-trig recyclization mechanism that determines inhibitor reformation. Combined with molecular dynamics simulations and quantum mechanics calculations at the density functional theory level, the results show that in the first seconds of the reaction the avibactam N-sulfate nitrogen is poorly positioned for recyclization. This subsequently equilibrates after 10 s to a stable endpoint that is in a conformation potentially primed to initiate recyclization through attack of the N-sulfate nitrogen on the carbamoyl carbon. These results further demonstrate the capacity of room-temperature serial crystallography to capture time-resolved changes in ligand conformation at an enzyme active site, complementing discrete classical cryo-crystallography. These data inform on ligand dynamics and the stereoelectronics of diazobicyclooctane inhibition, aiding drug discovery efforts to develop inhibitors of nucleophilic enzymes.

  • Open Access

    Drop on fixed target reaction initiation approach for serial and time resolved crystallography

    by Jos J. A. G. Kamps, Philip Hinchliffe, Johan Glerup, Emily I. Freeman, Pauline A. Lang, Catherine L Tooke, Michael Beer, Laura Parkinson, Do-Heon Gu, Sehan Park, et al.

    We describe the design and implementation of a drop on fixed target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume (40 - 90 pL) aqueous droplets, containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals immobilised on a solid support. The system was tested with various enzyme systems, including lysozyme and two beta-lactamases, CTX-M-15 and AmpC. Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free electron laser facilities was evaluated. This drop on fixed target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.

  • Open Access

    Droplet on Demand Tape Drive and XES Prototypes for Time-Resolved Serial Crystallography at VMXi, Diamond Light Source

    by Pierre Aller, Juan Sanchez-Weatherby, Abbey Telfer, Robert Bosman, Nicholas Devenish, Philip Hinchliffe, Sam Horrell, Jophy Ip, Richard Littlewood, Andrew Male, et al.

    Time resolved X-ray crystallography is experiencing a resurgence, in part, because of serial methods that readily allow scientists to create stop-motion movies of macromolecular function of photoactivation, enzyme catalysed reactions, and ligand-induced conformational changes triggering further downstream signalling events. While some reactions can be initiated with light, either naturally or using photocaged compounds, a more generally applicable approach is to mix microcrystals with reagents at varying time points prior to exposure to the X-ray beam. A powerful approach has been to combine droplet on demand ‘tape drive’ sample delivery with X-ray emission spectroscopy (XES) that correlates atomic structure with electronic states of metal ions within the sample. To our knowledge, such a combined methodology has not been deployed previously at a synchrotron beamline and has been restricted to XFELs. Here we describe prototype experiments along the development pathway to a combined droplet on demand diffraction and XES system at the microfocus beamline VMXi at Diamond Light Source. We demonstrate the collection of a high-quality serial diffraction data set from microcrystals within hundreds of picolitre-volume droplets deposited on a moving tape. In separate experiments at VMXi, we collected XES data from microcrystals of a copper enzyme delivered using a high viscosity extruder. Together, these results demonstrate the feasibility of combined droplet on demand serial crystallography and XES experiments using a third-generation synchrotron beamline; project work currently underway at Diamond Light Source. Synopsis: We describe proof of concept experiments towards correlated serial crystallography (SSX) and X-ray emission spectroscopy (XES) from microcrystals at a microfocus synchrotron beamline. A droplet on demand tape drive system delivers microcrystals to the beam within well-separated, hundreds of picolitre-volume droplets while XES allows validation of redox states of metals within protein crystals.