PSPredrag M. Stojiljković

Predrag M. Stojiljković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Predrag M. Stojiljković has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Milan Mitkovic

    Niš University Clinical Centre, Academician Prof. Dr. Milorad Mitković Clinic for Orthopaedics and Traumatology, Niš, Serbia + University of Niš, Faculty of Medicine, Niš, Serbia

    2 shared publications
  • Sasa Milenkovic

    Niš University Clinical Centre, Academician Prof. Dr. Milorad Mitković Clinic for Orthopaedics and Traumatology, Niš, Serbia + University of Niš, Faculty of Medicine, Niš, Serbia

    2 shared publications
  • Asen V. Veličkov

    Universitätsklinik für Orthopädie und Traumatologie, Nis, Serbien

    1 shared publication
  • Miloš A. Nagorni

    University Clinical Center Niš, Academician Prof. Dr. Milorad Mitković, Clinic for Orthopedics and Traumatology, Niš, Serbia

    1 shared publication
  • Mladen J. Stojanović

    University Clinical Center of Niš, Academician Prof. Dr. Milorad Mitković Clinic for Orthopaedics and Traumatology, Niš, Serbia

    1 shared publication
  • Nikola J. Kostić

    University Clinical Center Niš, Academician Prof. Dr. Milorad Mitković, Clinic for Orthopedics and Traumatology, Niš, Serbia

    1 shared publication

Latest Publications

  • Open Access

    Influence of femoral shaft fracture extension into subtrochanteric or supracondylar region on operation and fluoroscopy time in dynamic extramedullary fixation

    by Milan M. Mitković, Saša S. Milenković, Predrag M. Stojiljković, Mladen J. Stojanović, Nikola J. Kostić, Miloš A. Nagorni

    Introduction/Objective. Although femoral shaft fractures are mostly treated by intramedullary fixation today, certain situations indicate extramedullary fixation for these fractures. The aim of this study was to evaluate the influence of femoral shaft fracture extension into the subtrochanteric or supracondylar region on operation time and intraoperative fluoroscopy time while performing dynamic extramedullary fixation. Method. A total of 90 cases of femoral shaft fractures treated using Selfdynamizable Internal Fixator (SIF) were analyzed. Patients were divided into three groups according to the applied implant type: femoral shaft fractures with proximal extension (SIF-troch), femoral shaft fractures without proximal or distal extension (SIF-shaft), and femoral shaft fractures with distal extension (SIF-cond). Results. The shortest mean operation time was observed in the SIF-shaft group, while the longest was recorded in fractures extending into the supracondylar region (SIF-cond group). The shortest average fluoroscopy time occurred in the SIF-shaft group, while the longest in the group with the fracture extension into the subtrochanteric region (SIF-troch group). Operation time was mainly influenced by the technique of lag screws and locking screws insertion and by the fracture reduction maintenance in the subtrochanteric and supracondylar regions. Conclusion. Extension of femoral shaft fractures into the subtrochanteric or supracondylar region is associated with increased operation and fluoroscopy times. SIF allows for dynamic extramedullary fixation, but also provides a relatively simple and fast performing surgical technique for femoral shaft fractures fixation, especially when the fracture does not extend beyond the shaft area.


  • Die Rolle der Kapsel-Ligamentotaxis und der minimalen perkutanen Osteosynthese mit starrer und dynamischer einseitiger externer Fixierung bei der intraartikulären Pilonfraktur

    by Predrag Stojiljkovic, Sasa Milenkovic, Asen Velickov, Milan Mitkovic

    Zusammenfassung Frakturen des Pilon der Tibia sind schwere Verletzungen, die mit einer mehr oder weniger ausgedehnten Zertrümmerung der Gelenkfläche und Weichteilverletzung einhergehen können. Weichteilverletzungen bei bereits bestehenden Hautschäden können die Behandlungsmethode zusätzlich erschweren. In solchen Fällen kann als alternative Behandlungsstrategie die Methode der einseitigen oder zirkulären externen Fixierung eingesetzt werden. Die minimale perkutane Osteosynthese mit (fraktur-)überspannender starrer und dynamischer einseitiger externer Fixation als einstufige Methode wurde zur Behandlung von intraartikulären Pilonfrakturen eingesetzt. Wir berichten über den Fall eines Patienten mit intraartikulärer Pilonfraktur bei chronisch venöser Insuffizienz und venösem Ulkus. Der Unfallmechanismus war ein Sturz aus 2,5 m Höhe. Notfallmäßig wurde mithilfe der Kapsel-Ligamentotaxis eine Reposition durchgeführt und mittels perkutanem überspannendem unilateralem Fixateur externe fixiert. Der Patient wurde postoperativ ohne Belastung des verletzten Beins mobilisiert. Die anfänglich starre externe Fixation wurde 8 Wochen postoperativ dynamisiert, nach 4,5 Monaten der Fixateur und 7 Monaten der Kirschner-Draht und die Schrauben entfernt. Das funktionelle Endergebnis ein Jahr nach der Verletzung war gut; die Beweglichkeit im oberen Sprunggelenk war schmerzfrei und nur endgradig eingeschränkt. Eine Schwellneigung trat nach längerer Gehstrecke auf.