Julius Viol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Julius Viol has a total of 246 co-authors. Here are the top co-authors by number of shared publications:
- Aditi Pradeep
SLAC National Laboratory 2575 Sand Hill Road Menlo Park 94025 CA USA
5 shared publications - David Sadek
University of Florida
5 shared publications - Emanuele Michielin
Institute for Astroparticle Physics (IAP)
5 shared publications - K. T. Kennard
Northwestern University
5 shared publications - Matthew James Wilson
University of British Columbia
5 shared publications - Noah Kurinsky
SLAC National Accelerator Laboratory
5 shared publications
Latest Publications
- Open Access
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector
We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV / c 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses > 1.2 eV / c 2 probed via absorption processes.
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Open AccessSearch for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector
We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV / c 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses > 1.2 eV / c 2 probed via absorption processes.
- Open Access
Performance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity
We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 612 meV $\pm$ 4 meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.81 eV $\pm$ 0.03 eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also place upper bounds on the nominal phonon collection efficiency of 45\%, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation.Open AccessPerformance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity
We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 612 meV $\pm$ 4 meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.81 eV $\pm$ 0.03 eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also place upper bounds on the nominal phonon collection efficiency of 45\%, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation. - 21 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (9)
Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps
- 21 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (9)
Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps