Ellie C. Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ellie C. Chen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jacob T. Robinson
Rice University
2 shared publications - Wei Wang
Department of Electrical and Computer Engineering, Rice University, Houston, TX, USA
2 shared publications - Abdelmotagaly Elgalad
Texas Heart Institute, Houston, TX, USA
1 shared publication Allison Post
Texas Heart Institute, Houston, TX, USA
1 shared publication- Angel Moctezuma-Ramirez
Center for Preclinical Surgical & Interventional Research, Section of Transplantation, Texas Heart Institute, Houston, TX 77030, USA
1 shared publication Drew Bernard
Texas Heart Institute, Houston, TX, USA
1 shared publication
Latest Publications
- Open Access
- 13 May 2026
- Published by Springer Nature in Communications Engineering
- Vol. 5 (1)
Robust magnetoelectric backscatter communication system for bioelectronic implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- 13 May 2026
- Published by Springer Nature in Communications Engineering
- Vol. 5 (1)
Open AccessRobust magnetoelectric backscatter communication system for bioelectronic implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- Open Access
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 1151-1165
Dual-Resonance Magnetoelectric Power and Data Links for Miniaturized Wireless Bio-Implants
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 1151-1165
Open AccessDual-Resonance Magnetoelectric Power and Data Links for Miniaturized Wireless Bio-Implants