Ayşe Demir Canbulut
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ayşe Demir Canbulut has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Emre Tokar
Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
2 shared publications - Merve Çakırbay Tanış
Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
2 shared publications - Bersu Bedirhandede
Department of Prosthodontics Faculty of Dentistry Gazi University Ankara Turkey
1 shared publication - Kürşat Eser
Department of Prosthodontics, Faculty of Dentistry, Aksaray University, Aksaray 68100, Turkey
1 shared publication - Nihal Tokar
N-Dent Oral and Dental Health Center, Ankara 06130, Türkiye
1 shared publication - Serdar Polat
Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
1 shared publication
Latest Publications
- Open Access
- 19 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 1001
The Effect of Sintering Protocols and Resin Cement Shades on the Optical Properties of Monolithic Zirconia Restorations
This study investigates the influence of different sintering protocols and resin cement shades on the optical properties of monolithic zirconia restorations. Zirconia, widely used in dentistry for its superior mechanical strength and esthetic potential, demonstrates phase transformations influenced by stabilizing oxides and processing conditions. While increasing yttria content enhances translucency, it compromises mechanical durability. Factors such as sintering temperature, grain size, porosity, and cement selection further affect translucency parameter, contrast ratio, and opalescence. In this research, 36 zirconia samples were divided into three groups according to sintering procedure performed; conventional, fast, and super-fast sintering. Each was tested with two shades of dual-cure resin cement (yellow and transparent). Optical parameters including translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) were measured using a spectrophotometer under controlled conditions. Statistically significant differences in OP values between the conventional sintering protocol and both the rapid and super-fast sintering protocols were found. A statistically significant difference was observed in OP values between the yellow and transparent cement groups. Neither the main effects of the sintering protocol nor the cement type were statistically significant on TP and CR values. However, a statistically significant interaction effect between the sintering protocol and cement type was observed for CR values. The findings highlight that both processing parameters and cement selection interaction play crucial roles in optimizing the TP and CR values of zirconia restorations, enabling improved esthetic outcomes in clinical practice.
- 19 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 1001
Open AccessThe Effect of Sintering Protocols and Resin Cement Shades on the Optical Properties of Monolithic Zirconia Restorations
This study investigates the influence of different sintering protocols and resin cement shades on the optical properties of monolithic zirconia restorations. Zirconia, widely used in dentistry for its superior mechanical strength and esthetic potential, demonstrates phase transformations influenced by stabilizing oxides and processing conditions. While increasing yttria content enhances translucency, it compromises mechanical durability. Factors such as sintering temperature, grain size, porosity, and cement selection further affect translucency parameter, contrast ratio, and opalescence. In this research, 36 zirconia samples were divided into three groups according to sintering procedure performed; conventional, fast, and super-fast sintering. Each was tested with two shades of dual-cure resin cement (yellow and transparent). Optical parameters including translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) were measured using a spectrophotometer under controlled conditions. Statistically significant differences in OP values between the conventional sintering protocol and both the rapid and super-fast sintering protocols were found. A statistically significant difference was observed in OP values between the yellow and transparent cement groups. Neither the main effects of the sintering protocol nor the cement type were statistically significant on TP and CR values. However, a statistically significant interaction effect between the sintering protocol and cement type was observed for CR values. The findings highlight that both processing parameters and cement selection interaction play crucial roles in optimizing the TP and CR values of zirconia restorations, enabling improved esthetic outcomes in clinical practice.
- Open Access
Trueness of Complete-Arch Implant Scans: Influence of Scanning Technique, Intraoral Scanner, and Implant Position (Part I: Linear and Angular Deviations)
Background and Objectives: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. Materials and Methods: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner–scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey’s HSD test was used to determine statistical differences. Significance was set at p < 0.05. Results: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (p < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. Conclusions: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1–3, 1–4, and 2–4.
Open AccessTrueness of Complete-Arch Implant Scans: Influence of Scanning Technique, Intraoral Scanner, and Implant Position (Part I: Linear and Angular Deviations)
Background and Objectives: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. Materials and Methods: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner–scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey’s HSD test was used to determine statistical differences. Significance was set at p < 0.05. Results: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (p < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. Conclusions: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1–3, 1–4, and 2–4.