Fan Yang
Fan Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Bolin Qiu
School of Petroleum Engineering, Southwest Petroleum University, Chengdu, 610500, China
1 shared publication- Changjun Li
Petroleum Engineering School, Southwest Petroleum University, Chengdu, China
1 shared publication Jiaming Sui
1 shared publication- Jian Le
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
1 shared publication - Jie He
College of Civil Engineering, Key Laboratory of Geotechnical and Underground Engineering, Department of Geotechnical Engineering, Tongji University, No. 1239 Siping Road, Shanghai 200092, China
1 shared publication - Jiuqing Ban
Research Institute of Natural Gas Technology, PetroChina Southwest Oil and Gas Field Company, Chengdu 610213, China
1 shared publication
Latest Publications
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 43, 611-618
Multi-objective Collaborative Optimization Control Method of Composite Function Grid Connected Inverters Considering Variable Weight Hybrid Decision Evaluation
Multi-functional grid connected inverter (MFGCI) has the ability to solve various power quality problems in the distribution network while fulfilling the power tracking task simultaneously, but this ability is often limited by its compensation capacity that can be used for power quality management. Based on the control structure of MFGCI, this paper provides the current compensation order and grid connection tracking current order without PLL. A multi-objective collaborative optimization method based on variable weight hybrid decision evaluation is proposed to better adapt to the fluctuations in power quality indicators caused by uncertainty in new energy and nonlinear load integration. A multi-objective function is constructed to achieve the best power quality compensation effect and the minimum required compensation capacity, an optimization algorithm based on the multi-objective artificial hummingbird algorithm (MOAHA) update mechanism is employed to solve the optimal capacity allocation coefficient for compensating various power quality problems. The correctness and effectiveness of the proposed method are verified through simulations in various scenarios.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 43, 611-618
Multi-objective Collaborative Optimization Control Method of Composite Function Grid Connected Inverters Considering Variable Weight Hybrid Decision Evaluation
Multi-functional grid connected inverter (MFGCI) has the ability to solve various power quality problems in the distribution network while fulfilling the power tracking task simultaneously, but this ability is often limited by its compensation capacity that can be used for power quality management. Based on the control structure of MFGCI, this paper provides the current compensation order and grid connection tracking current order without PLL. A multi-objective collaborative optimization method based on variable weight hybrid decision evaluation is proposed to better adapt to the fluctuations in power quality indicators caused by uncertainty in new energy and nonlinear load integration. A multi-objective function is constructed to achieve the best power quality compensation effect and the minimum required compensation capacity, an optimization algorithm based on the multi-objective artificial hummingbird algorithm (MOAHA) update mechanism is employed to solve the optimal capacity allocation coefficient for compensating various power quality problems. The correctness and effectiveness of the proposed method are verified through simulations in various scenarios.
- 13 November 2022
- Published by Elsevier in Journal of Petroleum Science and Engineering
- Vol. 220, 111241
Modeling transient cavitating flow in large drop crude oil pipelines
- 13 November 2022
- Published by Elsevier in Journal of Petroleum Science and Engineering
- Vol. 220, 111241
Modeling transient cavitating flow in large drop crude oil pipelines
- 11 October 2022
- Published by Taylor & Francis
- p. 198-203
Excavation deformation monitoring and numerical simulation analysis of a working well foundation pit at a metro station
Based on the deep foundation pit engineering of a subway station working well in Jinan, this paper uses the finite element software MIDAS GTS/NX to simulate the various construction stages of the deep foundation pit excavation. Through the analysis of field monitoring data, it is concluded that with the increase of foundation pit excavation depth, the horizontal displacement of the underground diaphragm wall and the surrounding surface settlement displacement are increasing. The maximum horizontal displacement of a deep layer is 12.8 mm during cushion construction; the surface subsidence displacement reaches the maximum at the edge distance of about 4 m away from the foundation pit. The simulation results are compared with the actual monitoring data, and the deformation law is basically consistent with the field monitoring. This paper discusses the influence of diaphragm wall thickness on foundation pit deformation: when the wall thickness is less than 1.0 m, the deformation of the diaphragm wall changes greatly, which has a great influence on the safety of the foundation pit.
- 11 October 2022
- Published by Taylor & Francis
- p. 198-203
Excavation deformation monitoring and numerical simulation analysis of a working well foundation pit at a metro station
Based on the deep foundation pit engineering of a subway station working well in Jinan, this paper uses the finite element software MIDAS GTS/NX to simulate the various construction stages of the deep foundation pit excavation. Through the analysis of field monitoring data, it is concluded that with the increase of foundation pit excavation depth, the horizontal displacement of the underground diaphragm wall and the surrounding surface settlement displacement are increasing. The maximum horizontal displacement of a deep layer is 12.8 mm during cushion construction; the surface subsidence displacement reaches the maximum at the edge distance of about 4 m away from the foundation pit. The simulation results are compared with the actual monitoring data, and the deformation law is basically consistent with the field monitoring. This paper discusses the influence of diaphragm wall thickness on foundation pit deformation: when the wall thickness is less than 1.0 m, the deformation of the diaphragm wall changes greatly, which has a great influence on the safety of the foundation pit.