AFAkira Furukawa

Akira Furukawa

*This is an algorithmically generated author record based on publicly available information.

Akira Furukawa has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Personal identification based on the radiographic images of the inverted findings of maxillary third molar and supernumerary mesiodens

    by Hirofumi Tsutsumi, Hikaru Izawa, Akira Furukawa, Toshinobu Komuro

    We report the identification of two unidentified bodies based on the high similarities in abnormal tooth eruption direction. The first case was an extremely rare case of identification by the dental finding of the inverted impacted maxillary third molar. The other was a relatively rare case of identification by the dental finding of the inverted impacted maxillary supernumerary mesiodens. For the two unidentified bodies in one case, it was easy to confirm their identities because the frequency of simultaneous appearance of inverted additional tooth or inverted supernumerary tooth in both was extremely low.

  • Cine-MR Image Segmentation for Assessment of Small Bowel Motility Function Using 3D U-Net

    by Kazuki Otsuki, Yutaro Iwamoto, Yen-Wei Chen, Akira Furukawa, Shuzo Kanasaki


  • Automated assessment of small bowel motility function based on three-dimensional zero-mean normalized cross correlation

    by Ayako Taniguchi, Akira Furukawa, Shuzo Kanasaki, Tomoko Tateyama, Yen-Wei Chen

    In this paper, we propose an automated method for assessment of small bowel contraction movement based on a three-dimensional zero-mean normalized cross correlation method (3D-ZNCC) with cine-MRI. The correlation value between frames is proportional to area change of the small bowel and the temporal area change can be used as a measure of the small bowel contraction movement. In the conventional two-dimensional zero-mean normalized correlation (2D-ZNCC) method, only frame A and frame B are used for calculation of correlation between frame A and frame B. Since a complex shape change of the intestine is irregular, it was difficult to detect contraction movement. In order to solve this problem, we propose to use 3D ZNCC, in which sequence frames are used for correlation calculations instead of single frame. Since not only spatial changes, but also temporal changes are included, we can detect the contraction movement correctly. Experimental results show that our method is better than conventional method.


  • Open Access

    Computer-Aided Diagnosis and Quantification of Cirrhotic Livers Based on Morphological Analysis and Machine Learning

    by Yen-Wei Chen, Jie Luo, Chunhua Dong, Xianhua Han, Tomoko Tateyama, Akira Furukawa, Shuzo Kanasaki

    It is widely known that morphological changes of the liver and the spleen occur during the clinical course of chronic liver diseases. In this paper, we proposed a morphological analysis method based on statistical shape models (SSMs) of the liver and spleen for computer-aided diagnosis and quantification of the chronic liver. We constructed not only the liver SSM but also the spleen SSM and a joint SSM of the liver and the spleen for a morphologic analysis of the cirrhotic liver in CT images. The effective modes are selected based on both its accumulation contribution rate and its correlation with doctor’s opinions (stage labels). We then learn a mapping function between the selected mode and the stage of chronic liver. The mapping function was used for diagnosis and staging of chronic liver diseases.


  • Open Access

    MR imaging of the normal appendix and acute appendicitis

    by Norihisa Nitta, Masashi Takahashi, Akira Furukawa, Kiyoshi Murata, Masayuki Mori, Masanobu Fukushima

    Purpose: To describe the MR appearance of the normal appendix and the MR imaging characteristics of acute appendicitis with correlation to pathological severity.Materials and Methods: A total of 20 volunteers participated in this study to demonstrate normal appendices by MR imaging. A total of 37 consecutive patients with clinically diagnosed acute appendicitis were also scanned. T1‐weighted (T1WI) spin‐echo images, T2‐weighted (T2WI) fast spin‐echo, and fat‐suppressed spectral presaturation inversion recovery T2‐weighted (T2SPIR) fast spin‐echo images were obtained. The MR criteria for considering acute appendicitis were as follows: 1) thickening of the appendiceal wall with high intensity on T2WI or T2SPIR; 2) dilated lumen filled with high intensity material on T2WI or T2SPIR; and 3) increased intensity of periappendiceal tissue on T2WI or T2SPIR.Results: The visibility of a normal appendix on MR imaging was 90% (18/20). It appeared as a cord‐like structure of medium intensity without fluid collection in the lumen. A total of 30 cases with clinically diagnosed acute appendicitis had positive MR findings and all except one were pathologically proven. The one had cecal diverticulitis. These cases demonstrated filled lumen, with a hypointense wall on T1WI and slightly hyperintense on T2WI or T2SPIR. MR findings correlated well with pathological severity, especially a thicker wall, periappendiceal high intensity, and ascites were useful for suspecting severe appendicitis.Conclusion: Correct diagnosis of acute appendicitis was obtained with MRI, and correlated well with its pathological severity. MRI is a powerful alternative for diagnosing acute appendicitis especially for the patients in whom the radiation is major concern. J. Magn. Reson. Imaging 2005;21:156–165.