YDY Deng

Y Deng

*This is an algorithmically generated author record based on publicly available information.

Y Deng has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • SU-E-T-283: Dose Perturbations Near Heterogeneity Junctions for Modulated-Scanning Protons

    by Y Deng, Y Li, Y Sheng, F Zhao, Z Huang, L Sun, J Zhao, M Moyers, W Hsi, K Shahnazi

  • MO‐F‐CAMPUS‐T‐04: Utilization of Optical Dosimeter for Modulated Spot‐Scanning Particle Beam

    by W Hsi, Y Li, Z Huang, Y Sheng, Y Deng, J Zhao, F Zhao, L Sun, M Moyers

    Purpose: To present the utilization of an optical dosimeter for modulated spot‐scanning carbon‐ion and proton beams during the acceptance test of Siemens IONTRIS system.Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated‐scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in‐diameter fields of 424.89 MeV/u (E290) carbon‐ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distances (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin‐thicknesses of chest‐board pattern and placing the scintillation plate at near to the distal edge, range variations at different off‐axis‐distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate.Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms.Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off‐axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot‐scanning particle system.

  • WE‐EF‐303‐11: Activity Distributions of Positron‐Emitting‐Isotopes Activated by Modulated Spot‐Scanning Particle Beams

    by W Hsi, Y Deng, L Sun, Y Li, Z Huang, Y Sheng, J Zhao, F Zhao

    Purpose: To present the characteristics of positron‐emitting‐isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot‐scanning carbon‐ions and protons in Siemens IONTRIS system.Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon‐ions and protons of 10cm uniform square field with single‐energy‐layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological‐equivalent doses of carbon‐ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions.Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon‐ions than by protons. For depths near at Bragg‐peak, penetration‐depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile‐fragments by carbon‐ions and target‐fragments by protons, respectively. For depths proximal to Bragg‐peak, target‐fragments for both carbon‐ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak‐like distributions were still observed for carbon‐ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts.Conclusions: Peak‐like PEI distributions by carbon‐ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in‐vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in‐vivo dose verification of target.