Hakan Aksoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hakan Aksoy has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Sercan Okutucu
Department of Cardiology, Memorial Ankara Hospital, Ankara, Turkey
5 shared publications Lale Tokgozoglu
Hacettepe University Faculty of Medicine, Department of Cardiology, Ankara, Turkey
4 shared publicationsAli Oto
Memorial Ankara Hospital, Department of Cardiology, Ankara, Turkey
3 shared publications- Kudret Aytemir
Department of Cardiology, Faculty of Medicine, Hacettepe University, Ankara, Turkey
3 shared publications - Ali Akdoğan
Department of Anesthesiology and Critical Care, Faculty of Medicine, Karadeniz Technical University, Trabzon, Türkiye
2 shared publications - Cengiz Sabanoglu
Department of Cardiology, Kirikkale Yuksek Ihtisas Hospital, Kirikkale, Turkey
2 shared publications
Latest Publications
- Open Access
- 30 June 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (3) , 242-249
Prolonged Tp-e interval and Tp-e/QT correlates well with modified Rodnan skin severity score in patients with systemic sclerosis
Background: Ventricular arrhythmias can be seen in systemic sclerosis (SSc) patients and are thought to be a result of fibrosis or ischemia of the ventricular myocardium. Tp-e interval and Tp-e/QT ratio are electrocardiographic (ECG) indices to predict ventricular tachyarrhythmia and cardiovascular mortality. We aimed to evaluate Tp-e interval and Tp-e/QT ratio in patients with SSc. Methods: A total of 107 patients with SSc (mean age, 48.6 ± 14.0 years; 96 females) and 100 healthy controls (mean age, 49.4 ± 8.6 years; 90 females) were enrolled. The standard 12-lead ECG was recorded; QTc, Tp-e interval and Tp-e/QT ratio were measured. Modified Rodnan skin severity score (MR-SSS) calculated for all SSc patients. Results: Tp-e interval (90.7 ± 23.8 ms vs. 84.0 ± 20.6 ms, p = 0.032) and Tp-e/QT ratio (0.20 ± 0.05 vs. 0.18 ± 0.04, p = 0.007, respectively) were significantly prolonged in SSc patients than in the control group. Pearson’s correlation analyses revealed positive correlations of MR-SSS with QTc (r = 0.427, p = 0.001), Tp-e interval (r = 0.620, p = 0.001) and Tp-e/ /QT ratio (r = 0.615, p = 0.001). MR-SSS (b = 2.108, p = 0.001) and CRP (b = 2.273, p = 0.027) were found to be significant independent predictors of Tp-e interval. Similarly, MR-SSS (b = 0.004, p = 0.001) was only a significant independent predictor of Tp-e/QT ratio among patients with SSc. Conclusions: The patients with SSc had a prolonged Tp-e interval and Tp-e/QT ratio compared with normal subjects. Furthermore, this prolongation was well correlated with clinical severity score among patients with SSc. Ventricular repolarization dispersion as a predictor of ventricular arrhythmias was found to be diminished in patients with SSc. Patients with SSc, particularly with higher MR-SSS, should be followed closely for adverse cardiovascular outcomes. Background: Ventricular arrhythmias can be seen in systemic sclerosis (SSc) patients and are thought to be a result of fibrosis or ischemia of the ventricular myocardium. Tp-e interval and Tp-e/QT ratio are electrocardiographic (ECG) indices to predict ventricular tachyarrhythmia and cardiovascular mortality. We aimed to evaluate Tp-e interval and Tp-e/QT ratio in patients with SSc. Methods: A total of 107 patients with SSc (mean age, 48.6 ± 14.0 years; 96 females) and 100 healthy controls (mean age, 49.4 ± 8.6 years; 90 females) were enrolled. The standard 12-lead ECG was recorded; QTc, Tp-e interval and Tp-e/QT ratio were measured. Modified Rodnan skin severity score (MR-SSS) calculated for all SSc patients. Results: Tp-e interval (90.7 ± 23.8 ms vs. 84.0 ± 20.6 ms, p = 0.032) and Tp-e/QT ratio (0.20 ± 0.05 vs. 0.18 ± 0.04, p = 0.007, respectively) were significantly prolonged in SSc patients than in the control group. Pearson’s correlation analyses revealed positive correlations of MR-SSS with QTc (r = 0.427, p = 0.001), Tp-e interval (r = 0.620, p = 0.001) and Tp-e/ /QT ratio (r = 0.615, p = 0.001). MR-SSS (b = 2.108, p = 0.001) and CRP (b = 2.273, p = 0.027) were found to be significant independent predictors of Tp-e interval. Similarly, MR-SSS (b = 0.004, p = 0.001) was only a significant independent predictor of Tp-e/QT ratio among patients with SSc. Conclusions: The patients with SSc had a prolonged Tp-e interval and Tp-e/QT ratio compared with normal subjects. Furthermore, this prolongation was well correlated with clinical severity score among patients with SSc. Ventricular repolarization dispersion as a predictor of ventricular arrhythmias was found to be diminished in patients with SSc. Patients with SSc, particularly with higher MR-SSS, should be followed closely for adverse cardiovascular outcomes.
- 30 June 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (3) , 242-249
Open AccessProlonged Tp-e interval and Tp-e/QT correlates well with modified Rodnan skin severity score in patients with systemic sclerosis
Background: Ventricular arrhythmias can be seen in systemic sclerosis (SSc) patients and are thought to be a result of fibrosis or ischemia of the ventricular myocardium. Tp-e interval and Tp-e/QT ratio are electrocardiographic (ECG) indices to predict ventricular tachyarrhythmia and cardiovascular mortality. We aimed to evaluate Tp-e interval and Tp-e/QT ratio in patients with SSc. Methods: A total of 107 patients with SSc (mean age, 48.6 ± 14.0 years; 96 females) and 100 healthy controls (mean age, 49.4 ± 8.6 years; 90 females) were enrolled. The standard 12-lead ECG was recorded; QTc, Tp-e interval and Tp-e/QT ratio were measured. Modified Rodnan skin severity score (MR-SSS) calculated for all SSc patients. Results: Tp-e interval (90.7 ± 23.8 ms vs. 84.0 ± 20.6 ms, p = 0.032) and Tp-e/QT ratio (0.20 ± 0.05 vs. 0.18 ± 0.04, p = 0.007, respectively) were significantly prolonged in SSc patients than in the control group. Pearson’s correlation analyses revealed positive correlations of MR-SSS with QTc (r = 0.427, p = 0.001), Tp-e interval (r = 0.620, p = 0.001) and Tp-e/ /QT ratio (r = 0.615, p = 0.001). MR-SSS (b = 2.108, p = 0.001) and CRP (b = 2.273, p = 0.027) were found to be significant independent predictors of Tp-e interval. Similarly, MR-SSS (b = 0.004, p = 0.001) was only a significant independent predictor of Tp-e/QT ratio among patients with SSc. Conclusions: The patients with SSc had a prolonged Tp-e interval and Tp-e/QT ratio compared with normal subjects. Furthermore, this prolongation was well correlated with clinical severity score among patients with SSc. Ventricular repolarization dispersion as a predictor of ventricular arrhythmias was found to be diminished in patients with SSc. Patients with SSc, particularly with higher MR-SSS, should be followed closely for adverse cardiovascular outcomes. Background: Ventricular arrhythmias can be seen in systemic sclerosis (SSc) patients and are thought to be a result of fibrosis or ischemia of the ventricular myocardium. Tp-e interval and Tp-e/QT ratio are electrocardiographic (ECG) indices to predict ventricular tachyarrhythmia and cardiovascular mortality. We aimed to evaluate Tp-e interval and Tp-e/QT ratio in patients with SSc. Methods: A total of 107 patients with SSc (mean age, 48.6 ± 14.0 years; 96 females) and 100 healthy controls (mean age, 49.4 ± 8.6 years; 90 females) were enrolled. The standard 12-lead ECG was recorded; QTc, Tp-e interval and Tp-e/QT ratio were measured. Modified Rodnan skin severity score (MR-SSS) calculated for all SSc patients. Results: Tp-e interval (90.7 ± 23.8 ms vs. 84.0 ± 20.6 ms, p = 0.032) and Tp-e/QT ratio (0.20 ± 0.05 vs. 0.18 ± 0.04, p = 0.007, respectively) were significantly prolonged in SSc patients than in the control group. Pearson’s correlation analyses revealed positive correlations of MR-SSS with QTc (r = 0.427, p = 0.001), Tp-e interval (r = 0.620, p = 0.001) and Tp-e/ /QT ratio (r = 0.615, p = 0.001). MR-SSS (b = 2.108, p = 0.001) and CRP (b = 2.273, p = 0.027) were found to be significant independent predictors of Tp-e interval. Similarly, MR-SSS (b = 0.004, p = 0.001) was only a significant independent predictor of Tp-e/QT ratio among patients with SSc. Conclusions: The patients with SSc had a prolonged Tp-e interval and Tp-e/QT ratio compared with normal subjects. Furthermore, this prolongation was well correlated with clinical severity score among patients with SSc. Ventricular repolarization dispersion as a predictor of ventricular arrhythmias was found to be diminished in patients with SSc. Patients with SSc, particularly with higher MR-SSS, should be followed closely for adverse cardiovascular outcomes.
- Open Access
- 18 October 2011
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 16 (4) , 365-372
The Reproducibility of Heart Rate Recovery after Treadmill Exercise Test
Although predictive value of heart rate recovery (HRR) has been tested in large populations, the reproducibility of HRR in treadmill exercise test has not been assessed prospectively. This prospective study examined whether HRR index has test-retest stability in the short term. A total of 52 healthy volunteers without cardiovascular risk factors (mean age, 30 ± 10 years, 30 females) underwent standardized graded treadmill exercise test, and the test was repeated on the 7th and the 30th days. The subjects' maximal heart rates and the decrease of heart rate from the peak exercise level to the level of 1, 2, 3, 4, and 5 minutes after the termination of the exercise were examined on each test, and heart rates for each minute from the first, second, and third tests were compared for each individual. The maximal heart rates on the 1st, 7th, and the 30th days were 179 ± 11, 177 ± 10, 178 ± 10 beats/min, respectively [P = 0.07, intraclass correlation coefficient (ICC) = 0.92], and the 1st minute HRR indices after peak exercise were 33 ± 10, 33 ± 10, 33 ± 11, respectively (P = 0.66, ICC = 0.88). There was no statistical difference in the 2nd, 3rd, 4th, and 5th minute heart rates of the recovery phase among the 1st, 7th, and 30th day treadmill exercise tests, either. Maximal heart rates and the decline of heart rate to the 5th minute on recovery phase after treadmill exercise test have short-term reproducibility.
- 18 October 2011
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 16 (4) , 365-372
Open AccessThe Reproducibility of Heart Rate Recovery after Treadmill Exercise Test
Although predictive value of heart rate recovery (HRR) has been tested in large populations, the reproducibility of HRR in treadmill exercise test has not been assessed prospectively. This prospective study examined whether HRR index has test-retest stability in the short term. A total of 52 healthy volunteers without cardiovascular risk factors (mean age, 30 ± 10 years, 30 females) underwent standardized graded treadmill exercise test, and the test was repeated on the 7th and the 30th days. The subjects' maximal heart rates and the decrease of heart rate from the peak exercise level to the level of 1, 2, 3, 4, and 5 minutes after the termination of the exercise were examined on each test, and heart rates for each minute from the first, second, and third tests were compared for each individual. The maximal heart rates on the 1st, 7th, and the 30th days were 179 ± 11, 177 ± 10, 178 ± 10 beats/min, respectively [P = 0.07, intraclass correlation coefficient (ICC) = 0.92], and the 1st minute HRR indices after peak exercise were 33 ± 10, 33 ± 10, 33 ± 11, respectively (P = 0.66, ICC = 0.88). There was no statistical difference in the 2nd, 3rd, 4th, and 5th minute heart rates of the recovery phase among the 1st, 7th, and 30th day treadmill exercise tests, either. Maximal heart rates and the decline of heart rate to the 5th minute on recovery phase after treadmill exercise test have short-term reproducibility.
- 21 September 2011
- Published by Wiley in International Journal of Rheumatic Diseases
- Vol. 14 (4) , 379-383
Relationship between left ventricular diastolic dysfunction and six minute walk test in patients with systemic sclerosis
Objective: The six minute walk test (6MWT) is used for the assessment of functional capacity in pulmonary and cardiovascular diseases. Left ventricular diastolic dysfunction (LVDD) is the most common cardiac abnormality in systemic sclerosis (SSc). The aim of this study was to define the effect of LVDD on 6MWT parameters in patients with SSc. Methods: We studied 45 (female : male 40 : 5) SSc patients. Patients with obvious conditions that can affect 6MWT distance (6MWD) were excluded. All subjects were evaluated by 6MWT. Additionally, 6MWD of the participants was calculated as the percentage of normal predicted values. LVDD was assessed by using echocardiographic findings and classified into three categories: impaired relaxation, pseudonormal or restrictive. Results: There were 12 (27%) patients with LVDD. SSc patients with LVDD were older than SSc patients without LVDD (50 ± 12 years vs. 41 ± 10 years; P = 0.017). In all, the mean 6MWD was 487.9 ± 98.3 m. The 6MWD was shorter in SSc patients with LVDD as compared to those without LVDD (438.0 ± 94.7 m vs. 506.0 ± 94.5 m; P = 0.039). There was significant difference between the groups regarding the percentage of the predicted 6MWD (74.1 ± 10.1%vs. 82.8 ± 13.1%; P = 0.041). Conclusion: The presence of LVDD alters 6MWD in SSc patients. Reduction of 6MWD in a patient with SSc should prompt the investigation of LVDD.
- 21 September 2011
- Published by Wiley in International Journal of Rheumatic Diseases
- Vol. 14 (4) , 379-383
Relationship between left ventricular diastolic dysfunction and six minute walk test in patients with systemic sclerosis
Objective: The six minute walk test (6MWT) is used for the assessment of functional capacity in pulmonary and cardiovascular diseases. Left ventricular diastolic dysfunction (LVDD) is the most common cardiac abnormality in systemic sclerosis (SSc). The aim of this study was to define the effect of LVDD on 6MWT parameters in patients with SSc. Methods: We studied 45 (female : male 40 : 5) SSc patients. Patients with obvious conditions that can affect 6MWT distance (6MWD) were excluded. All subjects were evaluated by 6MWT. Additionally, 6MWD of the participants was calculated as the percentage of normal predicted values. LVDD was assessed by using echocardiographic findings and classified into three categories: impaired relaxation, pseudonormal or restrictive. Results: There were 12 (27%) patients with LVDD. SSc patients with LVDD were older than SSc patients without LVDD (50 ± 12 years vs. 41 ± 10 years; P = 0.017). In all, the mean 6MWD was 487.9 ± 98.3 m. The 6MWD was shorter in SSc patients with LVDD as compared to those without LVDD (438.0 ± 94.7 m vs. 506.0 ± 94.5 m; P = 0.039). There was significant difference between the groups regarding the percentage of the predicted 6MWD (74.1 ± 10.1%vs. 82.8 ± 13.1%; P = 0.041). Conclusion: The presence of LVDD alters 6MWD in SSc patients. Reduction of 6MWD in a patient with SSc should prompt the investigation of LVDD.