HHHatem Hosny

Hatem Hosny

*This is an algorithmically generated author record based on publicly available information.

Hatem Hosny has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Arrhythmic risk in ventricular cardiac tumors: A comparative imaging and clinical analysis

    by Mohamed S. Riad, Mohamed M. Abdelfadil, Mostafa Wanees Ahmed El Husseny, Taha Abd-ElSalam Ashraf Taha, Eslam Ahmed, Mahmoud Shaaban, Ayman M. Ibrahim, Ahmed Elguindy, Hesham Bahaa, Hatem Hosny, et al.

  • P2789A new technique to restore shape and pattern of flow in hypoplastic aortic arch

    by A Afifi, M Nagy, H Hosny, N Shehata, W Simry, Y Raef, W El Mozy, M Abou Gamrah, H Aguib, M Yacoub

    Background: There is no agreement about the best method for correcting hypoplastic aortic arch in infancy. Residual abnormalities in shape can cause late complications. Patients and methods: We have developed and applied a new method of direct anastomosis of the descending to the ascending aorta to allow for restoration of shape, function and growth. 12 infants undergoing this technique at the age of 61±3months (range 6–28 months) underwent repeat CT 4–15 months after operation. Pre- and post-operative arch width, height and height to width ratio were recorded for all cases. Computerized shape analysis using an in-house tool (developed in MATLAB) was used for processing the 3D segmented shapes of the aortic arch, and assessing changes in the cross-sectional area at different levels. Computational Fluid Dynamics (CFD) was used to simulate aortic flow propagation and pattern after surgery, using patient specific geometry and flow boundary conditions. Results: The pre- and post-operative cross-sectional area along the centerline of the aorta and arch was almost normalized, Figure 1. The pattern of flow during the cardiac cycle with a retrograde helix in the aortic arch, similar to normal, was observed in all cases with peak velocities of 1.1±0.2m/s. Aortic Shape and flow after surgery Conclusion: We here describe a new technique, which at least in the short term appears to normalize the size, shape and pattern of flow in the arch. Long term studies are required to establish the value of this technique.

  • Open Access

    Characterization of size, shape and pattern of flow in the neo-aorta and pulmonary artery in a patient following an innovative technique of repair for truncus arteriosus

    by Amr El Sawy, Mohamed Nagy, Ahmed Afifi, Hatem Hosny, Soha Romeih, Heba Aguib, Magdi Yacoub

    Background. Truncus arteriosus (TA) caries a very poor prognosis. In the absence of early correction, only 12 percent of patients born with this anomaly survive beyond one year. There is no agreement about the best method of surgical correction of this anomaly. We have devised an innovative valveless technique using autologous arterial tissue to repair TA.Objectives. Characterizing the size, shape and pattern of flow in the neo-aorta and pulmonary artery, in a patient following the new technique.Patient and Methods. Cardiac MRI and multislice CT imaging, followed by offline computerized image analysis was used in a patient aged 3 months, within 3 weeks of operating.Results. The size, shape and topology of the neo-aorta and pulmonary artery, approximated that present in normal hearts. The pattern of flow in the reconstructed vessels was laminar, throughout the cardiac cycle with minor acceleration during systole. The pulmonary regurgitation resulting from the absence of a valve occurred during late diastole, and was well tolerated. The size of the right ventricle diminished considerably following operation, and the right ventricular ejection fraction was supernormal.Conclusion. This early study in one patient provides new unique data of the size, shape, topology and pattern of flow in the neo-aorta and pulmonary artery, which appear to approximate normality. The long-term results of this promising operation need to be studied.

  • Predicting the future by looking at the past: necessary but not binding

    by Ahmed Afifi, Hatem Hosny, Magdi Yacoub

    This editorial refers to ‘The ACEF II risk score for cardiac surgery: updated but still parsimonious’, by M. Ranucci et al., doi: 10.1093/eurheartj/ehx228.