Deying Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Deying Chen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Yiqin Ji
Tianjin Jinhang Technical Physics Institute, China
4 shared publicationsHuasong Liu
Tianjin Jinhang Technical Physics Institute, China
3 shared publicationsJie Zong
Tianjin Jinhang Institute of Technical Physics (China)
2 shared publications- Rongwei Fan
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
2 shared publications Yugang Jiang
2 shared publicationsBingjun Wu
Tianjin Jinhang Institute of Technical Physics (China)
1 shared publication
Latest Publications
- 4 February 2021
- Published by IOP Publishing in Laser Physics
- Vol. 31 (3) , 035001
The distortion of laser beams in a burst mode dye laser with 10 kHz repetition rates
In this paper, the distortion of laser beams in the burst of a burst mode dye laser at 10 kHz repetition rates is researched dynamically. The distortion caused by the thermal lens effects is shown when the repetition rates surpass 2.5 kHz, and is observed emerging 100 μ s after the first pulse in the burst. The deflection angles between the laser beams of the first pulse in the burst and each pulse in the burst are measured to describe the distortion. The deflection angles increase to the steady states 400 μ s after the first pulse. The maximum deflection angles increase from 0.5 mrad to 0.85 mrad at 10 kHz with the pump pulse energies increasing from 12 mJ to 30 mJ, and increase from 0.23 mrad to 0.4 mrad at 5 kHz with the pump pulse energies increasing from 12 mJ to 30 mJ. The results show that the distortion increases when the pump pulse energies and the repetition rates of the dye laser increase.
- 4 February 2021
- Published by IOP Publishing in Laser Physics
- Vol. 31 (3) , 035001
The distortion of laser beams in a burst mode dye laser with 10 kHz repetition rates
In this paper, the distortion of laser beams in the burst of a burst mode dye laser at 10 kHz repetition rates is researched dynamically. The distortion caused by the thermal lens effects is shown when the repetition rates surpass 2.5 kHz, and is observed emerging 100 μ s after the first pulse in the burst. The deflection angles between the laser beams of the first pulse in the burst and each pulse in the burst are measured to describe the distortion. The deflection angles increase to the steady states 400 μ s after the first pulse. The maximum deflection angles increase from 0.5 mrad to 0.85 mrad at 10 kHz with the pump pulse energies increasing from 12 mJ to 30 mJ, and increase from 0.23 mrad to 0.4 mrad at 5 kHz with the pump pulse energies increasing from 12 mJ to 30 mJ. The results show that the distortion increases when the pump pulse energies and the repetition rates of the dye laser increase.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 32 (10) , 577-580
High Resolution Image Reconstruction Technology Based on Few Photon Signal of Target
By improving its own gain performance, low light level imaging detection system based on microchannel plate(MCP) can collect weak signals that are difficult to observe by human eyes. However, when the detection system improves its own electronic gain, it will aggravate the image diffusion phenomenon collected by the detection system, which will seriously affect the imaging quality of the detection system. In order to improve the imaging quality of the detection system based on MCP under the experimental condition of high gain, in this paper, we present a high resolution imaging technique based on single photon signals experimentally. Under the condition of high gain, it is difficult for human eyes to recognize the target image acquired by the detection system based on MCP. However, the resolution of the target image can be improved to 28.57lp/mm through the reconstruction technology presentd in this paper.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 32 (10) , 577-580
High Resolution Image Reconstruction Technology Based on Few Photon Signal of Target
By improving its own gain performance, low light level imaging detection system based on microchannel plate(MCP) can collect weak signals that are difficult to observe by human eyes. However, when the detection system improves its own electronic gain, it will aggravate the image diffusion phenomenon collected by the detection system, which will seriously affect the imaging quality of the detection system. In order to improve the imaging quality of the detection system based on MCP under the experimental condition of high gain, in this paper, we present a high resolution imaging technique based on single photon signals experimentally. Under the condition of high gain, it is difficult for human eyes to recognize the target image acquired by the detection system based on MCP. However, the resolution of the target image can be improved to 28.57lp/mm through the reconstruction technology presentd in this paper.
- 1 January 2016
- Published by Optica Publishing Group
- p. ThD.10
Effect of Ion Etching on Polymethyl Methacrylate Surface
The effect of argon ion treatment on PMMA substrate has been studied. The surface topography and roughness was measured by AFM. And optical properties such as spectroscopic ellipsometry, transmittance and reflectance spectra were obtained also.
- 1 January 2016
- Published by Optica Publishing Group
- p. ThD.10
Effect of Ion Etching on Polymethyl Methacrylate Surface
The effect of argon ion treatment on PMMA substrate has been studied. The surface topography and roughness was measured by AFM. And optical properties such as spectroscopic ellipsometry, transmittance and reflectance spectra were obtained also.
- 1 March 2014
- Published by Elsevier in Toxicology Letters
- Vol. 225 (3) , 358-366
UPLC-MS-based serum metabonomics for identifying acute liver injury biomarkers in Chinese miniature pigs
- 1 March 2014
- Published by Elsevier in Toxicology Letters
- Vol. 225 (3) , 358-366
UPLC-MS-based serum metabonomics for identifying acute liver injury biomarkers in Chinese miniature pigs
- 11 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7995, 799502-799502-4
Air-annealing effects on SiO 2 /ITO coating
Indium tin oxide (ITO) thin film with SiO2 protective upper layer prepared by electron beam evaporation was annealed in air up to 300°C. Evolution of transmittance, resistance and surface morphology of this SiO2/ITO coating was studied. Transmittance in visible and near-infrared range both increased while absorption edge exhibited red shift after annealing. Resistance increased monotonously with rising annealing temperature, yet increments became smaller at temperatures above 270°C. Micron-defects were observed on the surface of SiO2/ITO coating after annealing. Enhancement of crystallinity of ITO layer at high temperatures was thought to be responsible for these morphology and resistance evolutions.
- 11 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7995, 799502-799502-4
Air-annealing effects on SiO 2 /ITO coating
Indium tin oxide (ITO) thin film with SiO2 protective upper layer prepared by electron beam evaporation was annealed in air up to 300°C. Evolution of transmittance, resistance and surface morphology of this SiO2/ITO coating was studied. Transmittance in visible and near-infrared range both increased while absorption edge exhibited red shift after annealing. Resistance increased monotonously with rising annealing temperature, yet increments became smaller at temperatures above 270°C. Micron-defects were observed on the surface of SiO2/ITO coating after annealing. Enhancement of crystallinity of ITO layer at high temperatures was thought to be responsible for these morphology and resistance evolutions.
- 1 January 2010
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 8 (S1) , 105-107
Analysis of the magnitude and distribution of low loss thin film
An explicit model from the matrix method is utilized to describe the measurement sensitivity of the photothermal detuning technique dependent on the polarization of the probe beam. Numerical results show that the optimal probe wavelengths and the slope of the main spectral band edges are different for both s- and p-polarized beams with the same incident angle. Compared with the random polarized probe beam at the larger incident angle, the measurement sensitivity can be improved approximately twice over with the p- and s-polarized probe beams under the optimal condition.
- 1 January 2010
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 8 (S1) , 105-107
Analysis of the magnitude and distribution of low loss thin film
An explicit model from the matrix method is utilized to describe the measurement sensitivity of the photothermal detuning technique dependent on the polarization of the probe beam. Numerical results show that the optimal probe wavelengths and the slope of the main spectral band edges are different for both s- and p-polarized beams with the same incident angle. Compared with the random polarized probe beam at the larger incident angle, the measurement sensitivity can be improved approximately twice over with the p- and s-polarized probe beams under the optimal condition.
- 3 July 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7382, 73825E-73825E-5
Low-loss antireflection for laser system
In the laser systems for measurement and so on, like gyro; in its laser cavity or path, it makes use of the optical components which need very high performances, like low loss, low scatter, low reflection, low absorption and high transmittance. In this article, we design and manufacture the 632.8nm(He-Ne laser) low loss AR (LLAR) on crystal quartz, the results show this LLAR have the total loss is about 30ppm and have high uniformity, the fluctuations of the total loss mainly from the surface contamination and the inner defects of crystal material.
- 3 July 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7382, 73825E-73825E-5
Low-loss antireflection for laser system
In the laser systems for measurement and so on, like gyro; in its laser cavity or path, it makes use of the optical components which need very high performances, like low loss, low scatter, low reflection, low absorption and high transmittance. In this article, we design and manufacture the 632.8nm(He-Ne laser) low loss AR (LLAR) on crystal quartz, the results show this LLAR have the total loss is about 30ppm and have high uniformity, the fluctuations of the total loss mainly from the surface contamination and the inner defects of crystal material.
- Open Access
- 1 January 2002
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 51 (5) , 1035-1039
基于OFI椭圆偏振光场等离子体中电离电子能量分布的研究
在准静态隧道电离理论模型和准经典阈上电离理论模型的基础上,建立了一个描述基于光场感生电离的椭圆偏振光场电离电子能量分布的简单模型,推导出了既易于理解又相对简单适用的描述椭圆偏振光场的电子能量分布函数解析表达式.利用此式数值计算了不同偏振参量下的椭圆偏振光场中类钯氙系统的电子能量分布曲线,计算结果表明在相同的激光功率密度下,偏振参量对基于OFI电子碰撞机制的X射线辐射强度是有影响的,并与报道的实验结果一致
- 1 January 2002
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 51 (5) , 1035-1039
Open Access基于OFI椭圆偏振光场等离子体中电离电子能量分布的研究
在准静态隧道电离理论模型和准经典阈上电离理论模型的基础上,建立了一个描述基于光场感生电离的椭圆偏振光场电离电子能量分布的简单模型,推导出了既易于理解又相对简单适用的描述椭圆偏振光场的电子能量分布函数解析表达式.利用此式数值计算了不同偏振参量下的椭圆偏振光场中类钯氙系统的电子能量分布曲线,计算结果表明在相同的激光功率密度下,偏振参量对基于OFI电子碰撞机制的X射线辐射强度是有影响的,并与报道的实验结果一致