RYRyuichi Yada

Ryuichi Yada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryuichi Yada has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Arisa Takeuchi

    Department of Radiation Oncology, Anjo Kosei Hospital , 28 Higashi-Hirokute, Anjo-cho, Anjo City, Aichi 446-8602

    1 shared publication
  • Iori Sumida

    Marketing and Clinical Solutions Accuray Japan K.K. Chiyoda‐ku Tokyo Japan

    1 shared publication
  • Katsumasa Nakamura

    Department of Radiation Oncology Hamamatsu University School of Medicine Hamamatsu Shizuoka Japan

    1 shared publication
  • Katsumasa Nakamura

    Department of Radiation Oncology, Hamamatsu University School of Medicine , 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192

    1 shared publication
  • Keita Sakai

    Department of Radiological Technology, Anjo Kosei Hospital , 28 Higashi-Hirokute, Anjo-cho, Anjo City, Aichi 446-8602

    1 shared publication
  • Ken Shishido

    Department of Radiological Technology, Anjo Kosei Hospital , 28 Higashi-Hirokute, Anjo-cho, Anjo City, Aichi 446-8602

    1 shared publication

Latest Publications

  • Open Access

    High‐accuracy quality control method of CT system couch tops for treatment planning via an advanced 3D coordinate measuring machine

    by Ryuichi Yada, Masataka Sakamoto, Naoya Kurino, Yusuke Ueshima, Tianyuan Wang, Iori Sumida, Katsumasa Nakamura

    Background: Quality control (QC) methods for computed tomography (CT) systems used in treatment planning have not been updated since the release of the Task Group (TG) 66 report by the American Association of Physicists in Medicine (AAPM) in 2003. Conventional QC methods for CT systems fail to fulfill the requirements of high‐precision radiation therapy. Moreover, because the geometric accuracy of CT systems can affect the accuracy of radiation therapy, which is particularly critical in high‐precision radiation therapy, a highly accurate QC method is required. Purpose: This study aimed to develop a high‐accuracy QC method for CT system couch tops suitable for high‐precision radiation therapy by utilizing a wide‐area three‐dimensional (3D) coordinate measuring machine (3D‐CMM), a type of laser tracker. Methods: We used a 3D‐CMM, which includes a wireless probe and a camera unit, focusing on a SOMATOM go.Open Pro CT system. The system was set up in accordance with the reference method outlined in the AAPM TG66 report guidelines. The initial phase verified the accuracy of 3D‐CMM measurement within a CT room using a micrometer. Subsequently, a novel continuous measurement method was developed to enable the real‐time tracking of the couch‐top displacement during travel. This new method was evaluated against the standard manual measurement method. Measurements were performed at 0.1 s intervals at various index positions on the couch top, with and without added weight to simulate the presence of a patient. The gathered data were analyzed to assess the couch‐top displacement, horizontality and orthogonality relative to the imaging plane, providing a comprehensive evaluation of the stability and alignment of the couch top. Results: The difference between the micrometer and measured shifts peaked at 0.08 mm. The continuous measurements agreed with the standard measurements within one standard deviation of the three measurements. The maximum displacements of the couch top were 5.23 and 2.00 mm in the vertical axis, with and without a weight load, respectively. There were differences in the displacement at each measurement point. In the lateral axis, the maximum displacements were 2.05 and 2.09 mm with and without a weight load, respectively. The maximum displacement in the imaging plane was observed at approximately half the distance traveled by the couch top. As the couch top traveled, the horizontal angle in the imaging plane of the couch top varied from 0.06° to 0.07° and 0.25° without a weight load and from 0.09° to 0.21° and 0.34° with a weight. The orthogonal angles of the couch top varied from 0.07° to 0.08° and 0.14° without a weight load and from 0.05° to 0.23° and 0.46° with a weight. Conclusions: The developed QC method for the couch tops of CT systems can evaluate the displacement of the couch top and its horizontality and orthogonality to the imaging plane with detailed submillimeter and subdegree accuracy levels. The high‐accuracy QC of CT systems can improve the accuracy of irradiation in radiation therapy.

  • Open Access

    Comparative analysis of kVCT- and MVCT-guided helical tomotherapy for total body irradiation: evaluation of process times and residual setup errors

    by Yuta Omi, Ryuichi Yada, Tatsuya Hasegawa, Ken Shishido, Keita Sakai, Tomotaka Kinoshita, Katsumasa Nakamura, Yoshiyuki Itoh, Arisa Takeuchi

    Helical tomotherapy-based total body irradiation (TBI) traditionally employs megavoltage computed tomography (MVCT) for image-guided setup; however, its 390 mm field of view (FOV) and long acquisition times constrain workflow efficiency and whole-body alignment. This study evaluated whether a newly implemented whole-body fan-beam kilovoltage CT (kVCT; 500 mm FOV) can streamline this process. In a retrospective study involving 14 patients treated with a Radixact X9 system (September 2021–September 2023), we timed the patient setup, imaging, registration, re-setup, and beam delivery for each upper-body (UB) and lower-body (LB) segment. Residual setup errors were measured along the lateral, longitudinal, and vertical axes. The kVCT shortened the initial setup cycle (setup + imaging + registration) from 25.4 ± 4.6 to 15.9 ± 3.3 min for UB and from 14.5 ± 3.8 to 9.4 ± 2.4 min for LB (P < 0.001 for both). The total fraction time, including delivery time, decreased from 71.8 ± 7.5 to 56.7 ± 5.3 min. When residual errors exceeded 5 mm, the additional time required for a second cycle was nearly halved with kVCT (7.3 vs. 14.3 min for UB; 4.8 vs. 8.2 min for LB). The kVCT maintained mean absolute residual errors below 2 mm in all axes, and every 95th-percentile value remained within the 5 mm tolerance recommended for tomotherapy-based TBI. These time savings are expected to reduce intrafraction motion and staff workload. Overall, whole-body kVCT enables faster, comprehensive image guidance while preserving accuracy, thereby streamlining tomotherapy-based TBI and reducing the burden on patients and clinical staff.