Stephan Maurer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephan Maurer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Peter Kaul
Institute for Safety and Security Research, Hochschule Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany
3 shared publications - Johannes Warmer
Institute of Safety and Security Research ISF, University of Applied Sciences Bonn-Rhine-Sieg, Grantham Allee 20, 53757 Sankt Augustin, Germany
2 shared publications - Christof Hammer
Institute for the Protection of Terrestrial Infrastructures, German Aerospace Center (DLR), Sankt Augustin, Germany
1 shared publication - Christopher Becher
Institute for Safety and Security Research, Hochschule Bonn-Rhein-Sieg, 53359 Rheinbach, Germany
1 shared publication - Jörg Schulenburg
Bundeswehr School of Dog Handling, Gräfin-von-Maltzan-Kaserne, 56766 Ulmen, Germany
1 shared publication - Michaela Schneider
Bundeswehr School of Dog Handling, Gräfin-von-Maltzan-Kaserne, 56766 Ulmen, Germany
1 shared publication
Latest Publications
- Open Access
Investigation of the Impact of Extraneous Odours on the Detection Capability of Explosive Detection Dogs Under a Controlled Test Environment
In this work, an experimental procedure that enables testing of canine detection capabilities is described. The developed testbed includes an experimental setup with six exchangeable detection/sniffing boxes for odour masking experiments as well as an air-conditioned (adjustable temperature and humidity) test environment. This design is used to test the masking effects of petroleum and n-decane in high and low concentrations on the detection probability of targets containing technical-grade TNT on explosive detection dogs. The potential influence of the masking agents at different concentrations was investigated with eight canines and, in total, more than 1250 test runs. Within the limits of this investigation, no negative impact of the masking agent on the canine detection capabilities (probability of the successful detection of the target) could be found.
Open AccessInvestigation of the Impact of Extraneous Odours on the Detection Capability of Explosive Detection Dogs Under a Controlled Test Environment
In this work, an experimental procedure that enables testing of canine detection capabilities is described. The developed testbed includes an experimental setup with six exchangeable detection/sniffing boxes for odour masking experiments as well as an air-conditioned (adjustable temperature and humidity) test environment. This design is used to test the masking effects of petroleum and n-decane in high and low concentrations on the detection probability of targets containing technical-grade TNT on explosive detection dogs. The potential influence of the masking agents at different concentrations was investigated with eight canines and, in total, more than 1250 test runs. Within the limits of this investigation, no negative impact of the masking agent on the canine detection capabilities (probability of the successful detection of the target) could be found.
- Open Access
- 5 November 2020
- Published by MDPI AG in Electronics
- Vol. 9 (11) , 1855
A Compact 16 Channel Embedded System with High Dynamic Range Readout and Heater Management for Semiconducting Metal Oxide Gas Sensors
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100 to 5 G (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.- 5 November 2020
- Published by MDPI AG in Electronics
- Vol. 9 (11) , 1855
Open AccessA Compact 16 Channel Embedded System with High Dynamic Range Readout and Heater Management for Semiconducting Metal Oxide Gas Sensors
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100 to 5 G (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance. - 1 August 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 215, 70-76
Fast testing for explosive properties of mg-scale samples by thermal activation and classification by physical and chemical properties
- 1 August 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 215, 70-76
Fast testing for explosive properties of mg-scale samples by thermal activation and classification by physical and chemical properties