Alessandro Russo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alessandro Russo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Maurilio Marcacci
IRCCS Humanitas Research Hospital Rozzano Milan Italy
5 shared publications - Andrea Visani
Surgical Sciences and Technologies Rizzoli Orthopaedic Institute Bologna Italy
3 shared publications - Marco Boi
Scienze e Tecnologie Biomediche e Nanobiotecnologie, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
2 shared publications - Nicola Francesco Lopomo
Department of Design, Politecnico di Milano, Milan, Italy
2 shared publications - Stefano Zaffagnini
Clinica Ortopedica e Traumatologica II, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
2 shared publications - Valentin Alek Dediu
ISMN-CNR, Bologna, Italy
2 shared publications
Latest Publications
- Open Access
- 1 August 2020
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2020 (8) , rjaa274
The effect of autologous adipose derived mesenchymal stem cell therapy on juvenile osteochondritis dissecans of the patella: a case study
A prospective analysis of the effect of autologous adipose derived mesenchymal stem cell (AD-MSCs) therapy in the treatment of a juvenile osteochondritis dissecans (JOCD) of the patella. After failed conventional management of JOCD, a 13-year-old patient undergoes intra-articular MSC therapy. Repeated magnetic resonance imaging analyses showed regeneration of cartilage. In this report, the use of AD-MSCs, after unsuccessful conventional JOCD management, resulted in structural, functional and pain improvement. These results highlight the possibility to avoid surgery treatment in JOCD patella treatment.
- 1 August 2020
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2020 (8) , rjaa274
Open AccessThe effect of autologous adipose derived mesenchymal stem cell therapy on juvenile osteochondritis dissecans of the patella: a case study
A prospective analysis of the effect of autologous adipose derived mesenchymal stem cell (AD-MSCs) therapy in the treatment of a juvenile osteochondritis dissecans (JOCD) of the patella. After failed conventional management of JOCD, a 13-year-old patient undergoes intra-articular MSC therapy. Repeated magnetic resonance imaging analyses showed regeneration of cartilage. In this report, the use of AD-MSCs, after unsuccessful conventional JOCD management, resulted in structural, functional and pain improvement. These results highlight the possibility to avoid surgery treatment in JOCD patella treatment.
- Open Access
- 1 April 2016
- Published by Georg Thieme Verlag KG in Joints
- Vol. 04 (02) , 121-125
Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis
Purpose: dinamic roentgen stereophotogrammetric analysis (RSA), a technique currently based only on customized radiographic equipment, has been shown to be a very accurate method for detecting threedimensional (3D) joint motion. The aim of the present work was to evaluate the applicability of an innovative RSA set-up for in vivo knee kinematic analysis, using a biplane fluoroscopic image system. To this end, the Authors describe the set-up as well as a possible protocol for clinical knee joint evaluation. The accuracy of the kinematic measurements is assessed. Methods: the Authors evaluated the accuracy of 3D kinematic analysis of the knee in a new RSA set-up, based on a commercial biplane fluoroscopy system integrated into the clinical environment. The study was organized in three main phases: an in vitro test under static conditions, an in vitro test under dynamic conditions reproducing a flexion-extension range of motion (ROM), and an in vivo analysis of the flexionextension ROM. For each test, the following were calculated, as an indication of the tracking accuracy: mean, minimum, maximum values and standard deviation of the error of rigid body fitting. Results: in terms of rigid body fitting, in vivo test errors were found to be 0.10±0.05 mm. Phantom tests in static and kinematic conditions showed precision levels, for translations and rotations, of below 0.1 mm/0.2º and below 0.5 mm/0.3º respectively for all directions. Conclusions: the results of this study suggest that kinematic RSA can be successfully performed using a standard clinical biplane fluoroscopy system for the acquisition of slow movements of the lower limb. Clinical relevance: a kinematic RSA set-up using a clinical biplane fluoroscopy system is potentially applicable and provides a useful method for obtaining better characterization of joint biomechanics.
- 1 April 2016
- Published by Georg Thieme Verlag KG in Joints
- Vol. 04 (02) , 121-125
Open AccessEvaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis
Purpose: dinamic roentgen stereophotogrammetric analysis (RSA), a technique currently based only on customized radiographic equipment, has been shown to be a very accurate method for detecting threedimensional (3D) joint motion. The aim of the present work was to evaluate the applicability of an innovative RSA set-up for in vivo knee kinematic analysis, using a biplane fluoroscopic image system. To this end, the Authors describe the set-up as well as a possible protocol for clinical knee joint evaluation. The accuracy of the kinematic measurements is assessed. Methods: the Authors evaluated the accuracy of 3D kinematic analysis of the knee in a new RSA set-up, based on a commercial biplane fluoroscopy system integrated into the clinical environment. The study was organized in three main phases: an in vitro test under static conditions, an in vitro test under dynamic conditions reproducing a flexion-extension range of motion (ROM), and an in vivo analysis of the flexionextension ROM. For each test, the following were calculated, as an indication of the tracking accuracy: mean, minimum, maximum values and standard deviation of the error of rigid body fitting. Results: in terms of rigid body fitting, in vivo test errors were found to be 0.10±0.05 mm. Phantom tests in static and kinematic conditions showed precision levels, for translations and rotations, of below 0.1 mm/0.2º and below 0.5 mm/0.3º respectively for all directions. Conclusions: the results of this study suggest that kinematic RSA can be successfully performed using a standard clinical biplane fluoroscopy system for the acquisition of slow movements of the lower limb. Clinical relevance: a kinematic RSA set-up using a clinical biplane fluoroscopy system is potentially applicable and provides a useful method for obtaining better characterization of joint biomechanics.
- Open Access
- 1 January 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 58, 381-388
Optimizing thickness of ceramic coatings on plastic components for orthopedic applications: A finite element analysis
- 1 January 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 58, 381-388
Open AccessOptimizing thickness of ceramic coatings on plastic components for orthopedic applications: A finite element analysis
- 12 October 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (05) , 1550070
NANOMECHANICAL CHARACTERIZATION OF ZIRCONIA THIN FILMS DEPOSITED ON UHMWPE BY PULSED PLASMA DEPOSITION
Plastic deformation and wear of the ultra-high molecular weight polyethylene (UHMWPE) insert have been pointed out as major issues relating to the long-term stability of an orthopaedic implant. The deposition of protective hard, tough and well-adhered zirconia ( ZrO2) thin films directly on the surface of the UHMWPE component via the Pulsed Plasma Deposition (PPD) technique has been already demonstrated to be a feasible way to approach this problem. In the current study, the tribo-mechanical properties of ZrO2-coated UHMWPE with respect to pristine UHMWPE were investigated in detail. Specifically, strength to local plastic deformation, indentation work portioning and creep behavior were evaluated through nanoindentation and micro-scratch tests. Further, preliminary wear data (i.e., rate and volume) were obtained by tribology tests mating coated and pristine UHMWPE with an alumina ball under dry conditions. The results of the mechanical tests evidenced a strong reduction of plastic deformation under both normal and tangential local loads and a drop of the 80% of the creep phenomenon for coated UHMWPE compared to pristine UHMWPE. Despite tribological tests showed similar wear data for coated and pristine UHMWPE, a different wear mechanism was detected between the two groups. The reported results supported the possibility to pursue this novel approach of depositing ZrO2thin film to protect the UHWMPE insert and enhance the long-term stability of the orthopaedic implants.
- 12 October 2015
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 15 (05) , 1550070
NANOMECHANICAL CHARACTERIZATION OF ZIRCONIA THIN FILMS DEPOSITED ON UHMWPE BY PULSED PLASMA DEPOSITION
Plastic deformation and wear of the ultra-high molecular weight polyethylene (UHMWPE) insert have been pointed out as major issues relating to the long-term stability of an orthopaedic implant. The deposition of protective hard, tough and well-adhered zirconia ( ZrO2) thin films directly on the surface of the UHMWPE component via the Pulsed Plasma Deposition (PPD) technique has been already demonstrated to be a feasible way to approach this problem. In the current study, the tribo-mechanical properties of ZrO2-coated UHMWPE with respect to pristine UHMWPE were investigated in detail. Specifically, strength to local plastic deformation, indentation work portioning and creep behavior were evaluated through nanoindentation and micro-scratch tests. Further, preliminary wear data (i.e., rate and volume) were obtained by tribology tests mating coated and pristine UHMWPE with an alumina ball under dry conditions. The results of the mechanical tests evidenced a strong reduction of plastic deformation under both normal and tangential local loads and a drop of the 80% of the creep phenomenon for coated UHMWPE compared to pristine UHMWPE. Despite tribological tests showed similar wear data for coated and pristine UHMWPE, a different wear mechanism was detected between the two groups. The reported results supported the possibility to pursue this novel approach of depositing ZrO2thin film to protect the UHWMPE insert and enhance the long-term stability of the orthopaedic implants.
- 1 June 2015
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 61, 101-106
Application of magnetic rods for fixation in orthopedic treatments
- 1 June 2015
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 61, 101-106
Application of magnetic rods for fixation in orthopedic treatments
- 17 October 2013
- Published by Elsevier in BioSystems
- Vol. 114 (3) , 227-237
In silico prediction of the cell proliferation in porous scaffold using model of effective pore
- 17 October 2013
- Published by Elsevier in BioSystems
- Vol. 114 (3) , 227-237
In silico prediction of the cell proliferation in porous scaffold using model of effective pore