GPGrégoire Pichenot

Grégoire Pichenot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Grégoire Pichenot has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Online Production Management of a District Heating Network via an Approximate Explicit Model Predictive Control: Toward an Implementable Solution

    by Zinedine Taieb, Guillaume Sandou, Nicolas Vasset, Yacine Gaoua, Grégoire Pichenot

    Achieving sustainable energy system deployment requires efficient real-time supervision, which can be supported by Energy Management System (EMS) control units. Although advanced optimal techniques %can enable promising performanceare promising, they often rely on significant computational resources which may constitute deployment barriers to the integration of intelligent control strategies, especially onto small local systems. This article proposes an Approximate Explicit (AE) method, aiming to surrogate Mixed-Integer Linear Programming (MILP) optimization problems in the deployment phase. From that, an Approximate Explicit Model Predictive Control (AEMPC) controller is derived through a data-driven procedure exploiting the explicit mathematical structure of the MILP problem, notably by approximating the optimal control law within a multiparametric programming (mp-P) framework. Throughout this article, a progressive workflow is developed to address the mathematical, operational, simulation, and computational challenges associated with implementing the AEMPC strategy. Notably, the method is applied to the energy production planning of a small-scaled District Heating Network (DHN) inspired of a real-world experimental DHN platform. The resulting AEMPC reproduces the conventional MPC behavior while deployment computational requirements are significantly reduced.

  • Open Access

    Online Production Management of a District Heating Network via an Approximate Explicit Model Predictive Control: Toward an Implementable Solution

    by Zinedine Taieb, Guillaume Sandou, Nicolas Vasset, Yacine Gaoua, Grégoire Pichenot

    Achieving sustainable energy system deployment requires efficient real-time supervision, which can be supported by Energy Management System (EMS) control units. Although advanced optimal techniques %can enable promising performanceare promising, they often rely on significant computational resources which may constitute deployment barriers to the integration of intelligent control strategies, especially onto small local systems. This article proposes an Approximate Explicit (AE) method, aiming to surrogate Mixed-Integer Linear Programming (MILP) optimization problems in the deployment phase. From that, an Approximate Explicit Model Predictive Control (AEMPC) controller is derived through a data-driven procedure exploiting the explicit mathematical structure of the MILP problem, notably by approximating the optimal control law within a multiparametric programming (mp-P) framework. Throughout this article, a progressive workflow is developed to address the mathematical, operational, simulation, and computational challenges associated with implementing the AEMPC strategy. Notably, the method is applied to the energy production planning of a small-scaled District Heating Network (DHN) inspired of a real-world experimental DHN platform. The resulting AEMPC reproduces the conventional MPC behavior while deployment computational requirements are significantly reduced.

  • STATISTICAL STUDY OF ECT DETECTION AROUND FASTENERS USING SIMULATION BASED POD CURVES

    by C. Reboud, G. Pichenot, S. Paillard, F. Jenson, Donald O. Thompson, Dale E. Chimenti

    Calculation of Probability of Detection (POD) curves based on simulation results are presented in the case of the Eddy Current Testing (ECT) configurations involving a flaw buried inside a riveted structure. In order to overcome some accuracy limitations and to optimize calculation speed, the semi‐analytical model used in simulation has been improved in order to handle separate discretizations of objects. New possibilities consecutive to this development are presented, as well as two parametric models used for the computation of interactive POD curves with the CIVA software.


  • Development of a 3D Electromagnetic Model for Eddy Current Tubing Inspection: Application to Steam Generator Tubing

    by G. Pichenot, D. Prémel, T. Sollier, V. Maillot

    In nuclear plants, the inspection of heat exchanger tubes is usually carried out by using eddy current nondestructive testing. A numerical model, based on a volume integral approach using the Green’s dyadic formalism, has been developed, with support from the French Institute for Radiological Protection and Nuclear Safety, to predict the response of an eddy current bobbin coil to 3D flaws located in the tube’s wall. With an aim of integrating this model into the NDE multi techniques platform CIVA, it has been validated with experimental data for 2D and 3D flaws.