Geraldo R. M. da Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Geraldo R. M. da Costa has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guilherme Guimarães Lage
Electrical Engineering Department, Federal University of So Carlos, So Carlos, Brazil
2 shared publications - Anderson Marcos de Souza
Universidade de Brasília, Brasil
1 shared publication Dilson A. Alves
Electrical Engineering Department, FEIS, UNESP – São Paulo State University, Brazil
1 shared publication- Edmarcio Antonio Belati
Center for Engineering, Modeling and Applied Social Sciences (CECS), Federal University of ABC, Santo André 09210-170, SP, Brazil
1 shared publication - Ricardo Bento Nogueira Mori Pinheiro
Department of Electrical and Computer Engineering, University of São Paulo, 400 Trabalhador São-carlense Av., São Carlos, 13566-590 SP, Brazil
1 shared publication Vanusa A. de Sousa
Department of Electrical Engineering, Engineering School of São Carlos, University of São Paulo, São Carlos, SP, Brazil
1 shared publication
Latest Publications
- 1 August 2019
- Published by Elsevier in European Journal of Operational Research
- Vol. 276 (3) , 1137-1153
A primal-dual integrated nonlinear rescaling approach applied to the optimal reactive dispatch problem
- 1 August 2019
- Published by Elsevier in European Journal of Operational Research
- Vol. 276 (3) , 1137-1153
A primal-dual integrated nonlinear rescaling approach applied to the optimal reactive dispatch problem
- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. rrr 12 94, 1-6
Optimal power flow solution using the penalty/modified barrier method
The solution of the optimal power flow problem through the penalty/modified barrier method is described in this paper. This approach features considerable advantages over interior point methods. In this method, the inequality constraints are transformed into equalities by the introduction of slack variables, which are handled by either the modified barrier function or the quadratic penalty function. Then, first order optimality conditions and Newton's method are applied in the solution of the problem. In order to validate the proposed method, electrical power systems of 3, 14, 30, 118, 162 and 300 buses were used as case studies, and the obtained results proved the method's efficiency.
- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. rrr 12 94, 1-6
Optimal power flow solution using the penalty/modified barrier method
The solution of the optimal power flow problem through the penalty/modified barrier method is described in this paper. This approach features considerable advantages over interior point methods. In this method, the inequality constraints are transformed into equalities by the introduction of slack variables, which are handled by either the modified barrier function or the quadratic penalty function. Then, first order optimality conditions and Newton's method are applied in the solution of the problem. In order to validate the proposed method, electrical power systems of 3, 14, 30, 118, 162 and 300 buses were used as case studies, and the obtained results proved the method's efficiency.
- 1 September 2008
- Published by Elsevier in Electric Power Systems Research
- Vol. 78 (9) , 1553-1560
An approach of optimal sensitivity applied in the tertiary loop of the automatic generation control
- 1 September 2008
- Published by Elsevier in Electric Power Systems Research
- Vol. 78 (9) , 1553-1560
An approach of optimal sensitivity applied in the tertiary loop of the automatic generation control
- 1 January 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 844-848 Vol.1
Optimal power flow: a tool for managing the transmission congestion
This paper presents a study of the Lagrange multipliers in congested transmission systems. The Lagrange multiplier indicates the sensitivity of constraints related with the objective function. The Lagrange multipliers are obtained via optimal power flow with transmission constraints. Optimal power flow problem is solved by primal-dual logarithmic barrier method. The results obtained in networks (53 and 118 bus) show that the proposed technique is able to improve system planning.
- 1 January 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 844-848 Vol.1
Optimal power flow: a tool for managing the transmission congestion
This paper presents a study of the Lagrange multipliers in congested transmission systems. The Lagrange multiplier indicates the sensitivity of constraints related with the objective function. The Lagrange multipliers are obtained via optimal power flow with transmission constraints. Optimal power flow problem is solved by primal-dual logarithmic barrier method. The results obtained in networks (53 and 118 bus) show that the proposed technique is able to improve system planning.
- 1 December 2002
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 24 (10) , 815-819
Modified Newton method for reactive dispatching
- 1 December 2002
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 24 (10) , 815-819
Modified Newton method for reactive dispatching