SSSuppachai Sinthaworn

Suppachai Sinthaworn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suppachai Sinthaworn has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Estimation of Ultimate Tensile Strength of dentin Using Finite Element Analysis from Endodontically Treated Tooth

    by S Sinthaworn, U Puengpaiboon, N Warasetrattana, S Wanapaisarn

    Endodontically treated teeth were simulated by finite element analysis in order to estimate ultimate tensile strength of dentin. Structures of the endodontically treated tooth cases are flared root canal, restored with different number of fiber posts {i.e. resin composite core without fiber post (group 1), fiber post No.3 with resin composite core (group 2) and fiber post No.3 accessory 2 fiber posts No.0 with resin composite core (group 3)}. Elastic modulus and Poisson's ratio of materials were selected from literatures. The models were loaded by the average fracture resistances load of each groups (group 1: 361.80 N, group 2: 559.46 N, group 3: 468.48 N) at 135 degree angulation in respect to the longitudinal axis of the teeth. The stress analysis and experimental confirm that fracture zone is at dentin area. To estimate ultimate tensile strength of dentin, trial and error of ultimate tensile strength were tested to obtain factor of safety (FOS) equal to 1.00. The result reveals that ultimate tensile strength of dentin of group 1, 2, 3 are 38.89, 30.96, 37.19 MPa, respectively.


  • Water Penetration Resistance of Green Concrete Incorporating with Quarry Wastes

    by Suppachai Sinthaworn, Wasan Teerajetgul, Attasit Sirivachiraporn

    In this study, the workability, the compressive strength and the water penetration depth under pressure for concrete incorporate with quarry waste as fine aggregate were investigated. The mix proportions of concrete were set into two classes of water to cement ratio (w/c = 0.4, 0.6). The first class (C1), the mix proportion is 1.0:0.6:2.0:4.0 (Cement: Water: Fine: Coarse). And the second class (C2), the mix proportion is 1.0:0.4:1.5:3.0 and adding the superplasticizer 1% of cement weight. The natural river sand, which use in concrete, was partially replaced by quarry dust at the rates of 0% (no quarry dust), 50% and 100 % by weight of fine aggregate. The results show that concrete containing quarry wastes as fine aggregate decreased the workability and do not significantly affect the 28-day compressive strength whereas concrete incorporating with quarry dusts reduces the water penetration depth.