Amir A. Naqwi
Amir A. Naqwi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Chris Fandrey
Powerscope Incorporated, 1313 Fifth Street SE, Suite 209, Minneapolis, MN 55414
1 shared publication- Franz Durst
Institute of Fluid Mechanics (LSTM-Erlangen), University of Erlangen-Nuremberg , Cauerstr. 4, 91058 Erlangen
1 shared publication - Guifang Zhang
Guangdong Key Laboratory for Translational Cancer Research of Chinese Medicine, Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People’s Republic of China, International Institute for Translational Chinese Medicine, School of Pharmaceutical Science, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
1 shared publication - Timothy Scott Wiedmann
Department of Pharmaceutics, University of Minnesota, Minneapolis, Minnesota 55455, USA
1 shared publication Xiao‐Z. Liu
Lehrstuhl für Strömungsmechanik, University of Erlangen, Cauerstraße 4, D-8520 Erlangen (Federal Republic of Germany)
1 shared publication
Latest Publications
- Open Access
- 1 January 2008
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 34 (5) , 209-223
HIGH-FREQUENCY ULTRASONIC ATOMIZATION FOR DRUG DELIVERY TO RODENT ANIMAL MODELS—OPTIMAL PARTICLE SIZE FOR LUNG INHALATION OF DIFLUOROMETHYL ORNITHINE
A high-(8-MHz) and a low-(1.7-MHz) frequency ultrasonic transducer were compared for delivering aerosols to mouse lung. The aerosol concentration (mass of dry particles/volume of air) rose nonlinearly with solution concentration of difluoromethyl ornithine for both transducers. The particle size was linear with the cube root of the solution concentration, and the slope of the low-frequency transducer was 8 times greater than that of the high-frequency transducer. The deposition fraction assessed by the assayed mass in the lung relative to the calculated inhaled mass was found to decline exponentially with particle size. The lower-frequency transducer provided a higher dose despite a lower deposition fraction, but the high-frequency transducer was more efficient and provides a more selective deposition in the lower respiratory tract while operating with significantly less demands on aerosol drying.
- 1 January 2008
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 34 (5) , 209-223
Open AccessHIGH-FREQUENCY ULTRASONIC ATOMIZATION FOR DRUG DELIVERY TO RODENT ANIMAL MODELS—OPTIMAL PARTICLE SIZE FOR LUNG INHALATION OF DIFLUOROMETHYL ORNITHINE
A high-(8-MHz) and a low-(1.7-MHz) frequency ultrasonic transducer were compared for delivering aerosols to mouse lung. The aerosol concentration (mass of dry particles/volume of air) rose nonlinearly with solution concentration of difluoromethyl ornithine for both transducers. The particle size was linear with the cube root of the solution concentration, and the slope of the low-frequency transducer was 8 times greater than that of the high-frequency transducer. The deposition fraction assessed by the assayed mass in the lung relative to the calculated inhaled mass was found to decline exponentially with particle size. The lower-frequency transducer provided a higher dose despite a lower deposition fraction, but the high-frequency transducer was more efficient and provides a more selective deposition in the lower respiratory tract while operating with significantly less demands on aerosol drying.
- 1 January 1992
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 9 (1-4) , 44-51
Evaluation of the Dual‐Cylindrical Wave Laser Technique for sizing of liquid droplets
The newly developed dual‐cylindrical wave laser system is an alternative to the phase Doppler technique. It requires only frequency measurements for particle sizing and velocimetry, and hence prevents the difficulties associated with the phase measurements. This technique was evaluated experimentally using monosize liquid droplets of water and diethyl phthalate. The experimental results are compared with the theoretical predictions of the system response, based on geometrical optics and the electromagnetic theory of light, under certain simplifying assumptions. Although the measurements generally agree with the theory, some minor oscillations in the measured response are only roughly represented by the theory. Also, the experimental data indicate a large deviation from the theory if the particle is within a distance of three diameters from the origin of the cylindrical waves, hence defining the boundary of the region in which the theory is applicable. This work indicates that a properly laid out dual‐cylindrical wave laser system can be employed for sizing of small droplets in liquid sprays.
- 1 January 1992
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 9 (1-4) , 44-51
Evaluation of the Dual‐Cylindrical Wave Laser Technique for sizing of liquid droplets
The newly developed dual‐cylindrical wave laser system is an alternative to the phase Doppler technique. It requires only frequency measurements for particle sizing and velocimetry, and hence prevents the difficulties associated with the phase measurements. This technique was evaluated experimentally using monosize liquid droplets of water and diethyl phthalate. The experimental results are compared with the theoretical predictions of the system response, based on geometrical optics and the electromagnetic theory of light, under certain simplifying assumptions. Although the measurements generally agree with the theory, some minor oscillations in the measured response are only roughly represented by the theory. Also, the experimental data indicate a large deviation from the theory if the particle is within a distance of three diameters from the origin of the cylindrical waves, hence defining the boundary of the region in which the theory is applicable. This work indicates that a properly laid out dual‐cylindrical wave laser system can be employed for sizing of small droplets in liquid sprays.