Sunil Shetty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sunil Shetty has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hagen Schmal
Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
5 shared publications - Michael Seidenstuecker
G.E.R.N. Center of Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg Medical Center, Freiburg, Germany
5 shared publications - Martin Pichotka
Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, 79106 Freiburg, Germany
4 shared publications - Bernd Rolauffs
G.E.R.N. Research Center for Tissue Replacement Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Faculty of Medicine Medical Center‐Albert‐Ludwigs‐University of Freiburg Freiburg im Breisgau Germany
2 shared publications - Ralf Thomann
Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), University of Freiburg, Georges-Köhler-Allee 105, 79110 Freiburg, Germany
2 shared publications Bianca Riedel
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 538
Technical Feasibility of an Ex Vivo Bovine Trabecular Bone-Titanium Implant Co-Culture Platform for Early Interface Studies
Ex vivo bone organ cultures may bridge the gap between simplified in vitro systems and animal studies. This proof-of-concept study evaluated the technical feasibility of a bovine trabecular bone–implant co-culture platform over 21 days. Thirty-two bone cylinders from three donors were cultured with porous Ti6Al4V implants. A central 6 mm channel reduced the maximum theoretical radial diffusion distance to approximately 2.5 mm. Wurtzite and diamond architectures were coupled to experimental run and femoral laterality, precluding independent evaluation of architecture-dependent biological effects. Constructs received no load, sustained static load, or static load combined with daily or weekly dynamic compression at 1 Hz for 300 cycles per session. Loaded assemblies comprised four constructs beneath a shared plate; individual forces, stresses, and strains were neither measured nor independently controlled. Metabolic activity, viability, histology, bone volume fraction, immunofluorescence, and implant colonization were assessed. Structural comparisons were cross-sectional. Metabolic activity initially decreased before increasing from day 7 onward, and viable cells and extensive implant colonization were observed after 21 days. No loading-dependent biological or structural differences were detected. The findings support technical feasibility but do not establish mechanobiological sensitivity. Further validation requires specimen-specific mechanical monitoring, re-optimization of loading parameters, and quantitative biological endpoints.
- 23 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 538
Open AccessTechnical Feasibility of an Ex Vivo Bovine Trabecular Bone-Titanium Implant Co-Culture Platform for Early Interface Studies
Ex vivo bone organ cultures may bridge the gap between simplified in vitro systems and animal studies. This proof-of-concept study evaluated the technical feasibility of a bovine trabecular bone–implant co-culture platform over 21 days. Thirty-two bone cylinders from three donors were cultured with porous Ti6Al4V implants. A central 6 mm channel reduced the maximum theoretical radial diffusion distance to approximately 2.5 mm. Wurtzite and diamond architectures were coupled to experimental run and femoral laterality, precluding independent evaluation of architecture-dependent biological effects. Constructs received no load, sustained static load, or static load combined with daily or weekly dynamic compression at 1 Hz for 300 cycles per session. Loaded assemblies comprised four constructs beneath a shared plate; individual forces, stresses, and strains were neither measured nor independently controlled. Metabolic activity, viability, histology, bone volume fraction, immunofluorescence, and implant colonization were assessed. Structural comparisons were cross-sectional. Metabolic activity initially decreased before increasing from day 7 onward, and viable cells and extensive implant colonization were observed after 21 days. No loading-dependent biological or structural differences were detected. The findings support technical feasibility but do not establish mechanobiological sensitivity. Further validation requires specimen-specific mechanical monitoring, re-optimization of loading parameters, and quantitative biological endpoints.
- Open Access
- 16 September 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (5) , 055007
Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing
Degenerative disc disease remains a primary cause of chronic back pain, yet current surgical treatments are often limited by the mechanical mismatch between implants and native intervertebral disc (IVD) tissue. This study investigates additively manufactured functionally graded Gyroid structures based on thermoplastic polyurethane (TPU) as biomimetic IVD replacements, focusing on the influence of geometry and material gradients on mechanical performance. Gyroid-based constructs were fabricated by multi-material fused filament fabrication using TPU filaments of different stiffness. Their mechanical performance was evaluated under static and dynamic compressive loading. Finite element analysis was performed to investigate stress distribution within the Gyroid architecture, while micro-computed tomography (µCT) was used to assess manufacturing-related defects and structural integrity before and after 700 000 loading cycles. All investigated structures exhibited stable and reproducible mechanical behavior. However, only a single geometric configuration reached the targeted physiological load range of 4000–8000 N, irrespective of the material combination. The incorporation of an additional compliant TPU phase did not significantly alter the global force–deformation response compared with two-material configurations, indicating that structural geometry predominantly governs the compressive mechanical behavior. Dynamic testing demonstrated consistent damping capacities of approximately 20% across all configurations together with stable stiffness, storage modulus, and loss modulus during fatigue loading. Finite element analysis revealed homogeneous load distribution with localized stress concentrations at the curved Gyroid junctions. Quantitative µCT analysis showed no measurable increase in micro-porosity, void fraction, or interfacial defects after 600 000 loading cycles. The findings demonstrate that the mechanical performance of TPU-based Gyroid IVD constructs is primarily governed by architectural design rather than material gradients under compressive loading. The combined experimental, numerical, and µCT analyses confirm the mechanical robustness and structural stability of the proposed functionally graded Gyroid structures, highlighting architecture-driven design as a promising strategy for mechanically compatible IVD replacements.
- 16 September 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (5) , 055007
Open AccessBioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing
Degenerative disc disease remains a primary cause of chronic back pain, yet current surgical treatments are often limited by the mechanical mismatch between implants and native intervertebral disc (IVD) tissue. This study investigates additively manufactured functionally graded Gyroid structures based on thermoplastic polyurethane (TPU) as biomimetic IVD replacements, focusing on the influence of geometry and material gradients on mechanical performance. Gyroid-based constructs were fabricated by multi-material fused filament fabrication using TPU filaments of different stiffness. Their mechanical performance was evaluated under static and dynamic compressive loading. Finite element analysis was performed to investigate stress distribution within the Gyroid architecture, while micro-computed tomography (µCT) was used to assess manufacturing-related defects and structural integrity before and after 700 000 loading cycles. All investigated structures exhibited stable and reproducible mechanical behavior. However, only a single geometric configuration reached the targeted physiological load range of 4000–8000 N, irrespective of the material combination. The incorporation of an additional compliant TPU phase did not significantly alter the global force–deformation response compared with two-material configurations, indicating that structural geometry predominantly governs the compressive mechanical behavior. Dynamic testing demonstrated consistent damping capacities of approximately 20% across all configurations together with stable stiffness, storage modulus, and loss modulus during fatigue loading. Finite element analysis revealed homogeneous load distribution with localized stress concentrations at the curved Gyroid junctions. Quantitative µCT analysis showed no measurable increase in micro-porosity, void fraction, or interfacial defects after 600 000 loading cycles. The findings demonstrate that the mechanical performance of TPU-based Gyroid IVD constructs is primarily governed by architectural design rather than material gradients under compressive loading. The combined experimental, numerical, and µCT analyses confirm the mechanical robustness and structural stability of the proposed functionally graded Gyroid structures, highlighting architecture-driven design as a promising strategy for mechanically compatible IVD replacements.
- Open Access
- 11 September 2026
- Published by Elsevier in SSRN Electronic Journal
Material-Architecture Interactions Govern the Static and Cyclic Behavior of Additively Manufactured PEBA Gyroids for Intervertebral Disc Replacement
Polyether block amide (PEBA) is a potential material for additively manufactured intervertebral disc replacement concepts. We investigated how material properties, printing accuracy, and Gyroid architecture affect the static and cyclic compressive behavior of fused-filament-fabricated PEBA structures. Three commercial PEBA filaments were printed as twelve Gyroid geometries with cell sizes of 4–10 mm and nominal wall thicknesses of 0.50–1.00 mm. Seven material–geometry combinations were subjected to 700,000 loading cycles at 5 Hz between -600 and -2,000 N. Tensile moduli ranged from 18.82 to 38.41 MPa and yield stresses from 6.93 to 11.68 MPa, demonstrating that manufacturer-specified hardness did not predict the mechanical ranking. Several configurations reached the predefined force corridor of 4,000–8,000 N, and all cyclically tested specimens completed loading without macroscopic failure. However, load-bearing and dissipative properties evolved differently. Spectrum #08 showed pronounced decreases in loss modulus and tan δ despite increased structural stiffness. Immediately after loading, height retention ranged from 94.9% to 96.6%. After 24 h, it ranged from 95.9% to 98.2%, with significant recovery for Spectrum and Siraya Tech but not SainSmart. Paired micro-computed tomography of contrasting Spectrum #06 and #08 specimens showed preservation of the Gyroid architecture, although #08 exhibited greater localized changes in gap-closing sensitivity. Finite element analysis identified material-dependent stress magnitudes localized at curved Gyroid junctions. Overall, PEBA Gyroid mechanics were governed by material–manufacturing–architecture interactions rather than nominal hardness alone. PEBA represents a promising mechanically adaptable platform, although medical-grade materials, biological validation, and multi-specimen structural analyses are required before translation.
- 11 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMaterial-Architecture Interactions Govern the Static and Cyclic Behavior of Additively Manufactured PEBA Gyroids for Intervertebral Disc Replacement
Polyether block amide (PEBA) is a potential material for additively manufactured intervertebral disc replacement concepts. We investigated how material properties, printing accuracy, and Gyroid architecture affect the static and cyclic compressive behavior of fused-filament-fabricated PEBA structures. Three commercial PEBA filaments were printed as twelve Gyroid geometries with cell sizes of 4–10 mm and nominal wall thicknesses of 0.50–1.00 mm. Seven material–geometry combinations were subjected to 700,000 loading cycles at 5 Hz between -600 and -2,000 N. Tensile moduli ranged from 18.82 to 38.41 MPa and yield stresses from 6.93 to 11.68 MPa, demonstrating that manufacturer-specified hardness did not predict the mechanical ranking. Several configurations reached the predefined force corridor of 4,000–8,000 N, and all cyclically tested specimens completed loading without macroscopic failure. However, load-bearing and dissipative properties evolved differently. Spectrum #08 showed pronounced decreases in loss modulus and tan δ despite increased structural stiffness. Immediately after loading, height retention ranged from 94.9% to 96.6%. After 24 h, it ranged from 95.9% to 98.2%, with significant recovery for Spectrum and Siraya Tech but not SainSmart. Paired micro-computed tomography of contrasting Spectrum #06 and #08 specimens showed preservation of the Gyroid architecture, although #08 exhibited greater localized changes in gap-closing sensitivity. Finite element analysis identified material-dependent stress magnitudes localized at curved Gyroid junctions. Overall, PEBA Gyroid mechanics were governed by material–manufacturing–architecture interactions rather than nominal hardness alone. PEBA represents a promising mechanically adaptable platform, although medical-grade materials, biological validation, and multi-specimen structural analyses are required before translation.
- Open Access
- 19 June 2026
- Published by Elsevier in SSRN Electronic Journal
The Role of Dynamic Mechanical Loading in Early Implant Osseointegration Using a Bovine Ex Vivo Bone Organ Model
Demographic changes are increasing the demand for durable orthopedic implants, necessitating reliable preclinical models to evaluate osseointegration and biomaterial performance. While in vivo models are limited by ethical constraints and species-specific differences, and conventional in vitro systems fail to reproduce the native bone microenvironment, ex vivo bone organ models represent a promising intermediate platform that preserves native tissue architecture under controlled experimental conditions. Here, an established ex vivo bovine bone organ model was optimized to investigate early bone–implant interactions under static and dynamic mechanical loading. Bovine bone cylinders were cultured for 21 days in combination with titanium implants under four conditions: continuous static loading, static loading combined with daily or weekly dynamic compression, and unloaded controls. Dynamic mechanical stimulation was applied using a displacement-controlled bioreactor system to better approximate physiological loading conditions. Explant viability and bone response were evaluated using metabolic activity assays, Live/Dead staining, histology, micro-computed tomography (µCT), and low-vacuum scanning electron microscopy (LV-SEM). Bone viability was maintained throughout the culture period, accompanied by sustained metabolic activity and extensive cell outgrowth on implant surfaces in all groups. After an initial adaptation phase, metabolic activity increased significantly over time (p < 0.01), indicating successful long-term maintenance of functional bone tissue under ex vivo conditions. Histological and µCT analyses confirmed preservation of trabecular bone architecture over 21 days, with a non-significant trend toward increased bone volume fraction under daily dynamic loading. However, no statistically significant differences were observed between mechanical loading groups across all quantitative and qualitative endpoints. Osteogenic marker analysis (ALP, osteocalcin) did not yield conclusive group-dependent differences under the applied conditions. In conclusion, a reproducible ex vivo bovine bone organ model was established that maintains viability and structural integrity over extended culture while enabling controlled mechanical stimulation and multimodal analysis of bone–implant interactions. Although the applied loading regimens did not induce pronounced osteogenic effects, the model provides a robust and physiologically relevant platform for mechanobiological studies and preclinical biomaterials evaluation. Future work should integrate perfusion-based culture strategies and refined loading parameters to further enhance physiological relevance and mechanosensitivity.
- 19 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Role of Dynamic Mechanical Loading in Early Implant Osseointegration Using a Bovine Ex Vivo Bone Organ Model
Demographic changes are increasing the demand for durable orthopedic implants, necessitating reliable preclinical models to evaluate osseointegration and biomaterial performance. While in vivo models are limited by ethical constraints and species-specific differences, and conventional in vitro systems fail to reproduce the native bone microenvironment, ex vivo bone organ models represent a promising intermediate platform that preserves native tissue architecture under controlled experimental conditions. Here, an established ex vivo bovine bone organ model was optimized to investigate early bone–implant interactions under static and dynamic mechanical loading. Bovine bone cylinders were cultured for 21 days in combination with titanium implants under four conditions: continuous static loading, static loading combined with daily or weekly dynamic compression, and unloaded controls. Dynamic mechanical stimulation was applied using a displacement-controlled bioreactor system to better approximate physiological loading conditions. Explant viability and bone response were evaluated using metabolic activity assays, Live/Dead staining, histology, micro-computed tomography (µCT), and low-vacuum scanning electron microscopy (LV-SEM). Bone viability was maintained throughout the culture period, accompanied by sustained metabolic activity and extensive cell outgrowth on implant surfaces in all groups. After an initial adaptation phase, metabolic activity increased significantly over time (p < 0.01), indicating successful long-term maintenance of functional bone tissue under ex vivo conditions. Histological and µCT analyses confirmed preservation of trabecular bone architecture over 21 days, with a non-significant trend toward increased bone volume fraction under daily dynamic loading. However, no statistically significant differences were observed between mechanical loading groups across all quantitative and qualitative endpoints. Osteogenic marker analysis (ALP, osteocalcin) did not yield conclusive group-dependent differences under the applied conditions. In conclusion, a reproducible ex vivo bovine bone organ model was established that maintains viability and structural integrity over extended culture while enabling controlled mechanical stimulation and multimodal analysis of bone–implant interactions. Although the applied loading regimens did not induce pronounced osteogenic effects, the model provides a robust and physiologically relevant platform for mechanobiological studies and preclinical biomaterials evaluation. Future work should integrate perfusion-based culture strategies and refined loading parameters to further enhance physiological relevance and mechanosensitivity.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (1) , 015001
Engineering intervertebral disc replacements using 3D-printed open Gyroid architectures
Degenerative disc disease is a leading cause of chronic back pain, and current surgical treatments such as fusion and disc arthroplasty remain limited by implant wear, stress shielding, and mechanical mismatch with the native intervertebral disc (IVD). This study investigates three-dimensional (3D) printed thermoplastic polyurethane (TPU) Gyroid structures as biomimetic disc replacements. Using filaments of varying stiffness, 3D-printed constructs demonstrated high geometric fidelity and mechanical performance within physiological load and deformation ranges. Dynamic compression testing revealed damping coefficients of approximately 16%, closely matching native IVD behavior. Stiffness scaled predictably with structural density, allowing mechanical tuning toward physiological properties. These findings highlight the potential of Gyroid-structured TPU implants to replicate the natural damping and load distribution of human discs, offering a pathway toward customizable, patient-specific disc replacements. Future work will focus on medically approved TPU, biological responses, and multiaxial loading.
- 1 December 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (1) , 015001
Open AccessEngineering intervertebral disc replacements using 3D-printed open Gyroid architectures
Degenerative disc disease is a leading cause of chronic back pain, and current surgical treatments such as fusion and disc arthroplasty remain limited by implant wear, stress shielding, and mechanical mismatch with the native intervertebral disc (IVD). This study investigates three-dimensional (3D) printed thermoplastic polyurethane (TPU) Gyroid structures as biomimetic disc replacements. Using filaments of varying stiffness, 3D-printed constructs demonstrated high geometric fidelity and mechanical performance within physiological load and deformation ranges. Dynamic compression testing revealed damping coefficients of approximately 16%, closely matching native IVD behavior. Stiffness scaled predictably with structural density, allowing mechanical tuning toward physiological properties. These findings highlight the potential of Gyroid-structured TPU implants to replicate the natural damping and load distribution of human discs, offering a pathway toward customizable, patient-specific disc replacements. Future work will focus on medically approved TPU, biological responses, and multiaxial loading.