Xun Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xun Ma has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Guangzhi Shan
Institute of Medicinal Biotechnology, Peking Union Medical College & Chinese Academy of Medical Sciences, Tian Tan Xi Li No.1, Beijing 100050, PR China
2 shared publications Xiaodan Qiu
Institute of Medicinal Biotechnology, Peking Union Medical College & Chinese Academy of Medical Sciences, Tian Tan Xi Li No.1, Beijing 100050, PR China
2 shared publicationsHuiyi Liu
Institute of Medicinal Biotechnology, Peking Union Medical College & Chinese Academy of Medical Sciences, Tian Tan Xi Li No.1, Beijing 100050, PR China
1 shared publicationKun Xiao
The Institute of Medicinal Plant Development, Peking Union Medical College & Chinese Academy of Medical Sciences, No. 151 Malianwa North Road, Beijing 100193, PR China
1 shared publication- Lianlian Shan
Xinjiang Uyghur Autonomous Region Institute for Drug Control, Urumqi 830054, China
1 shared publication - Lihui Yin
National Institutes for Food and Drug Control, Beijing 102629, China
1 shared publication
Latest Publications
- Open Access
- 27 February 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (3) , 298
Cost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy
Background/Objectives: Transmission Raman spectroscopy (TRS) is widely used for non-destructive quantification of solid dosage forms, yet most applications involve high-dose formulations (>5% w/w active pharmaceutical ingredient (API)). This study addresses the underexplored area of low-dose drug analysis by developing a TRS method for dimdazenil capsules containing only ~1.5% w/w API—a concentration rarely reported in the current TRS literature. Methods: A partial least squares (PLS) model was built using TRS spectra of dimdazenil capsules, with sample variability introduced via a design of experiments (DoE) approach. Model performance was validated against reference high-performance liquid chromatography (HPLC) data from independent samples and three commercial batches, incorporating specificity checks and greenness assessment via AGREEprep. Results: The TRS method achieved reliable variation assessment with acceptable accuracy, showing relative errors below 5.0% across all validation sets despite a minor systematic bias of ~−2.87%. Analysis required no sample preparation and took less than 150 s per capsule. Specificity was ensured by the unique 1628 cm−1 band of dimdazenil, with no interference from excipients confirmed by spectral examination and multivariate statistical methods. The method scored 0.86 on AGREEprep, highlighting its environmental superiority over HPLC. Conclusions: This work demonstrates that TRS can be reliably extended to low-dose solid dosage forms (~1.5% w/w), a concentration range rarely addressed in the existing TRS literature. This significantly broadens its applicability in pharmaceutical quality control and supports its potential integration into continuous manufacturing for challenging low-concentration products.
- 27 February 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (3) , 298
Open AccessCost-Efficient and Fast At-Line Assessment of Content and Uniformity in Low-Dose Dimdazenil Capsules Using Transmission Raman Spectroscopy
Background/Objectives: Transmission Raman spectroscopy (TRS) is widely used for non-destructive quantification of solid dosage forms, yet most applications involve high-dose formulations (>5% w/w active pharmaceutical ingredient (API)). This study addresses the underexplored area of low-dose drug analysis by developing a TRS method for dimdazenil capsules containing only ~1.5% w/w API—a concentration rarely reported in the current TRS literature. Methods: A partial least squares (PLS) model was built using TRS spectra of dimdazenil capsules, with sample variability introduced via a design of experiments (DoE) approach. Model performance was validated against reference high-performance liquid chromatography (HPLC) data from independent samples and three commercial batches, incorporating specificity checks and greenness assessment via AGREEprep. Results: The TRS method achieved reliable variation assessment with acceptable accuracy, showing relative errors below 5.0% across all validation sets despite a minor systematic bias of ~−2.87%. Analysis required no sample preparation and took less than 150 s per capsule. Specificity was ensured by the unique 1628 cm−1 band of dimdazenil, with no interference from excipients confirmed by spectral examination and multivariate statistical methods. The method scored 0.86 on AGREEprep, highlighting its environmental superiority over HPLC. Conclusions: This work demonstrates that TRS can be reliably extended to low-dose solid dosage forms (~1.5% w/w), a concentration range rarely addressed in the existing TRS literature. This significantly broadens its applicability in pharmaceutical quality control and supports its potential integration into continuous manufacturing for challenging low-concentration products.