Diego Daniel de Amorim Camilo Reif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Diego Daniel de Amorim Camilo Reif has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cristiano da Silva Teixeira
Universidade Federal de Santa Catarina
2 shared publications - Guilherme Fidelis Peixer
Research Laboratories for Emerging Technologies in Cooling and Thermophysics (POLO), Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
2 shared publications - Jader Riso Barbosa
Craft & Hawkins Department of Petroleum Engineering, Louisiana State University, Baton Rouge, United States of America
2 shared publications - Jaime A. Lozano
Research Laboratories for Emerging Technologies in Cooling and Thermophysics (POLO), Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
2 shared publications - Alan Tihiro Dias Nakashima
Department of Mechanical Engineering, Federal University of Santa Catarina 1 , Florianópolis
1 shared publication - Allan M. Döring
Technical University of Darmstadt
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
From concept to operation: Design strategies, experimental evaluation, and engineering challenges across three generations of a magnetocaloric air conditioner
Heating, refrigeration, and air conditioning systems account for 7.8% of global greenhouse gas emissions and 20% of global electricity consumption. Moreover, the demand for air conditioning is expected to triple by 2050. Magnetocaloric technology has emerged as a promising alternative, with the potential to eliminate the use of volatile fluids and reduce energy consumption. This study presents the design strategies, experimental evaluation, and key insights from the development and operation of a pilot-scale magnetocaloric air conditioner. The system was designed and optimized using Artificial Neural Networks and Genetic Algorithms, and incorporates a rotor-stator magnetic circuit, La(Fe,Mn,Si)13Hz refrigerants, and tube-fin heat exchangers. Three prototype generations were designed and commissioned, each incorporating modifications based on operational constraints. The performance evaluation highlights this prototype as achieving one of the highest cooling capacities and temperature spans reported in the literature. Also, it is the only system reported to successfully refrigerate a cold room without emulating the thermal load using heaters. The first-generation prototype delivered the best performance, achieving the required temperature spans for air conditioning (22–35 °C), although its cooling power was limited to a peak of 480 W. These results show the progress made and the obstacles that still need to be overcome to advance this technology.
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Open AccessFrom concept to operation: Design strategies, experimental evaluation, and engineering challenges across three generations of a magnetocaloric air conditioner
Heating, refrigeration, and air conditioning systems account for 7.8% of global greenhouse gas emissions and 20% of global electricity consumption. Moreover, the demand for air conditioning is expected to triple by 2050. Magnetocaloric technology has emerged as a promising alternative, with the potential to eliminate the use of volatile fluids and reduce energy consumption. This study presents the design strategies, experimental evaluation, and key insights from the development and operation of a pilot-scale magnetocaloric air conditioner. The system was designed and optimized using Artificial Neural Networks and Genetic Algorithms, and incorporates a rotor-stator magnetic circuit, La(Fe,Mn,Si)13Hz refrigerants, and tube-fin heat exchangers. Three prototype generations were designed and commissioned, each incorporating modifications based on operational constraints. The performance evaluation highlights this prototype as achieving one of the highest cooling capacities and temperature spans reported in the literature. Also, it is the only system reported to successfully refrigerate a cold room without emulating the thermal load using heaters. The first-generation prototype delivered the best performance, achieving the required temperature spans for air conditioning (22–35 °C), although its cooling power was limited to a peak of 480 W. These results show the progress made and the obstacles that still need to be overcome to advance this technology.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (12) , 1-8
Influence of the Magnetic State in the Thermo-Structural Properties of Commercially Available La(Fe,Si,Mn) 13 H z Microparticles Applied in Magnetic Refrigeration Prototypes
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (12) , 1-8
Influence of the Magnetic State in the Thermo-Structural Properties of Commercially Available La(Fe,Si,Mn) 13 H z Microparticles Applied in Magnetic Refrigeration Prototypes