Musa Marul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Musa Marul has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Nurhan Gürsel Özmen
Karadeniz Teknik Üniversitesi
3 shared publications - Arzu Erden
Karadeniz Teknik Üniversitesi
1 shared publication - Erman Aydin
AYDIN ADNAN MENDERES ÜNİVERSİTESİ, SÖKE MESLEK YÜKSEKOKULU, MOTORLU ARAÇLAR VE ULAŞTIRMA TEKNOLOJİLERİ BÖLÜMÜ
1 shared publication - Nurullah Yelboğa
Şırnak University
1 shared publication
Latest Publications
- 17 March 2026
- Published by T.C. Sağlık Bakanlığı in Sağlıkta Performans ve Kalite Dergisi
- No. 23
CONCEPTUAL PATIENT-CENTERED INTERDISCIPLINARY FRAMEWORK FOR ROBOT-ASSISTED HAND AND WRIST REHABILITATION
This study develops a patient-centered interdisciplinary framework for robot-assisted hand and wrist rehabilitation that integrates robotic engineering, physiotherapy, hospital-based social work, and health-service quality assessment. A Design Science Research (DSR)-guided conceptual development approach was combined with a structured narrative synthesis of technical, clinical, psychosocial, and health-service literature. Evidence underwent four-dimensional analytical mapping across engineering and robotic control, physiotherapy and functional rehabilitation, social work and psychosocial adaptation, and health-service quality and performance to identify framework components and interdisciplinary decision links. This mapping organized literature-based evidence rather than constituting a validated measurement instrument or clinical assessment. The resulting framework was subsequently appraised conceptually, without scoring, against six criteria: structural integrity, clinical applicability, patient safety, psychosocial integration, quality and process performance, and implementation sustainability. It proposes a care pathway connecting patient assessment, parallel interdisciplinary planning, robot-assisted rehabilitation, clinical observation, and coordinated review. Candidate indicators include patient satisfaction, treatment adherence, functional improvement, safety events, process performance, continuity of care, psychosocial adaptation, and resource use. These indicators are intended to inform future clinical and service-level decisions; they were not tested as decision rules or demonstrated to improve patient outcomes. No patient-level data were collected, and no expert-consensus validation, clinical pilot, or effectiveness testing was conducted. The study contributes a literature-derived architecture with explicit information and decision pathways and a basis for future empirical evaluation. Implementation feasibility, safety performance, and clinical effectiveness remain unverified.
- 17 March 2026
- Published by T.C. Sağlık Bakanlığı in Sağlıkta Performans ve Kalite Dergisi
- No. 23
CONCEPTUAL PATIENT-CENTERED INTERDISCIPLINARY FRAMEWORK FOR ROBOT-ASSISTED HAND AND WRIST REHABILITATION
This study develops a patient-centered interdisciplinary framework for robot-assisted hand and wrist rehabilitation that integrates robotic engineering, physiotherapy, hospital-based social work, and health-service quality assessment. A Design Science Research (DSR)-guided conceptual development approach was combined with a structured narrative synthesis of technical, clinical, psychosocial, and health-service literature. Evidence underwent four-dimensional analytical mapping across engineering and robotic control, physiotherapy and functional rehabilitation, social work and psychosocial adaptation, and health-service quality and performance to identify framework components and interdisciplinary decision links. This mapping organized literature-based evidence rather than constituting a validated measurement instrument or clinical assessment. The resulting framework was subsequently appraised conceptually, without scoring, against six criteria: structural integrity, clinical applicability, patient safety, psychosocial integration, quality and process performance, and implementation sustainability. It proposes a care pathway connecting patient assessment, parallel interdisciplinary planning, robot-assisted rehabilitation, clinical observation, and coordinated review. Candidate indicators include patient satisfaction, treatment adherence, functional improvement, safety events, process performance, continuity of care, psychosocial adaptation, and resource use. These indicators are intended to inform future clinical and service-level decisions; they were not tested as decision rules or demonstrated to improve patient outcomes. No patient-level data were collected, and no expert-consensus validation, clinical pilot, or effectiveness testing was conducted. The study contributes a literature-derived architecture with explicit information and decision pathways and a basis for future empirical evaluation. Implementation feasibility, safety performance, and clinical effectiveness remain unverified.
- Open Access
- 3 December 2025
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 112 (1)
Design and Production of a Novel Cable Supported Hand and Wrist Rehabilitation Robot: Prototype Study
- 3 December 2025
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 112 (1)
Open AccessDesign and Production of a Novel Cable Supported Hand and Wrist Rehabilitation Robot: Prototype Study
- 1 December 2025
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 13 (4) , 1107-1136
METAHEURISTIC METHODS OPTIMIZED HSMC CONTROL OF A MULTI DOF HAND AND WRIST REHABILITATION ROBOT DESIGN
Rehabilitation is a process that aims to restore individuals to full functionality following an injury or illness that has compromised their ability to perform daily activities. A significant challenge in addressing these needs is the selection of robotic devices that can adequately respond to the complex requirements of rehabilitation. This study presents a simulation study for the position control of the wrist and fingers using Hierarchical Sliding Mode Control (HSMC) that is optimized via metaheuristic algorithms. A novel hierarchical approach is applied that is optimized with Particle Swarm Optimization (PSO) and Differential Evolution (DE) algorithms. The model was simulated under disturbances to track the desired trajectory. Simulation results are compared with Hierarchical PID controller results. The findings demonstrate that HSMC-based control effectively improve trajectory tracking, reducing mean absolute and normalized root mean square (NRMS) errors compared to HPID controllers. The proposed approach shows promising potential for real implementation, enhancing the efficiency of rehabilitation devices.
- 1 December 2025
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 13 (4) , 1107-1136
METAHEURISTIC METHODS OPTIMIZED HSMC CONTROL OF A MULTI DOF HAND AND WRIST REHABILITATION ROBOT DESIGN
Rehabilitation is a process that aims to restore individuals to full functionality following an injury or illness that has compromised their ability to perform daily activities. A significant challenge in addressing these needs is the selection of robotic devices that can adequately respond to the complex requirements of rehabilitation. This study presents a simulation study for the position control of the wrist and fingers using Hierarchical Sliding Mode Control (HSMC) that is optimized via metaheuristic algorithms. A novel hierarchical approach is applied that is optimized with Particle Swarm Optimization (PSO) and Differential Evolution (DE) algorithms. The model was simulated under disturbances to track the desired trajectory. Simulation results are compared with Hierarchical PID controller results. The findings demonstrate that HSMC-based control effectively improve trajectory tracking, reducing mean absolute and normalized root mean square (NRMS) errors compared to HPID controllers. The proposed approach shows promising potential for real implementation, enhancing the efficiency of rehabilitation devices.