P. D. Yepiz-Graciano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
P. D. Yepiz-Graciano has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
D. Salamanca-Roldán
Centro de Investigaciones en Óptica A.C., Loma del Bosque 115, Colonia Lomas del Campestre, León, México
2 shared publicationsH. Cruz-Ramírez
Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, CdMx, Mexico
2 shared publications- Roberto Ramírez-Alarcón
Centro de Investigaciones en Óptica A.C., Loma del Bosque 115, Colonia Lomas del Campestre, León, México
2 shared publications A. B. U'Ren
1 shared publicationA. B. U’REn
Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, CdMx, Mexico
1 shared publication- Gabriel Ramos-Ortiz
Centro de Investigaciones en Óptica, A. C.https://ror.org/00q8h8k29, A. P. 1-948, 37000 León, Gto., Mexico
1 shared publication
Latest Publications
- Open Access
- 7 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Sub-second a-scan acquisition using marginal spectral-domain quantum optical coherence tomography
We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples in the absence of mechanical scanning, at an unprecedented speed. Implementing a novel strategy, we demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera and a high-flux photon-pair source operating in the VIS–NIR region (\(\approx\)800 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms for a mirror sample, which extends to 10 s for a glass coverslip, and a penetration depth of \(\approx\)4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications.- 7 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSub-second a-scan acquisition using marginal spectral-domain quantum optical coherence tomography
We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples in the absence of mechanical scanning, at an unprecedented speed. Implementing a novel strategy, we demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera and a high-flux photon-pair source operating in the VIS–NIR region (\(\approx\)800 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms for a mirror sample, which extends to 10 s for a glass coverslip, and a penetration depth of \(\approx\)4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications. - Open Access
Optimized spectral and interferometric techniques for the certification of ETPA
The phenomenon of Entangled Two-Photon Absorption (ETPA) presents a persistent controversy in the literature, evidenced by a wide disparity in the reported values for the $σ_E$ cross-sections. Much of this discrepancy is attributed to the difficulty in discriminating ETPA from various background processes that can mimic its signal, such as linear absorption or scattering. Given this need to certify the presence of ETPA unequivocally, this work introduces a key strategy to isolate the ETPA contribution through its spectral signature. This involves modeling the molecule as a two-photon notch filter and inducing a controlled asymmetric overlap with the joint spectral intensity (JSI) of the incident photons. This asymmetry is used to generate a measurable distortion in the transmitted JSI, and, complementarily, as a reduction in the visibility of the Hong-Ou-Mandel (HOM) dip. To ensure the experimental feasibility of this technique, a comprehensive analysis of the experimental conditions required for its detection is presented, establishing the absorption efficiency limits that must be overcome given the constraints of entangled-photon-pair flux and detector noise. A preliminary experiment addressing the ETPA detection limits using the standard RhB dye is presented.Open AccessOptimized spectral and interferometric techniques for the certification of ETPA
The phenomenon of Entangled Two-Photon Absorption (ETPA) presents a persistent controversy in the literature, evidenced by a wide disparity in the reported values for the $σ_E$ cross-sections. Much of this discrepancy is attributed to the difficulty in discriminating ETPA from various background processes that can mimic its signal, such as linear absorption or scattering. Given this need to certify the presence of ETPA unequivocally, this work introduces a key strategy to isolate the ETPA contribution through its spectral signature. This involves modeling the molecule as a two-photon notch filter and inducing a controlled asymmetric overlap with the joint spectral intensity (JSI) of the incident photons. This asymmetry is used to generate a measurable distortion in the transmitted JSI, and, complementarily, as a reduction in the visibility of the Hong-Ou-Mandel (HOM) dip. To ensure the experimental feasibility of this technique, a comprehensive analysis of the experimental conditions required for its detection is presented, establishing the absorption efficiency limits that must be overcome given the constraints of entangled-photon-pair flux and detector noise. A preliminary experiment addressing the ETPA detection limits using the standard RhB dye is presented. - Open Access
Sub-second A-scan Acquisition Using Marginal Spectral-Domain Quantum Optical Coherence Tomography
We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples without in the absence of mechanical scanning, at an unprecedented speed. We demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera, and a high-flux photon-pair source operating in the VIS-NIR region (810 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms and a penetration depth of 4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications.
Open AccessSub-second A-scan Acquisition Using Marginal Spectral-Domain Quantum Optical Coherence Tomography
We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples without in the absence of mechanical scanning, at an unprecedented speed. We demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera, and a high-flux photon-pair source operating in the VIS-NIR region (810 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms and a penetration depth of 4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications.