Khaled Ahmed Fawaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Khaled Ahmed Fawaz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Amr Ahmed Azhari
Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
2 shared publications - Walaa Magdy Ahmed
Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
2 shared publications - A. Sameh
Mechanical Engineering Department, Mechanical Engineering Department, Arab Academy for Science Technology and Maritime Transport, Sheraton Branch, Cairo, Egypt, Egypt
1 shared publication Abdulrahman Almufti
Master Prosthodontic Program, Faculty of Dentistry Riyadh Elm University Riyadh Saudi Arabia
1 shared publication- Ahmed Abdellatif Hamed Ibrahim
Mechanical Engineering Department, Arab Academy for Science Technology and Maritime Transport, Sheraton Branch, Cairo 11757, Egypt
1 shared publication Amr Fawzy Abdelhamid Ahmed
Department Artificial Intelligence Tachyhealth Company Lewes Delaware USA
1 shared publication
Latest Publications
- Open Access
- 14 May 2026
- Published by MDPI AG in Preprints.org
A Systematic Review of Supernumerary Robotic Limbs: Design Trade-Offs, Control Strategies, and Application Domains
Supernumerary robotic limbs (SRLs) represent an emerging class of wearable robotic systems designed to augment, rather than replace, human motor capabilities. Unlike prostheses or exoskeletons, SRLs operate as independent kinematic agents that enable users to perform multi-limb tasks, reduce physical workload, and enhance operational efficiency in complex environments. This study presents a systematic review of SRL technologies, focusing on mechanical design configurations, sensing modalities, and control strategies, and their influence on key performance metrics such as payload capacity, positioning accuracy, and human–robot interaction efficiency. A structured literature review methodology was adopted following PRISMA guidelines, covering publications from 2010 to 2025 across major scientific databases. The analysis reveals fundamental trade-offs between degrees of freedom, weight, and payload capacity, where high-dexterity systems often impose increased ergonomic burden. Control strategies have evolved from direct teleoperation toward hybrid and shared-autonomy frameworks integrating vision, bio-signals, and machine learning, although challenges remain in achieving intuitive and low-latency interaction. Application domains span industrial manufacturing, construction, rehabilitation, and assistive daily activities, with growing interest in precision-constrained environments such as healthcare. Despite significant progress, limitations persist in actuator back-drivability, long-term wearability, and robust intention recognition under real-world conditions. This review synthesizes current advancements, identifies critical research gaps, and outlines future directions toward scalable, human-centric SRL systems capable of seamless integration into industrial and clinical workflows.
- 14 May 2026
- Published by MDPI AG in Preprints.org
Open AccessA Systematic Review of Supernumerary Robotic Limbs: Design Trade-Offs, Control Strategies, and Application Domains
Supernumerary robotic limbs (SRLs) represent an emerging class of wearable robotic systems designed to augment, rather than replace, human motor capabilities. Unlike prostheses or exoskeletons, SRLs operate as independent kinematic agents that enable users to perform multi-limb tasks, reduce physical workload, and enhance operational efficiency in complex environments. This study presents a systematic review of SRL technologies, focusing on mechanical design configurations, sensing modalities, and control strategies, and their influence on key performance metrics such as payload capacity, positioning accuracy, and human–robot interaction efficiency. A structured literature review methodology was adopted following PRISMA guidelines, covering publications from 2010 to 2025 across major scientific databases. The analysis reveals fundamental trade-offs between degrees of freedom, weight, and payload capacity, where high-dexterity systems often impose increased ergonomic burden. Control strategies have evolved from direct teleoperation toward hybrid and shared-autonomy frameworks integrating vision, bio-signals, and machine learning, although challenges remain in achieving intuitive and low-latency interaction. Application domains span industrial manufacturing, construction, rehabilitation, and assistive daily activities, with growing interest in precision-constrained environments such as healthcare. Despite significant progress, limitations persist in actuator back-drivability, long-term wearability, and robust intention recognition under real-world conditions. This review synthesizes current advancements, identifies critical research gaps, and outlines future directions toward scalable, human-centric SRL systems capable of seamless integration into industrial and clinical workflows.
- Open Access
- 26 November 2025
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (1) , 81-93
Development and evaluation of an AI model for dental implant type detection: A comparison of diagnostic accuracy between a deep learning model and dental professionals
Purpose: To develop a deep‐learning system for identifying five dental implant brands from periapical radiographs and compare its diagnostic accuracy with dental professionals and evaluate successive You Only Look Once (YOLO) architectures (v7–v12) to justify model selection. Materials and Methods: A dataset of 5851 periapical radiographs was compiled and divided into training, validation, and test partitions (80/10/10). After filtering to five brands (Adin, Dentium, Noris, OSSTEM, and Straumann), YOLO‐based object detection models (versions 7–12) were trained and tested under identical conditions. The YOLOv12x model was adopted for final evaluation based on its optimal balance of accuracy and inference speed. Human performance was assessed using 100 held‐out test images (20 per brand) via a multiple‐choice web survey distributed to six clinician groups. Diagnostic metrics included mean average precision at IoU 0.50 (mAP@50), mAP@50–95, precision, recall, and accuracy. Results: The model achieved an mAP@50 of 0.989 (98.9%), an mAP@50–95 of 0.900 (90.0%), a precision of 0.969 (96.9%), and a recall of 0.977 (97.7%) across brands. Across YOLO generations, performance improved from mAP@50–95 = 0.817 (YOLOv7) to 0.905 (YOLOv12x). Fifty‐two clinicians completed 5,200 image evaluations; the model significantly outperformed all clinician subgroups (one‐way ANOVA with Tukey HSD, p < 0.001). Transformer‐based DF‐DETR achieved mAP@50–95 = 0.878, confirming YOLOv12x's superior efficiency–accuracy trade‐off. Conclusions: A high‐performing model identified implant brands on periapical radiographs and outperformed clinicians across experience levels. Comparative analysis across YOLO architectures validated its measurable advantage in accuracy and speed. Lack of external validation and dataset imbalance are important limitations; future work will include external, multisite data and human–AI workflow evaluation.
- 26 November 2025
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (1) , 81-93
Open AccessDevelopment and evaluation of an AI model for dental implant type detection: A comparison of diagnostic accuracy between a deep learning model and dental professionals
Purpose: To develop a deep‐learning system for identifying five dental implant brands from periapical radiographs and compare its diagnostic accuracy with dental professionals and evaluate successive You Only Look Once (YOLO) architectures (v7–v12) to justify model selection. Materials and Methods: A dataset of 5851 periapical radiographs was compiled and divided into training, validation, and test partitions (80/10/10). After filtering to five brands (Adin, Dentium, Noris, OSSTEM, and Straumann), YOLO‐based object detection models (versions 7–12) were trained and tested under identical conditions. The YOLOv12x model was adopted for final evaluation based on its optimal balance of accuracy and inference speed. Human performance was assessed using 100 held‐out test images (20 per brand) via a multiple‐choice web survey distributed to six clinician groups. Diagnostic metrics included mean average precision at IoU 0.50 (mAP@50), mAP@50–95, precision, recall, and accuracy. Results: The model achieved an mAP@50 of 0.989 (98.9%), an mAP@50–95 of 0.900 (90.0%), a precision of 0.969 (96.9%), and a recall of 0.977 (97.7%) across brands. Across YOLO generations, performance improved from mAP@50–95 = 0.817 (YOLOv7) to 0.905 (YOLOv12x). Fifty‐two clinicians completed 5,200 image evaluations; the model significantly outperformed all clinician subgroups (one‐way ANOVA with Tukey HSD, p < 0.001). Transformer‐based DF‐DETR achieved mAP@50–95 = 0.878, confirming YOLOv12x's superior efficiency–accuracy trade‐off. Conclusions: A high‐performing model identified implant brands on periapical radiographs and outperformed clinicians across experience levels. Comparative analysis across YOLO architectures validated its measurable advantage in accuracy and speed. Lack of external validation and dataset imbalance are important limitations; future work will include external, multisite data and human–AI workflow evaluation.