Meenu Malik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meenu Malik has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Babita Khosla
Department of Environmental Sciences, Maharshi Dayanand University, Rohtak, India
2 shared publications - Jitender Singh Laura
Department of Environmental Sciences, Maharshi Dayanand University, Rohtak, India
2 shared publications - Pinkey Sheoran
Department of Electrical Engineering, UIET, Maharshi Dayanand University, Rohtak, India
1 shared publication
Latest Publications
- 1 August 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (12) , 500
Assessment of groundwater radioactivity and radiological health risk around a coal-based thermal power plant
- 1 August 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (12) , 500
Assessment of groundwater radioactivity and radiological health risk around a coal-based thermal power plant
- 4 December 2025
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (1) , 26
Fly ash fallout gamma radiation distribution around a coal based thermal power plant and its radiological health risk
The study assessed outdoor gamma radiation levels associated with fly ash dispersion from a 2820 MW coal-fired super thermal power plant located in Jhajjar district, Haryana, India. Gamma dose rates (GDR) were measured at 46 locations within a 20 km radius of the plant and at six reference locations beyond 20 km, during summer and winter seasons. The spatial distribution of radiation was heterogeneous, with two distinct hotspots identified along the east–west axis, attributable to increased fly ash deposition driven by prevailing local wind conditions. Measured GDR ranged from 92 to 206 nSv/h, with a mean value of 140.86 ± 32 nSv/h, which is notably higher than the regional background mean of 93.8 ± 20 nSv/h recorded beyond 20 km. The estimated annual effective dose (AED) varied between 0.112 and 0.257 mSv/y with a mean value of 0.171 mSv/y, remaining below the internationally recommended public dose limit. Excess lifetime cancer risk (ELCR) within the hotspot zones ranged from 4.20 × 10−4 to 9.64 × 10−4 with a mean value of 6.45 × 10−4, compared with a mean of 4.16 × 10−4 at locations beyond 20 km. These values correspond to approximately 645 and 412 excess cancer cases per million individuals, respectively. The findings highlighted the potential long-term radiological health risks in the vicinity of coal-based thermal power plants. Furthermore, the study established radiological baseline data that would be essential for ongoing and future environmental monitoring programs.
- 4 December 2025
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (1) , 26
Fly ash fallout gamma radiation distribution around a coal based thermal power plant and its radiological health risk
The study assessed outdoor gamma radiation levels associated with fly ash dispersion from a 2820 MW coal-fired super thermal power plant located in Jhajjar district, Haryana, India. Gamma dose rates (GDR) were measured at 46 locations within a 20 km radius of the plant and at six reference locations beyond 20 km, during summer and winter seasons. The spatial distribution of radiation was heterogeneous, with two distinct hotspots identified along the east–west axis, attributable to increased fly ash deposition driven by prevailing local wind conditions. Measured GDR ranged from 92 to 206 nSv/h, with a mean value of 140.86 ± 32 nSv/h, which is notably higher than the regional background mean of 93.8 ± 20 nSv/h recorded beyond 20 km. The estimated annual effective dose (AED) varied between 0.112 and 0.257 mSv/y with a mean value of 0.171 mSv/y, remaining below the internationally recommended public dose limit. Excess lifetime cancer risk (ELCR) within the hotspot zones ranged from 4.20 × 10−4 to 9.64 × 10−4 with a mean value of 6.45 × 10−4, compared with a mean of 4.16 × 10−4 at locations beyond 20 km. These values correspond to approximately 645 and 412 excess cancer cases per million individuals, respectively. The findings highlighted the potential long-term radiological health risks in the vicinity of coal-based thermal power plants. Furthermore, the study established radiological baseline data that would be essential for ongoing and future environmental monitoring programs.