Tugba Cavis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tugba Cavis has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Edibe Gözde Başaran
Division of Pediatric Gastroenterology, Department of Child Health and Diseases, Gülhane Training and Research Hospital, Ankara, Türkiye
3 shared publications - Necati Balamtekin
Division of Pediatric Gastroenterology, Department of Child Health and Diseases, Gülhane Training and Research Hospital, Ankara, Türkiye
3 shared publications - Selçuk Teke
Department of Pediatrics/Division of Pediatric Gastroenterology Gülhane Training and Research Hospital Ankara Turkey
3 shared publications - Yasin Maruf Ergen
Department of Pediatrics/Division of Pediatric Gastroenterology Gülhane Training and Research Hospital Ankara Turkey
3 shared publications - Birce İzGi Akçay
Department of Pediatrics/Division of Pediatric Gastroenterology, Gülhane Training and Research Hospital, Ankara, Turkey
2 shared publications Abdurahman Urve Uzun
1 shared publication
Latest Publications
- 5 August 2026
- Published by Wolters Kluwer Health in American Journal of Therapeutics
Carbamazepine-Associated Granulomatous Hepatitis in a Pediatric Patient: A Case Report
Was not provided for this article.
- 5 August 2026
- Published by Wolters Kluwer Health in American Journal of Therapeutics
Carbamazepine-Associated Granulomatous Hepatitis in a Pediatric Patient: A Case Report
Was not provided for this article.
- Open Access
- 24 March 2026
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 37 (6) , 657-664
Thrombotic Risk and Hemostatic Profiles in Pediatric Inflammatory Bowel Disease: Association with Disease Activity
Background/Aims: Inflammatory bowel disease (IBD) increases thromboembolic risk, but pediatric evidence remains limited. The current study evaluated the associations between coagulation markers, systemic inflammation, and disease activity in pediatric IBD and assessed the prevalence of silent thrombosis. Materials and Methods: A total of 46 pediatric patients with IBD were enrolled in this single-center cross-sectional study. All underwent Doppler ultrasonography of the lower extremities and the portal venous system. Hemostatic and inflammatory markers were evaluated in the laboratory and were analyzed in relation to disease activity. Results: One asymptomatic thrombus was detected in a patient with Crohn’s disease (CD). Factor VIII was significantly higher in ulcerative colitis (UC) compared to CD (median 109.5 vs. 74.3 IU/dL, P = .007). In UC, platelet count and D-dimer increased with increasing disease activity and extent. There was a significant relationship between platelet counts and the endoscopic extent (P = .008) and Mayo Score (P = .031). In CD, fibrinogen and factor VIII levels revealed a positive correlation with Pediatric Crohn’s Disease Activity Index scores (P = .012 and P = .040, respectively) but not with the Simple Endoscopic Score. Corticosteroid use was linked to higher factor VII (P = .017). Conclusion: Asymptomatic thrombosis rare in IBD, but inflammation and procoagulant activity were closely related, especially in UC. Platelet count, D-dimer, and factor VIII might serve as biomarkers for thrombotic risk and monitoring. Cite this article as: Ergen YM, Başaran EG, Teke S, .aviş T, Balamtekin N. Thrombotic risk and hemostatic profiles in pediatric inflammatory bowel disease: Association with disease activity. Turk J Gastroenterol. Published online March 24, 2026. doi: 10.5152/ tjg.2026.25541.
- 24 March 2026
- Published by AVES YAYINCILIK A.Ş. in Turkish Journal of Gastroenterology
- Vol. 37 (6) , 657-664
Open AccessThrombotic Risk and Hemostatic Profiles in Pediatric Inflammatory Bowel Disease: Association with Disease Activity
Background/Aims: Inflammatory bowel disease (IBD) increases thromboembolic risk, but pediatric evidence remains limited. The current study evaluated the associations between coagulation markers, systemic inflammation, and disease activity in pediatric IBD and assessed the prevalence of silent thrombosis. Materials and Methods: A total of 46 pediatric patients with IBD were enrolled in this single-center cross-sectional study. All underwent Doppler ultrasonography of the lower extremities and the portal venous system. Hemostatic and inflammatory markers were evaluated in the laboratory and were analyzed in relation to disease activity. Results: One asymptomatic thrombus was detected in a patient with Crohn’s disease (CD). Factor VIII was significantly higher in ulcerative colitis (UC) compared to CD (median 109.5 vs. 74.3 IU/dL, P = .007). In UC, platelet count and D-dimer increased with increasing disease activity and extent. There was a significant relationship between platelet counts and the endoscopic extent (P = .008) and Mayo Score (P = .031). In CD, fibrinogen and factor VIII levels revealed a positive correlation with Pediatric Crohn’s Disease Activity Index scores (P = .012 and P = .040, respectively) but not with the Simple Endoscopic Score. Corticosteroid use was linked to higher factor VII (P = .017). Conclusion: Asymptomatic thrombosis rare in IBD, but inflammation and procoagulant activity were closely related, especially in UC. Platelet count, D-dimer, and factor VIII might serve as biomarkers for thrombotic risk and monitoring. Cite this article as: Ergen YM, Başaran EG, Teke S, .aviş T, Balamtekin N. Thrombotic risk and hemostatic profiles in pediatric inflammatory bowel disease: Association with disease activity. Turk J Gastroenterol. Published online March 24, 2026. doi: 10.5152/ tjg.2026.25541.
- 16 March 2026
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 82 (6) , 1458-1465
Diagnostic utility of shear wave elastography in pediatric celiac disease: Assessment of mesenteric and ileal stiffness
Objective: To investigate the diagnostic utility of abdominal shear wave elastography (SWE) in pediatric celiac disease (CD) by assessing mesenteric and terminal ileal stiffness and its association with serologic activity, histologic severity, and gluten‐free diet (GFD) duration. Methods: In this prospective study, 84 children with CD and 80 matched healthy controls were evaluated. Mesenteric and terminal ileal stiffness values were measured using SWE. CD patients were stratified by GFD duration (short‐term: ≤6 months vs. long‐term: >6 months) and tissue transglutaminase immunoglobulin A (tTG‐IgA) levels. Diagnostic performance was determined using receiver operating characteristic (ROC) curves. Results: Mesenteric and ileal SWE values were significantly higher in CD patients than controls ( p < 0.001 for both). Mesenteric stiffness demonstrated an area under the ROC curve (AUC) of 0.81 with an optimal cut‐off of 9.03 kPa, while ileal stiffness showed an AUC of 0.83 with a cut‐off of 9.71 kPa. Subgroup analysis revealed no significant difference in baseline Marsh scores between the short‐term and long‐term GFD groups ( p = 0.305), despite a dramatic decline in tTG‐IgA levels in the long‐term group ( p < 0.001). Elevated stiffness persisted in both newly diagnosed and GFD‐treated patients compared with controls (all p < 0.001). No significant correlations were observed between SWE values and concurrent tTG‐IgA levels or Marsh subtypes (all p > 0.05). Conclusion: Increased mesenteric and ileal stiffness in children with CD likely reflect transmural involvement and structural remodeling beyond the mucosal injury. These findings demonstrate that SWE has good diagnostic utility and may serve as a valuable complementary noninvasive tool in the evaluation and clinical monitoring of pediatric CD.
- 16 March 2026
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 82 (6) , 1458-1465
Diagnostic utility of shear wave elastography in pediatric celiac disease: Assessment of mesenteric and ileal stiffness
Objective: To investigate the diagnostic utility of abdominal shear wave elastography (SWE) in pediatric celiac disease (CD) by assessing mesenteric and terminal ileal stiffness and its association with serologic activity, histologic severity, and gluten‐free diet (GFD) duration. Methods: In this prospective study, 84 children with CD and 80 matched healthy controls were evaluated. Mesenteric and terminal ileal stiffness values were measured using SWE. CD patients were stratified by GFD duration (short‐term: ≤6 months vs. long‐term: >6 months) and tissue transglutaminase immunoglobulin A (tTG‐IgA) levels. Diagnostic performance was determined using receiver operating characteristic (ROC) curves. Results: Mesenteric and ileal SWE values were significantly higher in CD patients than controls ( p < 0.001 for both). Mesenteric stiffness demonstrated an area under the ROC curve (AUC) of 0.81 with an optimal cut‐off of 9.03 kPa, while ileal stiffness showed an AUC of 0.83 with a cut‐off of 9.71 kPa. Subgroup analysis revealed no significant difference in baseline Marsh scores between the short‐term and long‐term GFD groups ( p = 0.305), despite a dramatic decline in tTG‐IgA levels in the long‐term group ( p < 0.001). Elevated stiffness persisted in both newly diagnosed and GFD‐treated patients compared with controls (all p < 0.001). No significant correlations were observed between SWE values and concurrent tTG‐IgA levels or Marsh subtypes (all p > 0.05). Conclusion: Increased mesenteric and ileal stiffness in children with CD likely reflect transmural involvement and structural remodeling beyond the mucosal injury. These findings demonstrate that SWE has good diagnostic utility and may serve as a valuable complementary noninvasive tool in the evaluation and clinical monitoring of pediatric CD.
- 4 December 2025
- Published by Springer Nature in Bratislava Medical Journal
- Vol. 127 (1) , 219-229
Comparative Assessment of CT and MRI in Orbital Measurement: Accuracy, Agreement, and Reliability
- 4 December 2025
- Published by Springer Nature in Bratislava Medical Journal
- Vol. 127 (1) , 219-229
Comparative Assessment of CT and MRI in Orbital Measurement: Accuracy, Agreement, and Reliability
- 2 December 2025
- Published by Taylor & Francis in The Physician and Sportsmedicine
- Vol. 54 (2) , 124-131
Measurement of specific shoulder joint distances with handheld and conventional ultrasound: a reliability and agreement study
Ultrasonography is a widely accepted imaging method for evaluating anatomical structures around the shoulder joint. However, the consistency of measurements across different devices and operators remains a critical issue for clinical and research validity. The aim of this study is to assess the inter-device and intra-operator reliability of ultrasound-based measurements of four key anatomical shoulder distances and to establish normative reference values in a healthy population. A total of 195 healthy volunteers (390 shoulders) underwent ultrasonographic evaluation of the acromioclavicular distance (AC), coracoclavicular distance (CC), acromiohumeral distance (AH), and coracohumeral distance (CH). Two physicians, TC (radiologist) and GB (sports medicine), performed the measurements independently using two different ultrasound machines: Siemens S3000 and C10X, respectively. To assess intra-rater temporal reliability, all measurements were repeated on the same participants after two weeks. Stratified sex-matched randomization was applied during participant recruitment. AC, AH, and CH ultrasound measurements showed intra- and inter-rater reliability with minimal bias and acceptable limits of agreement, indicating good consistency and interchangeability. In contrast, CC measurements exhibited significant inter-rater differences (p = 0.034 and p = 0.023) and wide limits of agreement, reflecting greater variability and limited interchangeability. Given their consistent performance across statistical methods, AC, AH, and CH measurements may be used interchangeably across different raters or sessions, particularly in clinical or research settings where reliable reproducibility is essential. However, due to its high inter-rater variability and broad limits of agreement, CC measurements are not recommended for interchangeable use between evaluators or devices.
- 2 December 2025
- Published by Taylor & Francis in The Physician and Sportsmedicine
- Vol. 54 (2) , 124-131
Measurement of specific shoulder joint distances with handheld and conventional ultrasound: a reliability and agreement study
Ultrasonography is a widely accepted imaging method for evaluating anatomical structures around the shoulder joint. However, the consistency of measurements across different devices and operators remains a critical issue for clinical and research validity. The aim of this study is to assess the inter-device and intra-operator reliability of ultrasound-based measurements of four key anatomical shoulder distances and to establish normative reference values in a healthy population. A total of 195 healthy volunteers (390 shoulders) underwent ultrasonographic evaluation of the acromioclavicular distance (AC), coracoclavicular distance (CC), acromiohumeral distance (AH), and coracohumeral distance (CH). Two physicians, TC (radiologist) and GB (sports medicine), performed the measurements independently using two different ultrasound machines: Siemens S3000 and C10X, respectively. To assess intra-rater temporal reliability, all measurements were repeated on the same participants after two weeks. Stratified sex-matched randomization was applied during participant recruitment. AC, AH, and CH ultrasound measurements showed intra- and inter-rater reliability with minimal bias and acceptable limits of agreement, indicating good consistency and interchangeability. In contrast, CC measurements exhibited significant inter-rater differences (p = 0.034 and p = 0.023) and wide limits of agreement, reflecting greater variability and limited interchangeability. Given their consistent performance across statistical methods, AC, AH, and CH measurements may be used interchangeably across different raters or sessions, particularly in clinical or research settings where reliable reproducibility is essential. However, due to its high inter-rater variability and broad limits of agreement, CC measurements are not recommended for interchangeable use between evaluators or devices.