AAArnur Askhatov

Arnur Askhatov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arnur Askhatov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Study of Ultrasonic Nanocrystalline Surface Modification, Ion-Plasma Nitriding, and Their Combined Treatment on the Tribological Properties of AISI 321 Stainless Steel

    by Meruyert Adilkanova, Zarina Aringozhina, Arnur Askhatov, Nurtoleu Magazov, Bauyrzhan Rakhadilov, Saule Abdulina

    This study presents a comparative investigation of the effects of ultrasonic nanocrystalline surface modification (UNSM), ion-plasma nitriding (IPN), and their sequential combination on the mechanical and tribological properties of 12X18H10T austenitic stainless steel. To evaluate the effectiveness of the treatments, the phase composition, hardness, elastic modulus, wear track morphology, coefficient of friction, and wear rate were investigated. It was found that IPN provides the most significant increase in surface hardness, from 260 to 1239 HV, and a reduction in wear rate to approximately 2 × 10−5 mm3/(N·m). At the same time, the average width of the wear track decreases to ≈405 μm compared to ≈972 μm for the initial specimen. After UNSM, the hardness increases to 511 HV, the coefficient of friction decreases to ≈0.62, and the wear rate is ≈2.8 × 10−4 mm3/(N·m). The combined UNSM+IPN treatment yields a minimum coefficient of friction of ≈0.55 and a maximum elastic modulus of 251.5 GPa, with hardness reaching 689 HV. SEM and X-ray phase analysis results showed that differences in tribological behavior are associated with the characteristics of structural hardening, phase formation, and the resistance of the modified surface layer to plastic deformation and local failure. Importantly, the comparative analysis revealed that the coefficient of friction, surface hardness, and wear rate do not exhibit a direct proportional relationship. In particular, IPN produced the highest hardness and the lowest wear rate despite a relatively high coefficient of friction, whereas the combined UNSM+IPN treatment resulted in the lowest coefficient of friction but did not provide the minimum wear rate. This decoupling demonstrates that friction and wear behavior are governed by different aspects of the structural and mechanical state of the modified surface. Therefore, the effectiveness of surface treatments should be evaluated using a combination of mechanical, structural, and tribological characteristics rather than a single parameter.

  • Open Access

    Non-Monotonic Effect of Duty Cycle on the Mechanical, Tribological, and Corrosion Properties of Pulsed DC Plasma-Nitrided 12Cr18Ni10Ti Stainless Steel

    by Nurtoleu Magazov, Arnur Askhatov, Kuanysh Ormanbekov, Bauyrzhan Rakhadilov, Meruyert Adilkanova, Zarina Aringozhina

    Although the duty cycle is an important parameter in pulsed plasma nitriding, its role in simultaneously controlling the microstructure, mechanical performance, tribological behavior, and corrosion resistance of 12Kh18N10T stainless steel remains insufficiently understood. Therefore, this study systematically investigates these relationships under otherwise fixed nitriding conditions. The samples were nitrided at 500 °C, a pressure of 400 Pa, a voltage of 700 V, and a treatment duration of 5 h, with duty cycle (DC) values of 30, 60, and 90%. The surface microstructure and composition were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and X-ray diffraction. The mechanical properties were evaluated by instrumented nanoindentation, the tribological properties were evaluated using the coefficient of friction and wear rate, and the corrosion resistance was investigated using potentiodynamic polarization. The maximum nitrided layer thickness of 91.29 μm was obtained at DC30, whereas the layer thickness at DC60 and DC90 was approximately 65.07 μm. Fe4N and Cr2N phases were identified in all samples. The DC60 regime provided the highest hardness of 740.6 HV, an elastic modulus of 215.9 GPa, the lowest coefficient of friction of 0.333, and the lowest corrosion current density of 0.000665 mA/cm2. The minimum wear rate of 2.276 × 10−5 mm3/(N·m) was achieved at DC90. These results show that the optimal processing condition depends on the required combination of hardness, wear resistance, coefficient of friction, and corrosion resistance. The obtained results demonstrate that the functional properties of the steel can be effectively tailored by controlling the duty cycle.

  • Open Access

    Structure, Corrosion, and Tribological Properties of TiON Coatings Prepared by Reactive Magnetron Sputtering for Potential Biomedical Surface Applications

    by Bauyrzhan Rakhadilov, Aidar Kengesbekov, Elvira Akhmetova, Arnur Askhatov

    This study investigates titanium oxynitride (TiOxNy) coatings deposited by reactive magnetron sputtering on 316L stainless steel substrates in an Ar–N2–O2 gas mixture at a fixed N:O ratio of 1.6. The coatings were deposited under three reactive magnetron sputtering regimes with Ar flow rates of 33, 28, and 26 sccm and corresponding substrate biases of −50, −100, and −150 V, respectively, while the N2 and O2 flow rates were kept constant at 10 and 6 sccm. The coatings exhibited a dense microstructure, with thicknesses ranging from 2.13 to 5.51 μm. X-ray diffraction analysis revealed the formation of a multiphase structure comprising TiN, TiOxNy, and TiO. The deposition regime had a significant influence on the functional properties of the coatings. The lowest friction coefficients (µ ≈ 0.26–0.28) and stable tribological behavior were characteristic of the Ar26 sample. The highest corrosion resistance was observed for the Ar28 sample, with a corrosion current density of icorr = 2.82 × 10−7 A/cm2 and a corrosion rate of vcorr = 0.00573 mm/year. All coatings exhibited hydrophilic surface behavior, with contact angles of 50–57°, which may be relevant for further evaluation in biomedical surface applications. Thus, the structure and functional properties of TiOxNy coatings can be regulated by selecting an appropriate deposition regime, including the Ar flow rate, relative reactive gas fraction, and substrate bias. However, additional biological tests, including cytotoxicity, hemocompatibility, endothelialization, and platelet adhesion studies, are required before conclusions about vascular implant applicability can be made.

  • Open Access

    Production of Pre-Alloyed Ti–6Al–4V Powders from Titanium Sponge via a Combined Mechanical Alloying and Hydrogenation–Dehydrogenation Process for Powder Metallurgy

    by Nazerke Serikkyzy, Zarina Aringozhina, Bauyrzhan Rakhadilov, Meruyert Adilkanova, Nurtoleu Magazov, Arnur Askhatov

    Ti–6Al–4V is the primary titanium alloy for aerospace, biomedical, and additive manufacturing applications; however, the high cost of powders produced by atomization limits their widespread adoption. This study aims to develop a cost-effective method for producing chemically homogeneous pre-alloyed Ti–6Al–4V powders from titanium sponge. A combined process is proposed, involving the hydrogenation of titanium sponge, mechanical alloying of the hydride phase with Al and V powders, and subsequent vacuum dehydrogenation. The formation of the brittle δ-TiH2 phase facilitated intensive material comminution and effective distribution of the alloying elements. According to laser diffraction data, the median particle size decreased from 450 to 30–35 µm. X-ray diffraction (XRD) analysis confirmed the sequential α-Ti → δ-TiH2 transition and the formation of a stable α + β two-phase structure characteristic of Ti–6Al–4V following dehydrogenation. SEM observations demonstrated that the final powders predominantly consist of individual fractured particles with limited hard agglomeration, favorable for powder flowability and compaction behavior. EDS analysis indicated a relatively homogeneous microscale distribution of Al and V without observable large-scale segregation. The synthesized powders exhibited low impurity levels, with O < 0.07 wt.% and H < 0.02 wt.%. The developed approach represents a promising and economical alternative to expensive atomization techniques for powder metallurgy and additive manufacturing.

  • Open Access

    The Effect of the Ar:N2:O2 Flow Ratio on the Structure, Hardness, and Adhesion of Thin TiON Films

    by Aidar Kengesbekov, Ainur Serikbaikyzy, Arnur Askhatov

    This study investigates the effect of the gas mixture composition ratio (Ar:N2:O2) during magnetron sputtering on the morphology, phase composition, and visual characteristics of TiNxOy thin films. Five different modes were used with a variable N2:O2 ratio ranging from 0.5 to 3. The resulting coatings exhibited noticeable differences in color—from golden to dark blue—which correlates with changes in chemical composition and phase state. The morphology of the films, examined by scanning electron microscopy (SEM), varied from a dense to a columnar structure. These results demonstrate that the properties of TiON coatings can be controlled by adjusting the N2:O2 ratio: nitrogen-rich conditions promote denser coatings with higher hardness and improved wear resistance, whereas a balanced N2:O2 ratio enhances coating adhesion to the substrate.


  • Open Access

    Investigation of the Effect of Preliminary Mechanical Treatment on the Mechanical Properties of 12Kh18N10T Stainless Steel After Ion-Plasma Nitriding

    by Zarina Aringozhina, Bauyrzhan Rakhadilov, Arnur Askhatov, Meruyert Adilkanova, Nurtoleu Magazov

    This study investigates the influence of preliminary severe plastic deformation on the efficiency of ion-plasma nitriding (IPN) and the formation of a nitrided layer in 12Kh18N10T austenitic stainless steel. Two types of surface mechanical treatment were compared: vibro-impact ball mechanical treatment (VIMT) and ultrasonic nanocrystalline surface modification (UNSM). After the preliminary treatments, the samples were subjected to ion-plasma nitriding at 500 °C for 10 h using ammonia (NH3) as the working gas. The phase composition, microstructure, elemental distribution, surface roughness, microhardness, and scratch resistance were analyzed using X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) analysis, profilometry, instrumented indentation, and progressive scratch testing. The results show that both types of preliminary treatment promote the formation of a nitrogen-enriched diffusion layer. The UNSM-treated samples exhibited more pronounced peak broadening and shifting in XRD patterns, indicating a higher level of lattice distortion and nitrogen supersaturation. The maximum nitrogen concentration in the near-surface region reached 15.56 wt.%. Microhardness increased significantly after nitriding for both treatments. Under the selected processing conditions, the UNSM + IPN samples demonstrated a thicker diffusion layer, lower surface roughness, and higher critical loads in scratch testing, indicating improved resistance to surface damage compared with VIMT + IPN samples. The obtained results highlight the important role of the defect structure formed during preliminary treatment in controlling nitrogen diffusion and the resulting mechanical and tribological properties of ion-plasma nitrided austenitic stainless steel.


  • Open Access

    Formation of Titanium Oxynitride Films by Reactive Magnetron Sputtering, Their Structural Features and Properties

    by Aidar Kengesbekov, Bauyrzhan Rakhadilov, Arystanbek Kussainov, Ainur Serikbaikyzy, Arnur Askhatov, Zarina Aringozhina

    TiOxNy coatings are known for their good biocompatibility and corrosion resistance and have been previously explored for biomedical applications, including cardiovascular stents. In this work, emphasis is placed on a systematic investigation of the effect of substrate bias voltage on the structural, morphological, and mechanical properties of TiOxNy films deposited by reactive magnetron sputtering. TiOxNy coatings were deposited on 316L stainless steel substrates using a pure titanium target (99.99%) in an Ar–N2–O2 gas mixture at various substrate bias voltages (0 to −150 V). The influence of substrate bias on the deposition rate, structure, and mechanical properties of the films was investigated. X-ray diffraction (XRD) analysis revealed the sequential phase evolution from cubic TiN to oxynitride TiON and further to TiO2 (anatase/rutile) with increasing negative substrate bias, indicating that ion bombardment energy plays a decisive role in determining the crystallinity and phase composition of the coatings. The coating deposited at −50 V exhibited the highest hardness (~430 HV) and good adhesion strength (critical load 20–25 N). Contact angle measurements confirmed the hydrophilic behavior of the coatings, which is favorable for biomedical applications.