Jie Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jie Yin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Lianxi Liu
Xidian University
2 shared publications - Xiangyi Liu
Xidian University
2 shared publications - Xufeng Liao
Xidian University
2 shared publications - Yinuo Zhang
Xidian University
2 shared publications - Zhangming Zhu
Xidian University
2 shared publications - Chenghao Zhou
Xidian University
1 shared publication
Latest Publications
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (4) , 2268-2278
A PVT-Insensitive and Wide EDO Elimination Range Bio-IA With Bulk-Driven Bias-Voltage-Adaptive-Adjustment OTA and Pre-Feedback ADSL
This paper presents a PVT-insensitive and wide electrode DC offset (EDO) elimination range bio-signal instrumentation amplifier (Bio-IA). A bulk-driven bias voltage adaptive adjustment (BD-VAA) OTA is proposed to effectively suppress the leakage current of the input transistors’ gate in the amplifier, thus stabilizing the bias voltage of the Bio-IA. In addition, a pre-feedback analog DC servo loop (PF-ADSL) based on an expanded input-stage (EIS) fully differential difference amplifier (DDA) buffer is proposed to increase the EDO elimination range. Each input stage in the DDA employs the improved parasitic capacitance shielding (IPCS) technique, which significantly enhances both the common-mode (CM) input impedance and the differential-mode (DM) input impedance. The Bio-IA is implemented based on a 65 nm CMOS process. Measurement results indicate that the input bias voltage of the Bio-IA is stable. The EDO elimination range of the Bio-IA is extended to $\pm ~240$ mV, the CM input impedance of the Bio-IA is as high as 39.9G $\Omega $ , and the DM input impedance reaches 5.2 G $\Omega $ .
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (4) , 2268-2278
A PVT-Insensitive and Wide EDO Elimination Range Bio-IA With Bulk-Driven Bias-Voltage-Adaptive-Adjustment OTA and Pre-Feedback ADSL
This paper presents a PVT-insensitive and wide electrode DC offset (EDO) elimination range bio-signal instrumentation amplifier (Bio-IA). A bulk-driven bias voltage adaptive adjustment (BD-VAA) OTA is proposed to effectively suppress the leakage current of the input transistors’ gate in the amplifier, thus stabilizing the bias voltage of the Bio-IA. In addition, a pre-feedback analog DC servo loop (PF-ADSL) based on an expanded input-stage (EIS) fully differential difference amplifier (DDA) buffer is proposed to increase the EDO elimination range. Each input stage in the DDA employs the improved parasitic capacitance shielding (IPCS) technique, which significantly enhances both the common-mode (CM) input impedance and the differential-mode (DM) input impedance. The Bio-IA is implemented based on a 65 nm CMOS process. Measurement results indicate that the input bias voltage of the Bio-IA is stable. The EDO elimination range of the Bio-IA is extended to $\pm ~240$ mV, the CM input impedance of the Bio-IA is as high as 39.9G $\Omega $ , and the DM input impedance reaches 5.2 G $\Omega $ .