AVAndrés Vega-Moraga

Andrés Vega-Moraga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrés Vega-Moraga has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel Ramos-López

    Metabolic Rehabilitation Unit, Center of Medical Specialties, Red de Salud UC Christus, Santiago 8330033, Chile

    2 shared publications
  • Felipe Contreras-Briceño

    Instituto de Ciencias de la Salud Universidad de O'Higgins Rancagua Chile

    2 shared publications
  • Raúl Caulier-Cisterna

    Department of Informatics and Computing, Faculty of Engineering, Universidad Tecnológica Metropolitana, Santiago, Chile

    2 shared publications
  • Benjamín Díaz‐Ortiz

    Laboratory of Exercise Physiology Department of Kinesiology School of Health Sciences Faculty of Medicine Pontificia Universidad Católica de Chile Santiago Chile

    1 shared publication
  • Cristóbal Baumann‐Biancani

    Laboratory of Exercise Physiology Department of Kinesiology School of Health Sciences Faculty of Medicine Pontificia Universidad Católica de Chile Santiago Chile

    1 shared publication
  • Hugo E. Verdejo

    Cardiovascular Signaling Laboratory, Division of Cardiovascular Diseases, Faculty of Medicine, Pontificia Universidad Católica de Chile

    1 shared publication

Latest Publications

  • Open Access

    The Effectiveness of NIRS-Based Wearable Devices in Estimating Physical Activity Intensity in Patients with Chronic Non-Communicable Diseases: A Structured Narrative Review

    by Raúl Caulier-Cisterna, Andrés Vega-Moraga, Daniel Ramos-López, Felipe Contreras-Briceño

    Background: Near-infrared spectroscopy (NIRS)-based wearable devices offer non-invasive, continuous monitoring of muscle oxygenation, providing direct microvascular and metabolic information that complements indirect indices of intensity such as heart rate and accelerometry. Their clinical applicability in chronic non-communicable diseases (NCDs) remains under active development. Methods: A structured narrative review was conducted in PubMed, Scopus, Web of Science, and IEEE Xplore (January 2010–January 2026) using pre-specified search strings combining NIRS, muscle oxygenation, SmO2, StO2, wearable, exercise intensity, ventilatory/lactate threshold, and individual chronic disease terms. Eligible studies addressed technical validation of wearable NIRS, NIRS-derived exercise intensity estimation, clinical applications in NCDs, or rehabilitation implementation. Evidence was synthesized thematically; quality of validation studies was appraised against AMSTAR-2-informed, COSMIN-informed, or Cochrane RoB-2 criteria. Results: Wearable continuous-wave NIRS shows acceptable concurrent validity with frequency-domain laboratory systems (r = 0.79; range 0.69–0.88; ±8% SmO2 agreement in 95% of measurements) and good test–retest reliability for moderate-to-severe domains (ICC 0.72–0.91). NIRS-derived breakpoints align more reliably with the second ventilatory/lactate threshold (ICC = 0.80) than with the first (ICC = 0.53), constraining its use for prescribing lower-intensity domains. In chronic obstructive pulmonary disease, peripheral arterial disease, chronic respiratory failure and selected cardiovascular conditions, wearable NIRS detects disease-specific patterns of muscle deoxygenation and post-exercise reoxygenation that track responses to rehabilitation. Conclusions: Current evidence supports wearable NIRS as a complementary, intensity-aware monitoring tool—particularly for delineating the heavy/severe-intensity boundary and detecting peripheral metabolic limitations—rather than as a stand-alone replacement for ventilatory or lactate thresholds. Because much of the evidence derives from small, single-sex or athlete-only cohorts, these findings should be regarded as a promising basis requiring further validation in broader NCD populations. Implementation in NCDs requires standardized placement and calibration protocols, sex- and body composition-stratified reference values, motion-artifact mitigation, and adequately powered longitudinal trials in clinical populations.

  • Open Access

    Sex differences in the prefrontal cortex and muscle oxygenation during exercise until exhaustion in endurance‐trained individuals

    by Daniel Ramos‐López, Raúl Caulier‐Cisterna, Benjamín Díaz‐Ortiz, Cristóbal Baumann‐Biancani, Kamilo Hunger‐Abbott, Matías Herrera‐Matas, Andrés Vega‐Moraga, Vitor A. Lira, Maximiliano Espinosa‐Ramírez, Karol Ramírez‐Parada, et al.

    Biological sex influences exercise performance, largely owing to anatomical and physiological differences in brain areas involved in cognitive motor control and in respiratory and locomotor muscles related to workload. We used near‐infrared spectroscopy data to examine sex differences in haemodynamic responses and oxygenation patterns in the prefrontal cortex (PFC), m. intercostales and m. vastus lateralis during incremental exercise in 74 endurance‐trained individuals. Changes (Δ) in oxyhaemoglobin (O 2 ‐Hb), deoxyhaemoglobin (H‐Hb) and tissue saturation index (TSI) were analysed using a two‐way ANOVA with the factors ‘sex’ and ‘intensity’. Effect sizes (ES) were also reported by partial eta squared (η p 2 ). Interactions were observed for ΔO 2 ‐Hb at the PFC [ p < 0.001, η p 2 = 0.42 (large ES)] and m. intercostales [ p < 0.001, η p 2 = 0.38 (large ES)], but not at m. vastus lateralis ( p = 0.160). For ΔH‐Hb, interactions were observed at m. vastus lateralis [ p < 0.001, η p 2 = 0.35 (large ES)] and the PFC [ p = 0.048, η p 2 = 0.18 (large ES)]. The ΔTSI also showed an interaction at m. vastus lateralis [ p < 0.001, η p 2 = 0.44 (large ES)] and a trend in the m. intercostales ( p = 0.057). Male subjects demonstrated greater oxygen delivery to the brain and increased peripheral deoxygenation, whereas females exhibited greater oxygen extraction in respiratory muscles, despite smaller body surface area. Higher tissue oxygen extraction reflects the capacity to meet local metabolic demands during exercise, enabling the identification of distinct oxygenation patterns between sexes. These findings suggest that sex‐specific mechanisms contribute to different patterns of physiological response to exercise. We support the hypothesis that peripheral factors might be more limiting in males, whereas in females central limitations (such as potential reduced oxygen delivery to the PFC owing to possible cerebral vasoconstriction triggered by metabolic reflexes) might play a more prominent role.