Hajime Oi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hajime Oi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Akira Matsumoto
Institute of Medical, Pharmaceutical and Health Sciences Kanazawa University Kanazawa Japan
2 shared publications - Ryota Kondo
The University of Tokyo, Tokyo, Japan
2 shared publications Seiko Suzuki
AGC Inc
2 shared publicationsYoshiichi Ozeki
AGC Inc
2 shared publications
Latest Publications
- 29 March 2022
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Evaluation of Equivalent Temperature in Vehicle Cabin by a Mesh-Free Simulation—Part 3: Evaluation of Equivalent Temperature under Transient Heating Condition
This paper describes the equivalent temperature based on the mesh-free simulation proposed by the previous papers (Part1 and Part2) under the transient heating condition in a 3D-CAD vehicle cabin including the thermal manikin which takes into account the clothing shape. For this purpose, firstly, the experiments of vehicle cabin measuring for the thermal environment including the equivalent temperature are carried out under the transient heating condition. Then, the calculated results of the thermal environment in the vehicle cabin are compared with time series experimental data under the transient condition. They correspond to the experiments including transient changes well. The transient calculated equivalent temperature of thermal manikin is also compared with experiments. As a result, since it is difficult to control the thermal manikin ideally in the experiment, it is difficult to compare the transient behavior. In particular, it is difficult to measure the amount of heat loss from the thermal manikin at the early stage of transient heating in the experiment. On the other hand, in the analysis, the thermal manikin can be controlled ideally so that the equivalent temperature can be evaluated including the transient condition. In this way, some differences between the actual phenomenon and the ideal situation can be confirmed under the transient behavior of the thermal manikin. Furthermore, effects of heat capacity of the clothing on the equivalent temperature are also studied. The behavior of the equivalent temperature calculated by the three types of setting methods for the heat capacity is different on the body segment of the thermal manikin of which heat capacity is large at the early stage of transient heating.
- 29 March 2022
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Evaluation of Equivalent Temperature in Vehicle Cabin by a Mesh-Free Simulation—Part 3: Evaluation of Equivalent Temperature under Transient Heating Condition
This paper describes the equivalent temperature based on the mesh-free simulation proposed by the previous papers (Part1 and Part2) under the transient heating condition in a 3D-CAD vehicle cabin including the thermal manikin which takes into account the clothing shape. For this purpose, firstly, the experiments of vehicle cabin measuring for the thermal environment including the equivalent temperature are carried out under the transient heating condition. Then, the calculated results of the thermal environment in the vehicle cabin are compared with time series experimental data under the transient condition. They correspond to the experiments including transient changes well. The transient calculated equivalent temperature of thermal manikin is also compared with experiments. As a result, since it is difficult to control the thermal manikin ideally in the experiment, it is difficult to compare the transient behavior. In particular, it is difficult to measure the amount of heat loss from the thermal manikin at the early stage of transient heating in the experiment. On the other hand, in the analysis, the thermal manikin can be controlled ideally so that the equivalent temperature can be evaluated including the transient condition. In this way, some differences between the actual phenomenon and the ideal situation can be confirmed under the transient behavior of the thermal manikin. Furthermore, effects of heat capacity of the clothing on the equivalent temperature are also studied. The behavior of the equivalent temperature calculated by the three types of setting methods for the heat capacity is different on the body segment of the thermal manikin of which heat capacity is large at the early stage of transient heating.
- 29 March 2022
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Evaluation of Equivalent Temperature Using Thermal Factors : Validation of a Calculation Method Based on ISO 14505-4:2021 in a Vehicle Cabin
This paper describes a method for evaluating the equivalent temperature in vehicle cabins based on the new international standard ISO 14505-4, published in 2021. ISO 14505-4 defines two simulation methods to determine a thermal comfort index “equivalent temperature.” One method uses a numerical thermal manikin, and the other uses thermal factors to calculate. This study discusses the latter method to validate its accuracy, identify the key points to consider, and examine its advantages and disadvantages. First, the definition of equivalent temperature and the equation to calculate the equivalent temperature using thermal factors, such as air temperature, radiant temperature, solar radiation, and air velocity, are explained. In addition, the experiments and simulation methods are described. In the experiments, the equivalent temperature was measured by a thermal manikin in a vehicle cabin under two conditions: a summer cooling condition with solar radiation and a winter heating condition without solar radiation. Subsequently, the thermal factors in the vehicle cabin under the experimental conditions were simulated using CFD. Next, the equivalent temperature was calculated using the thermal factors. Finally, the calculated equivalent temperatures are compared with those measured in the experiments and those calculated by the numerical thermal manikin method mentioned above. The results showed a good correlation at most segments, with approximately 4°C difference, indicating that thermal sensation can be predicted within an accuracy of 1 point on the ASHRAE 7-point scale. Air velocity treatment is critical for the segments where direct airflow hits, to accurately evaluate the equivalent temperature at each body segment. This method can also be used with 0D/1D tools such as thermal management simulations because it does not always require 3D models. In addition, this method can be easily applied to parametric studies.
- 29 March 2022
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Evaluation of Equivalent Temperature Using Thermal Factors : Validation of a Calculation Method Based on ISO 14505-4:2021 in a Vehicle Cabin
This paper describes a method for evaluating the equivalent temperature in vehicle cabins based on the new international standard ISO 14505-4, published in 2021. ISO 14505-4 defines two simulation methods to determine a thermal comfort index “equivalent temperature.” One method uses a numerical thermal manikin, and the other uses thermal factors to calculate. This study discusses the latter method to validate its accuracy, identify the key points to consider, and examine its advantages and disadvantages. First, the definition of equivalent temperature and the equation to calculate the equivalent temperature using thermal factors, such as air temperature, radiant temperature, solar radiation, and air velocity, are explained. In addition, the experiments and simulation methods are described. In the experiments, the equivalent temperature was measured by a thermal manikin in a vehicle cabin under two conditions: a summer cooling condition with solar radiation and a winter heating condition without solar radiation. Subsequently, the thermal factors in the vehicle cabin under the experimental conditions were simulated using CFD. Next, the equivalent temperature was calculated using the thermal factors. Finally, the calculated equivalent temperatures are compared with those measured in the experiments and those calculated by the numerical thermal manikin method mentioned above. The results showed a good correlation at most segments, with approximately 4°C difference, indicating that thermal sensation can be predicted within an accuracy of 1 point on the ASHRAE 7-point scale. Air velocity treatment is critical for the segments where direct airflow hits, to accurately evaluate the equivalent temperature at each body segment. This method can also be used with 0D/1D tools such as thermal management simulations because it does not always require 3D models. In addition, this method can be easily applied to parametric studies.