Abhishek Saini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Abhishek Saini has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Abhishek Sharma
Department of Mathematics, University of Delhi, Delhi, India
1 shared publication Ankur Vashishtha
Department of Medical Laboratory Technology, Sharda School of Allied Health Sciences, Sharda University, Greater Noida, Uttar Pradesh, 201310, India
1 shared publication- Aparna Vikal
Department of Nursing, IIMT University, Meerut, Uttar Pradesh, 250001, India
1 shared publication Aseem K. Tiwari
Department of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurgaon, Haryana, India
1 shared publication- Asha Yadav
Department of Nursing, IIMT University, Meerut, Uttar Pradesh, 250001, India
1 shared publication Chhavi Rajvanshi
Department of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurgaon, Haryana, India
1 shared publication
Latest Publications
- 25 March 2026
- Published by Bentham Science Publishers Ltd. in Current Materials Science
- Vol. 19
Fluoroscopic Imaging Redefined: A Detailed Review of C-Arm Technology and its Evolving Role
The C-Arm machine is an important medical imaging device, particularly in fluoroscopy. It can produce live X-radiation (X-ray) images and is utilized to guide a host of interventional and surgical procedures. Named for its arm shape, the device can be positioned around the patient to take images from numerous angles, which allows for tremendous operational precision. The C-Arm clinicians utilize in many areas of medicine, including Orthopaedic, neurosurgery, cardiology, gastroenterology, urology, and pain management. The C-Arm's versatility and portable, easy-to-handle design facilitate less invasive procedures that minimize the dependence on open operations and risks associated with them. Its use in minimally invasive surgery has spread very fast, thanks to its capacity for generating high-quality, real-time fluoroscopic images. Real-time visualization is crucial for the proper performance of procedures such as fracture fixation, catheter placement, nerve blocks, and stent placements. Latest developments, such as the use of flat panel detectors, have greatly enhanced image quality while reducing radiation exposure. In addition, newer models have incorporated 3D imaging features and artificial intelligence to allow their applications in more complicated procedures like spinal instrumentation, endoscopy, and robotic-assisted procedures. These advances only speak to the versatility of the C-Arm and its use across various specialties. Yet long-term or repeated exposure to radiation continues to be a concern for patients and medical professionals alike. In response, suppliers have added capabilities such as low-dose imaging and improved shielding to help reduce these risks. Enclosed and miniaturized versions are also enabling the use of C-Arms outside of traditional operating rooms, such as in emergency departments, outpatient clinics, and rural healthcare settings where imaging capabilities may be limited. The evolution of the C-Arm traces back to the discovery of X-rays in 1895 and the early fluoroscopes of the following year. With the introduction of image intensifiers in the mid-20th century and the digital transformations of the late 20th century, mobile CArms became a reality. Today’s systems, equipped with Artificial Intelligence (AI), 3D imaging, and robotics, continue to set new standards in surgical precision and safety.
- 25 March 2026
- Published by Bentham Science Publishers Ltd. in Current Materials Science
- Vol. 19
Fluoroscopic Imaging Redefined: A Detailed Review of C-Arm Technology and its Evolving Role
The C-Arm machine is an important medical imaging device, particularly in fluoroscopy. It can produce live X-radiation (X-ray) images and is utilized to guide a host of interventional and surgical procedures. Named for its arm shape, the device can be positioned around the patient to take images from numerous angles, which allows for tremendous operational precision. The C-Arm clinicians utilize in many areas of medicine, including Orthopaedic, neurosurgery, cardiology, gastroenterology, urology, and pain management. The C-Arm's versatility and portable, easy-to-handle design facilitate less invasive procedures that minimize the dependence on open operations and risks associated with them. Its use in minimally invasive surgery has spread very fast, thanks to its capacity for generating high-quality, real-time fluoroscopic images. Real-time visualization is crucial for the proper performance of procedures such as fracture fixation, catheter placement, nerve blocks, and stent placements. Latest developments, such as the use of flat panel detectors, have greatly enhanced image quality while reducing radiation exposure. In addition, newer models have incorporated 3D imaging features and artificial intelligence to allow their applications in more complicated procedures like spinal instrumentation, endoscopy, and robotic-assisted procedures. These advances only speak to the versatility of the C-Arm and its use across various specialties. Yet long-term or repeated exposure to radiation continues to be a concern for patients and medical professionals alike. In response, suppliers have added capabilities such as low-dose imaging and improved shielding to help reduce these risks. Enclosed and miniaturized versions are also enabling the use of C-Arms outside of traditional operating rooms, such as in emergency departments, outpatient clinics, and rural healthcare settings where imaging capabilities may be limited. The evolution of the C-Arm traces back to the discovery of X-rays in 1895 and the early fluoroscopes of the following year. With the introduction of image intensifiers in the mid-20th century and the digital transformations of the late 20th century, mobile CArms became a reality. Today’s systems, equipped with Artificial Intelligence (AI), 3D imaging, and robotics, continue to set new standards in surgical precision and safety.
- Open Access
- 7 June 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 14032-14037
study of hepatic function in multiple transfused thalassaemia patients
Background: Thalassemia syndomes are the most common genetic disorder on world wide basis . The selective pressures that have made the thalassemias so common are known but are assumed to relate to the geographic distrubution of malaria. Material & Methods: This was Prospective study conducted in the department of pediatrics in a teriary care hospital. The patients who had received m ore than 50 blood transfusions are considerd as multiple transfusion. Result: A total of 50 patients were enrolled in the study 90 % of patients were under 15 years of age male, female ratio was 1.27:1. The prevelance of thalassemia syndrome was common in sindhis and punjabis pupulation. Conculsion: The blood should be always screened for viral maricers, HIV and other blood born infections all thallsemai patients should be immunized with hepatitis B vaccine if patients are screnegative for HIV infection.
- 7 June 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 14032-14037
Open Accessstudy of hepatic function in multiple transfused thalassaemia patients
Background: Thalassemia syndomes are the most common genetic disorder on world wide basis . The selective pressures that have made the thalassemias so common are known but are assumed to relate to the geographic distrubution of malaria. Material & Methods: This was Prospective study conducted in the department of pediatrics in a teriary care hospital. The patients who had received m ore than 50 blood transfusions are considerd as multiple transfusion. Result: A total of 50 patients were enrolled in the study 90 % of patients were under 15 years of age male, female ratio was 1.27:1. The prevelance of thalassemia syndrome was common in sindhis and punjabis pupulation. Conculsion: The blood should be always screened for viral maricers, HIV and other blood born infections all thallsemai patients should be immunized with hepatitis B vaccine if patients are screnegative for HIV infection.
- Open Access
- 1 July 2021
- Published by Medknow in Indian Journal of Transplantation
- Vol. 15 (3) , 279-281
Pretransplant Compatibility Tests in Kidney Transplants
Pre-transplant compatibility work-up has evolved tremendously from conventional CDC only to CDC with more sensitive FCXM testing with bead-based assays (LMX and SAB). Detection of alloantibodies is one of the major objective in work-up algorithm. Conventionally cell-based tests were used, if both are negative, hospital usually proceeds for transplantation. If one of the screening tests (CDC/FCXM) is or both (CDC and FCXM) screening tests are positive, antibody identification is performed on Luminex platform to determine DSA by virtual cross-match. However, cell-based tests have their limitations. Here, we described a case which could have gone unnoticed if HLA bead-based assay was not there and could have triggered AMR (Antibody mediated rejection) as detected antibody (DRB1*07:01; BCM is 16416) was DSA.
- 1 July 2021
- Published by Medknow in Indian Journal of Transplantation
- Vol. 15 (3) , 279-281
Open AccessPretransplant Compatibility Tests in Kidney Transplants
Pre-transplant compatibility work-up has evolved tremendously from conventional CDC only to CDC with more sensitive FCXM testing with bead-based assays (LMX and SAB). Detection of alloantibodies is one of the major objective in work-up algorithm. Conventionally cell-based tests were used, if both are negative, hospital usually proceeds for transplantation. If one of the screening tests (CDC/FCXM) is or both (CDC and FCXM) screening tests are positive, antibody identification is performed on Luminex platform to determine DSA by virtual cross-match. However, cell-based tests have their limitations. Here, we described a case which could have gone unnoticed if HLA bead-based assay was not there and could have triggered AMR (Antibody mediated rejection) as detected antibody (DRB1*07:01; BCM is 16416) was DSA.