Jiukai Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiukai Tang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Jing Wang
ETH Zurich
6 shared publications - Guangyu Qiu
Shanghai Jiao Tong University
4 shared publications - Yi-Bo Zhao
Laboratory of Advanced Analytical Technologies, Empa, Dübendorf CH-8600, Switzerland
3 shared publications - Christian Ludwig
École Polytechnique Fédérale de Lausanne (EPFL)
2 shared publications - Tianyu Cen
Bioenergy and Catalysis Laboratory (LBK-CPM), Energy and Environment Research Division (ENE), Paul Scherrer Institut (PSI), Villigen PSI 5232, Switzerland
2 shared publications - Weidong He
School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, China
2 shared publications
Latest Publications
- Open Access
- 12 September 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (9) , 8296-8306
Quantifying Biomolecule Concentration of Phase-Separated Condensates in Optofluidic Chips
Liquid–liquid phase separation (LLPS) is a fundamental mechanism that drives biomolecular assembly. The concentration of biomolecules within phase-separated condensates is a critical parameter that reflects their physical state, modulates their biological functions, and provides insights into their formation and aging. However, current analytical methods, such as spectroscopy, fluorescence imaging, quantitative phase imaging, and bulk measurements, have limitations in quantifying biomolecule concentrations, involving measurement inaccuracies, sample perturbation, or requirements for large sample volumes. To overcome these challenges, we developed an optofluidic chip that integrates self-aligned micro-optics with a detection well. When LLPS components were mixed at stoichiometric ratios defined by their phase diagrams, condensates naturally formed, fused, and settled in the detection well. Consequently, the reflected light was modulated by the accumulated LLPS condensates on the sensing surface within the chip, enabling in situ, label-free, and reliable measurement of biomolecule concentrations in tiny volumes. Using this optofluidic platform, we quantified biomolecule concentrations for two model condensate systems and one virus-packaging-related condensate system, obtaining values of 168 ± 9 mg/mL for hyaluronic acid-protamine sulfate (HA-PT), 190 ± 13 mg/mL for polyadenylic acid-protamine sulfate (AA-PT), and 235 ± 23 mg/mL for the SARS-CoV-2 RNA SL4 fragment-nucleocapsid protein (SL4-NP). Given these quantitative capabilities, this optofluidic technique holds strong potential for characterizing how diverse LLPS systems evolve with concentration, such as pathological aging of condensates.
- 12 September 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (9) , 8296-8306
Open AccessQuantifying Biomolecule Concentration of Phase-Separated Condensates in Optofluidic Chips
Liquid–liquid phase separation (LLPS) is a fundamental mechanism that drives biomolecular assembly. The concentration of biomolecules within phase-separated condensates is a critical parameter that reflects their physical state, modulates their biological functions, and provides insights into their formation and aging. However, current analytical methods, such as spectroscopy, fluorescence imaging, quantitative phase imaging, and bulk measurements, have limitations in quantifying biomolecule concentrations, involving measurement inaccuracies, sample perturbation, or requirements for large sample volumes. To overcome these challenges, we developed an optofluidic chip that integrates self-aligned micro-optics with a detection well. When LLPS components were mixed at stoichiometric ratios defined by their phase diagrams, condensates naturally formed, fused, and settled in the detection well. Consequently, the reflected light was modulated by the accumulated LLPS condensates on the sensing surface within the chip, enabling in situ, label-free, and reliable measurement of biomolecule concentrations in tiny volumes. Using this optofluidic platform, we quantified biomolecule concentrations for two model condensate systems and one virus-packaging-related condensate system, obtaining values of 168 ± 9 mg/mL for hyaluronic acid-protamine sulfate (HA-PT), 190 ± 13 mg/mL for polyadenylic acid-protamine sulfate (AA-PT), and 235 ± 23 mg/mL for the SARS-CoV-2 RNA SL4 fragment-nucleocapsid protein (SL4-NP). Given these quantitative capabilities, this optofluidic technique holds strong potential for characterizing how diverse LLPS systems evolve with concentration, such as pathological aging of condensates.
- 28 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (22) , 16174-16183
Regression Models Enhance Fluorescence Spectra for Smart Surface Water Surveillance
Over the past three decades, fluorescence spectroscopy has been conventionally interpreted through peak picking, fluorescence regional integration, and parallel factor analysis to analyze aquatic dissolved organic matter. However, there is a growing need for advances in analytical toolkits to unlock the full potential of fluorescence spectra to tackle pressing challenges in smart water surveillance such as real-time surface water monitoring and wastewater source tracing. To this end, we established two types of easily implementable regression models. Through weighted linear regression (WLR), we constructed a novel correlation map for fluorescence excitation-emission matrices (EEMs) and dissolved organic carbon (DOC) based on 191 surface water samples from diverse aquatic environments. This map reveals that humic-like fluorescence intensity (FI) at excitation/emission wavelengths of 300-380/440-490 nm serves as a reliable indicator of aquatic DOC. In addition, a multivariable linear regression (MLR) model was developed to identify pharmaceutical wastewater blended into diverse surface water matrices, achieving fitting errors of 10-20%, despite fluorescence quenching at short excitation wavelengths. This work demonstrates that the regression-based toolkits developed herein can advance the application of fluorescence spectra for protecting aquatic environments.
- 28 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (22) , 16174-16183
Regression Models Enhance Fluorescence Spectra for Smart Surface Water Surveillance
Over the past three decades, fluorescence spectroscopy has been conventionally interpreted through peak picking, fluorescence regional integration, and parallel factor analysis to analyze aquatic dissolved organic matter. However, there is a growing need for advances in analytical toolkits to unlock the full potential of fluorescence spectra to tackle pressing challenges in smart water surveillance such as real-time surface water monitoring and wastewater source tracing. To this end, we established two types of easily implementable regression models. Through weighted linear regression (WLR), we constructed a novel correlation map for fluorescence excitation-emission matrices (EEMs) and dissolved organic carbon (DOC) based on 191 surface water samples from diverse aquatic environments. This map reveals that humic-like fluorescence intensity (FI) at excitation/emission wavelengths of 300-380/440-490 nm serves as a reliable indicator of aquatic DOC. In addition, a multivariable linear regression (MLR) model was developed to identify pharmaceutical wastewater blended into diverse surface water matrices, achieving fitting errors of 10-20%, despite fluorescence quenching at short excitation wavelengths. This work demonstrates that the regression-based toolkits developed herein can advance the application of fluorescence spectra for protecting aquatic environments.
- 10 November 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3521-3529
Microfluid Switching-Induced Transient Refractive Interface
The laminar flow interface (LFI) developed at low Reynolds numbers is one of the most prominent features of microscale flows and has been employed in a diverse range of optofluidic applications. The formation of LFIs usually requires the manipulation of multiple streams within a microchannel using a complex hydrodynamic pumping system. Herein, we present a new type of LFI that is generated by fluid switching within a three-dimensional (3D) microlens-incorporating microfluidic chip (3D-MIMC). Since Poiseuille flows exhibit a parabolic velocity profile, the LFI is cone-like in shape and acts as a transient refractive interface (TRI), which is sensitive to the refractive index (RI) and the Péclet number (Pe) of the switching fluids. In response to the TRI, the intensity of the transmitted light can be intensified or attenuated depending on the sequence of fluid switching operations. By incorporating three-dimensional (3D) microlenses and increasing the Pe values, the profile and amplitude of the intensity peak are both significantly improved. The limit of detection (LoD) for a sodium chloride (NaCl) solution at Pe = 1363 is as low as 0.001% (w/w), representing an improvement of 1-2 orders of magnitude when compared to existing optofluidic concentration sensors based on intensity modulation. Fluid switching of a variety of inorganic and organic sample fluids confirms that the specific optical response (Kor) correlates positively with both Pe and the specific RI (Knc), obeying a linear relationship. This model is further verified through cross-validations and used to estimate the molecular diffusion coefficient (D) of a range of species. Furthermore, by virtue of the TRI, we achieve a sensitive measurement of optical-equivalent total dissolved solids (OE-TDS) for environmental samples.
- 10 November 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3521-3529
Microfluid Switching-Induced Transient Refractive Interface
The laminar flow interface (LFI) developed at low Reynolds numbers is one of the most prominent features of microscale flows and has been employed in a diverse range of optofluidic applications. The formation of LFIs usually requires the manipulation of multiple streams within a microchannel using a complex hydrodynamic pumping system. Herein, we present a new type of LFI that is generated by fluid switching within a three-dimensional (3D) microlens-incorporating microfluidic chip (3D-MIMC). Since Poiseuille flows exhibit a parabolic velocity profile, the LFI is cone-like in shape and acts as a transient refractive interface (TRI), which is sensitive to the refractive index (RI) and the Péclet number (Pe) of the switching fluids. In response to the TRI, the intensity of the transmitted light can be intensified or attenuated depending on the sequence of fluid switching operations. By incorporating three-dimensional (3D) microlenses and increasing the Pe values, the profile and amplitude of the intensity peak are both significantly improved. The limit of detection (LoD) for a sodium chloride (NaCl) solution at Pe = 1363 is as low as 0.001% (w/w), representing an improvement of 1-2 orders of magnitude when compared to existing optofluidic concentration sensors based on intensity modulation. Fluid switching of a variety of inorganic and organic sample fluids confirms that the specific optical response (Kor) correlates positively with both Pe and the specific RI (Knc), obeying a linear relationship. This model is further verified through cross-validations and used to estimate the molecular diffusion coefficient (D) of a range of species. Furthermore, by virtue of the TRI, we achieve a sensitive measurement of optical-equivalent total dissolved solids (OE-TDS) for environmental samples.
- Open Access
- 30 October 2022
- Published by Wiley in Advanced Science
- Vol. 9 (35) , e2204774
On‐Site Quantification and Infection Risk Assessment of Airborne SARS‐CoV‐2 Virus Via a Nanoplasmonic Bioaerosol Sensing System in Healthcare Settings
On‐site quantification and early‐stage infection risk assessment of airborne severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) with high spatiotemporal resolution is a promising approach for mitigating the spread of coronavirus disease 2019 (COVID‐19) pandemic and informing life‐saving decisions. Here, a condensation (hygroscopic growth)‐assisted bioaerosol collection and plasmonic photothermal sensing (CAPS) system for on‐site quantitative risk analysis of SARS‐CoV‐2 virus‐laden aerosols is presented. The CAPS system provided rapid thermoplasmonic biosensing results after an aerosol‐to‐hydrosol sampling process in COVID‐19‐related environments including a hospital and a nursing home. The detection limit reached 0.25 copies/µL in the complex aerosol background without further purification. More importantly, the CAPS system enabled direct measurement of the SARS‐CoV‐2 virus exposures with high spatiotemporal resolution. Measurement and feedback of the results to healthcare workers and patients via a QR‐code are completed within two hours. Based on a dose‐responseµ model, it is used the plasmonic biosensing signal to calculate probabilities of SARS‐CoV‐2 infection risk and estimate maximum exposure durations to an acceptable risk threshold in different environmental settings.
- 30 October 2022
- Published by Wiley in Advanced Science
- Vol. 9 (35) , e2204774
Open AccessOn‐Site Quantification and Infection Risk Assessment of Airborne SARS‐CoV‐2 Virus Via a Nanoplasmonic Bioaerosol Sensing System in Healthcare Settings
On‐site quantification and early‐stage infection risk assessment of airborne severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) with high spatiotemporal resolution is a promising approach for mitigating the spread of coronavirus disease 2019 (COVID‐19) pandemic and informing life‐saving decisions. Here, a condensation (hygroscopic growth)‐assisted bioaerosol collection and plasmonic photothermal sensing (CAPS) system for on‐site quantitative risk analysis of SARS‐CoV‐2 virus‐laden aerosols is presented. The CAPS system provided rapid thermoplasmonic biosensing results after an aerosol‐to‐hydrosol sampling process in COVID‐19‐related environments including a hospital and a nursing home. The detection limit reached 0.25 copies/µL in the complex aerosol background without further purification. More importantly, the CAPS system enabled direct measurement of the SARS‐CoV‐2 virus exposures with high spatiotemporal resolution. Measurement and feedback of the results to healthcare workers and patients via a QR‐code are completed within two hours. Based on a dose‐responseµ model, it is used the plasmonic biosensing signal to calculate probabilities of SARS‐CoV‐2 infection risk and estimate maximum exposure durations to an acceptable risk threshold in different environmental settings.
- Open Access
- 30 January 2022
- Published by Elsevier in Separation and Purification Technology
- Vol. 287, 120590
An elution-based method for estimating efficiencies of aerosol collection devices not affected by their pressure drops
- 30 January 2022
- Published by Elsevier in Separation and Purification Technology
- Vol. 287, 120590
Open AccessAn elution-based method for estimating efficiencies of aerosol collection devices not affected by their pressure drops
- Open Access
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 351, 130903
Integrated aerodynamic/electrochemical microsystem for collection and detection of nanogram-level airborne bioaccessible metals
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 351, 130903
Open AccessIntegrated aerodynamic/electrochemical microsystem for collection and detection of nanogram-level airborne bioaccessible metals