Matthew E. Macasadia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matthew E. Macasadia has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Amanda J. Tijerina
Conceptual Mindworks, Inc., San Antonio, Texas, United States
3 shared publications - Gary D. Noojin
Air Force Research Laboratory 1 , JBSA Fort Sam Houston, Texas 78234
3 shared publications - Michael P. DeLisi
SAIC, JBSA-Fort Sam Houston 1 , Texas 78234
3 shared publications - Amanda M. Peterson
SAIC 1 , 4141 Petroleum Rd., JBSA Fort Sam Houston, Texas 78234
2 shared publications - Andrea L. Smith
SAIC, Joint Base San Antonio, Fort Sam Houston, Texas, United States
2 shared publications - Anjelyka Fasci
SAIC, JBSA Fort Sam Houston, Texas, United States
2 shared publications
Latest Publications
- Open Access
- 11 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (05) , 1-18
Corneal dose response from exposure to a Q-switched laser at a central wavelength of 1645 nm using a rabbit model
SignificanceLaser safety studies of the eye are well documented for visible wavelength and continuous wave lasers. There are fewer experimental results for infrared wavelengths and pulsed lasers.AimWe aim to fill the gap at 1645 nm for single nanosecond pulse duration exposures of rabbit cornea and determine the threshold radiant exposure to generate lesions 50% of the time (estimated dose ED50).ApproachImages of the cornea during exposures were acquired using slit lamp microscopy and optical coherence tomography. A histological analysis helped provide dosimetry relationships with morphology and mechanisms of the damage.ResultsWe measured the energy ED50 value at 3.86±0.085 mJ utilizing the slit lamp biomicroscopy. Incorporating the experimental spot size diameter, this corresponds to a peak radiant exposure of 102 J/cm2. By contrast, the average radiant exposure ED50 over a 1-mm diameter limiting aperture as per the ANSI Z.136 convention was 0.49 J/cm2. Additional analysis via optical coherence tomography (OCT) and histology examined the severity and degree of damage.ConclusionThis experimental approach performed well to characterize damage and identify damage thresholds to inform the laser safety standard community of the accuracy of current exposure limits.
- 11 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (05) , 1-18
Open AccessCorneal dose response from exposure to a Q-switched laser at a central wavelength of 1645 nm using a rabbit model
SignificanceLaser safety studies of the eye are well documented for visible wavelength and continuous wave lasers. There are fewer experimental results for infrared wavelengths and pulsed lasers.AimWe aim to fill the gap at 1645 nm for single nanosecond pulse duration exposures of rabbit cornea and determine the threshold radiant exposure to generate lesions 50% of the time (estimated dose ED50).ApproachImages of the cornea during exposures were acquired using slit lamp microscopy and optical coherence tomography. A histological analysis helped provide dosimetry relationships with morphology and mechanisms of the damage.ResultsWe measured the energy ED50 value at 3.86±0.085 mJ utilizing the slit lamp biomicroscopy. Incorporating the experimental spot size diameter, this corresponds to a peak radiant exposure of 102 J/cm2. By contrast, the average radiant exposure ED50 over a 1-mm diameter limiting aperture as per the ANSI Z.136 convention was 0.49 J/cm2. Additional analysis via optical coherence tomography (OCT) and histology examined the severity and degree of damage.ConclusionThis experimental approach performed well to characterize damage and identify damage thresholds to inform the laser safety standard community of the accuracy of current exposure limits.
- Open Access
- 14 January 2026
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Multiple-pulse laser damage thresholds in porcine skin at 1645 and 2090 nm
Infrared lasers with high repetition rates and pulse energies represent an emerging concern for laser safety given limited available exposure data. This study explored porcine skin response to 1645 and 2090 nm nanosecond-scale pulsed laser exposures at pulse repetition frequencies of 100, 300, and 1000 Hz. Numbers of pulses ranged from 60 to 1000, resulting in exposure durations between 0.06 and 10 s. The laser beam featured an average diameter of 0.45 and 0.77 cm (1/e2) at 1645 and 2090 nm, respectively. Skin minimum visible lesion (MVL) thresholds are reported 24 h postexposure and compared to the maximum permissible exposure (MPE) defined by the ANSI Z136.1-2022 standard. Safety factors range from 7.2 to 25.7 for 1645 nm and from 10.8 to 16.1 for 2090 nm, demonstrating adequacy of the MPE for these wavelengths. Data analysis at 1645 nm implies an intersection of the MVL threshold trend and the MPE at a total exposure duration of 300 μs, as the definition of the MPE between 1500 and 1800 nm is a static 1 J/cm2 with no dependence on exposure duration, unlike the 1800–2600 nm band. These results support consideration of a time-dependent MPE in the 1500–1800 nm range. Additionally, skin thermal response was lower at threshold levels compared to continuous-wave infrared laser skin studies and established critical temperature levels from Arrhenius assessments of skin damage. This could indicate induced thermoelastic stress lowering the temperature required for protein denaturation, implying the need for a more comprehensive rate process model for multiple-pulse laser skin damage.
- 14 January 2026
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Open AccessMultiple-pulse laser damage thresholds in porcine skin at 1645 and 2090 nm
Infrared lasers with high repetition rates and pulse energies represent an emerging concern for laser safety given limited available exposure data. This study explored porcine skin response to 1645 and 2090 nm nanosecond-scale pulsed laser exposures at pulse repetition frequencies of 100, 300, and 1000 Hz. Numbers of pulses ranged from 60 to 1000, resulting in exposure durations between 0.06 and 10 s. The laser beam featured an average diameter of 0.45 and 0.77 cm (1/e2) at 1645 and 2090 nm, respectively. Skin minimum visible lesion (MVL) thresholds are reported 24 h postexposure and compared to the maximum permissible exposure (MPE) defined by the ANSI Z136.1-2022 standard. Safety factors range from 7.2 to 25.7 for 1645 nm and from 10.8 to 16.1 for 2090 nm, demonstrating adequacy of the MPE for these wavelengths. Data analysis at 1645 nm implies an intersection of the MVL threshold trend and the MPE at a total exposure duration of 300 μs, as the definition of the MPE between 1500 and 1800 nm is a static 1 J/cm2 with no dependence on exposure duration, unlike the 1800–2600 nm band. These results support consideration of a time-dependent MPE in the 1500–1800 nm range. Additionally, skin thermal response was lower at threshold levels compared to continuous-wave infrared laser skin studies and established critical temperature levels from Arrhenius assessments of skin damage. This could indicate induced thermoelastic stress lowering the temperature required for protein denaturation, implying the need for a more comprehensive rate process model for multiple-pulse laser skin damage.
- Open Access
- 30 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Nanosecond multiple pulse ex vivo model of laser retinal damage
Pulsed lasers operating in the nanosecond time regime are increasingly used in a variety of applications, but safety data for the wide scope of laser parameters are limited. Specifically, repetition frequency, pulse duration, and wavelength may influence whether multiple successive pulses produce additive, synergistic, or interfering effects. Testing all these parameters in vivo would be costly and time consuming, while in vitro models lack the full complexity of the tissue composition and structure. An ex vivo model represents a happy medium between the two. Thus, the authors present a porcine ex vivo explant system to study nanosecond regime multiple pulse laser eye damage. The authors conducted laser exposures at 532 and 1064 nm, with pulse trains of 1, 10, 100, 1000, 10 000, and 20 000 pulses, and determined probit ED50 values for both wavelengths. Results from the 532 nm exposures were consistent with those from the previously published literature, and the trend was well fit by a probability summation model. Relative to 532 nm, exposures at 1064 nm revealed dramatic differences in lesion morphology and total energy required to induce damage, and the relationship between the total number of pulses and ED50 instead followed a logarithmic decrease. The authors demonstrate that this ex vivo model has the capability to reveal key insights underlying laser retinal damage mechanisms and represents a powerful tool for rapidly and affordably testing a wide variety of exposure conditions and how they influence the susceptibility of the retina to laser damage from multiple pulse exposures in the nanosecond time regime.
- 30 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Open AccessNanosecond multiple pulse ex vivo model of laser retinal damage
Pulsed lasers operating in the nanosecond time regime are increasingly used in a variety of applications, but safety data for the wide scope of laser parameters are limited. Specifically, repetition frequency, pulse duration, and wavelength may influence whether multiple successive pulses produce additive, synergistic, or interfering effects. Testing all these parameters in vivo would be costly and time consuming, while in vitro models lack the full complexity of the tissue composition and structure. An ex vivo model represents a happy medium between the two. Thus, the authors present a porcine ex vivo explant system to study nanosecond regime multiple pulse laser eye damage. The authors conducted laser exposures at 532 and 1064 nm, with pulse trains of 1, 10, 100, 1000, 10 000, and 20 000 pulses, and determined probit ED50 values for both wavelengths. Results from the 532 nm exposures were consistent with those from the previously published literature, and the trend was well fit by a probability summation model. Relative to 532 nm, exposures at 1064 nm revealed dramatic differences in lesion morphology and total energy required to induce damage, and the relationship between the total number of pulses and ED50 instead followed a logarithmic decrease. The authors demonstrate that this ex vivo model has the capability to reveal key insights underlying laser retinal damage mechanisms and represents a powerful tool for rapidly and affordably testing a wide variety of exposure conditions and how they influence the susceptibility of the retina to laser damage from multiple pulse exposures in the nanosecond time regime.
- 4 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Retinal dose response from exposure to the supercontinuum generated by a near-infrared femtosecond laser
Ultrashort pulse lasers are currently used in a variety of applications, including laser eye surgery. The 2022 revision to the American National Standards Institute laser safety standards includes maximum permissible exposures for pulses as short as 100 femtoseconds at ultraviolet, visible, and infrared wavelengths. However, the ocular laser safety standards do not consider nonlinear optical effects resulting from the interaction of ocular tissues with femtosecond pulses. The generation of broadband white light, or supercontinuum, is one example of a nonlinear optical effect resulting from the interaction of a femtosecond pulse with water. We have demonstrated supercontinuum generation within the eye of anesthetized porcine subjects and reported the median effective dose for laser-induced in vivo retinal damage from the supercontinuum generated by single femtosecond pulses at central wavelengths of 1325 and 1350 nm. We used a single near-infrared femtosecond pulse to determine the pulse energies that generated a supercontinuum within the eye and resulted in retinal alterations. We are now in a position to report our result for 1375 nm and on the histological analysis of the injuries. The results of this study will inform the laser safety standards’ community about hazards to the eye due to the supercontinuum generated by nonlinear effects in the aqueous media of the eye.
- 4 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38 (1)
Retinal dose response from exposure to the supercontinuum generated by a near-infrared femtosecond laser
Ultrashort pulse lasers are currently used in a variety of applications, including laser eye surgery. The 2022 revision to the American National Standards Institute laser safety standards includes maximum permissible exposures for pulses as short as 100 femtoseconds at ultraviolet, visible, and infrared wavelengths. However, the ocular laser safety standards do not consider nonlinear optical effects resulting from the interaction of ocular tissues with femtosecond pulses. The generation of broadband white light, or supercontinuum, is one example of a nonlinear optical effect resulting from the interaction of a femtosecond pulse with water. We have demonstrated supercontinuum generation within the eye of anesthetized porcine subjects and reported the median effective dose for laser-induced in vivo retinal damage from the supercontinuum generated by single femtosecond pulses at central wavelengths of 1325 and 1350 nm. We used a single near-infrared femtosecond pulse to determine the pulse energies that generated a supercontinuum within the eye and resulted in retinal alterations. We are now in a position to report our result for 1375 nm and on the histological analysis of the injuries. The results of this study will inform the laser safety standards’ community about hazards to the eye due to the supercontinuum generated by nonlinear effects in the aqueous media of the eye.
- Open Access
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 105003-18
Thermal damage induced changes in optical properties of the porcine dermis
Laser technology has improved modern medicine by enabling unprecedented precision in both diagnostic procedures and therapeutic interventions,1,2 transforming how clinicians approach patient care. With ongoing progress in laser technology, it is imperative to deepen our understanding of laser–tissue interactions, particularly concerning heat-induced damage. Laser-induced thermal damage to tissues is a complex process, involving coagulation and vaporization, which result in distinct layers of tissue damage.3 Accurately modeling these effects is necessary for predicting tissue responses to laser exposure. Although Monte Carlo simulations excel at optical modeling, they lack direct links to heat transfer and tissue damage kinetics, necessitating coupling with thermal models.4 – 6 Finite element multiphysics simulations, however, offer a more holistic approach by integrating heat transfer and damage accumulation, thus providing a comprehensive understanding of laser–tissue interactions.7 – 9
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 105003-18
Open AccessThermal damage induced changes in optical properties of the porcine dermis
Laser technology has improved modern medicine by enabling unprecedented precision in both diagnostic procedures and therapeutic interventions,1,2 transforming how clinicians approach patient care. With ongoing progress in laser technology, it is imperative to deepen our understanding of laser–tissue interactions, particularly concerning heat-induced damage. Laser-induced thermal damage to tissues is a complex process, involving coagulation and vaporization, which result in distinct layers of tissue damage.3 Accurately modeling these effects is necessary for predicting tissue responses to laser exposure. Although Monte Carlo simulations excel at optical modeling, they lack direct links to heat transfer and tissue damage kinetics, necessitating coupling with thermal models.4 – 6 Finite element multiphysics simulations, however, offer a more holistic approach by integrating heat transfer and damage accumulation, thus providing a comprehensive understanding of laser–tissue interactions.7 – 9
- Open Access
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (01) , 015001-14
Effects of cold storage on double integrating sphere optical property measurements of porcine dermis and subcutaneous fat from 400 to 1100 nm
In recent decades, remarkable progress has been made in utilizing lasers for medical applications, both in advancing diagnostic imaging systems and in therapeutic treatments.1 These advancements can be attributed, in part, to improvements in computational modeling,2 – 4 parallel processing,5 and, more recently, machine learning.6 Although computational models are becoming quite effective at predicting outcomes of laser-tissue interactions, these models are only as accurate as the physical measurements that inform them.7,8 More specifically, highly accurate measurements of the absorption coefficients, reduced scattering coefficients, and anisotropy of tissues are crucial, as these properties are known to be predictive of tissue morphology and biochemical composition.9
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (01) , 015001-14
Open AccessEffects of cold storage on double integrating sphere optical property measurements of porcine dermis and subcutaneous fat from 400 to 1100 nm
In recent decades, remarkable progress has been made in utilizing lasers for medical applications, both in advancing diagnostic imaging systems and in therapeutic treatments.1 These advancements can be attributed, in part, to improvements in computational modeling,2 – 4 parallel processing,5 and, more recently, machine learning.6 Although computational models are becoming quite effective at predicting outcomes of laser-tissue interactions, these models are only as accurate as the physical measurements that inform them.7,8 More specifically, highly accurate measurements of the absorption coefficients, reduced scattering coefficients, and anisotropy of tissues are crucial, as these properties are known to be predictive of tissue morphology and biochemical composition.9