Katarzyna Kulas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katarzyna Kulas has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jakub Szrama
Department of Anesthesiology, Intensive Therapy and Pain Management, Poznan University of Medical Sciences, 60-355 Poznan, Poland
2 shared publications - Mariusz Gezela
First Department of Anaesthesiology and Intensive Care, Poznan University of Medical Science, Poznan, Poland, Poland
2 shared publications - Paweł Sobczyński
Department of Anesthesiology, Intensive Therapy and Pain Management, Poznan University of Medical Sciences, Poznan, Poland; Department of Anesthesiology, Intensive Therapy and Pain Management Poznan University of Medical Sciences, Poznan, Poland, Poznań, Poland, Poland
2 shared publications - Łukasz Żurański
First Department of Anaesthesiology and Intensive Care, Poznan University of Medical Sciences, Poznan, Poland, Poland
2 shared publications - Michał Gajda
First Department of Anesthesiology and Intensive Therapy, Poznan University of Medical Sciences, 61-848 Poznan, Poland
1 shared publication - Piotr Smuszkiewicz
Department of Anesthesiology, Intensive Therapy and Pain Management, Poznan University of Medical Sciences, 60-355 Poznan, Poland
1 shared publication
Latest Publications
- Open Access
- 11 August 2026
- Published by MDPI AG in Preprints.org
Beyond Mean Arterial Pressure: A Retrospective Cohort Analysis of Pressure–Flow Dissociation and Postoperative Acute Kidney Injury in Major Aortic Surgery
Background/Objectives: Mean arterial pressure (MAP) is an incomplete surrogate of systemic perfusion: cardiac index (CI) and MAP can become dissociated. Recent cardiac surgery studies report that the burden of low CI during normotensive periods is associated with acute kidney injury (AKI). Whether this pressure--flow dissociation occurs in major aortic surgery and is modulated by the choice of arterial-pressure-derived monitoring strategy (FloTrac vs Acumen IQ/Hypotension Prediction Index, HPI) is unknown. Methods: CI-focused secondary analysis of 100 major aortic surgery patients from a prior MAP-based cohort. Continuous CI signals were newly extracted from the original HemoSphere exports. The primary metric was the percentage of monitoring time with CI2 during MAP$\geq$ 65mmHg; the primary outcome was AKI by KDIGO criteria. Multivariable logistic regression adjusted for baseline demographics, comorbidities, preoperative MAP, surgery duration, and monitoring strategy, with Holm–Bonferroni correction within test families. Reported per STROBE. Results: Pressure–flow dissociation was frequent: low CI during normotension occurred in 94% of patients at CI<2.5 (median burden 27%). The HPI group had numerically lower low-CI burden and higher mean MAP (87 vs 84mmHg, $p_{\mathrm{raw}} = 0.008$). AKI occurred in 34/99 evaluable patients (FloTrac 19/49, 38.8%; HPI 15/50, 30.0%). AKI patients did not have higher low CI burden than no-AKI patients (median 5.2% vs 7.6%, $p = 0.73$). In multivariable regression, neither low CI burden (adjusted OR 0.88 per 10-pp increase, 95% CI 0.67–1.12, $p = 0.33$) nor HPI assignment (adjusted OR 0.57, 95% CI 0.20--1.53, $p = 0.27$) was associated with AKI. Sensitivity, time-to-event, and heart rate × CI interaction analyses yielded uniformly null findings.Conclusions: Pressure–flow dissociation is frequent in major aortic surgery, and HPI monitoring modifies the haemodynamic pattern. However, neither the low CI burden nor the choice of monitoring strategy was associated with postoperative AKI, suggesting a boundary condition on the generalisability of recent cardiac surgery CI–AKI associations. Definitive evidence requires prospective randomised evaluation (HYPE-AORTA, NCT07510451).
- 11 August 2026
- Published by MDPI AG in Preprints.org
Open AccessBeyond Mean Arterial Pressure: A Retrospective Cohort Analysis of Pressure–Flow Dissociation and Postoperative Acute Kidney Injury in Major Aortic Surgery
Background/Objectives: Mean arterial pressure (MAP) is an incomplete surrogate of systemic perfusion: cardiac index (CI) and MAP can become dissociated. Recent cardiac surgery studies report that the burden of low CI during normotensive periods is associated with acute kidney injury (AKI). Whether this pressure--flow dissociation occurs in major aortic surgery and is modulated by the choice of arterial-pressure-derived monitoring strategy (FloTrac vs Acumen IQ/Hypotension Prediction Index, HPI) is unknown. Methods: CI-focused secondary analysis of 100 major aortic surgery patients from a prior MAP-based cohort. Continuous CI signals were newly extracted from the original HemoSphere exports. The primary metric was the percentage of monitoring time with CI2 during MAP$\geq$ 65mmHg; the primary outcome was AKI by KDIGO criteria. Multivariable logistic regression adjusted for baseline demographics, comorbidities, preoperative MAP, surgery duration, and monitoring strategy, with Holm–Bonferroni correction within test families. Reported per STROBE. Results: Pressure–flow dissociation was frequent: low CI during normotension occurred in 94% of patients at CI<2.5 (median burden 27%). The HPI group had numerically lower low-CI burden and higher mean MAP (87 vs 84mmHg, $p_{\mathrm{raw}} = 0.008$). AKI occurred in 34/99 evaluable patients (FloTrac 19/49, 38.8%; HPI 15/50, 30.0%). AKI patients did not have higher low CI burden than no-AKI patients (median 5.2% vs 7.6%, $p = 0.73$). In multivariable regression, neither low CI burden (adjusted OR 0.88 per 10-pp increase, 95% CI 0.67–1.12, $p = 0.33$) nor HPI assignment (adjusted OR 0.57, 95% CI 0.20--1.53, $p = 0.27$) was associated with AKI. Sensitivity, time-to-event, and heart rate × CI interaction analyses yielded uniformly null findings.Conclusions: Pressure–flow dissociation is frequent in major aortic surgery, and HPI monitoring modifies the haemodynamic pattern. However, neither the low CI burden nor the choice of monitoring strategy was associated with postoperative AKI, suggesting a boundary condition on the generalisability of recent cardiac surgery CI–AKI associations. Definitive evidence requires prospective randomised evaluation (HYPE-AORTA, NCT07510451).
- Open Access
- 12 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8791
Hypotension Prediction Index Software Compared with Standard Advanced Haemodynamic Monitoring in Patients Undergoing Major Aortic Surgery: A Retrospective Study
Background/Objectives: Intraoperative hypotension (IOH) is related to the occurrence of postoperative complications and may be a frequent event during major vascular surgery. The Hypotension Prediction Index (HPI) is a technology applied to predict hypotension and enable preventive interventions. This study aimed to compare intraoperative haemodynamic stability between patients monitored with the HPI algorithm and those monitored with arterial pressure cardiac output (APCO) monitoring. Methods: We performed a retrospective study including 100 adult patients undergoing elective major aortic surgery between January 2023 and June 2025. Fifty patients were managed with APCO monitoring and 50 with the HPI algorithm. The primary endpoint was time-weighted average mean arterial pressure below 65 mmHg (TWA-MAP < 65 mmHg). Secondary endpoints included total hypotension time, number and duration of hypotensive episodes, and time spent with MAP > 90 and > 100 mmHg. Multiple comparison correction (Holm–Bonferroni) was applied separately for hypotension and hypertension outcomes. Results: The primary outcome, TWA-MAP < 65 mmHg, did not differ significantly between groups (0.22 vs. 0.26 mmHg; ). After correction for multiple comparisons, no hypotension-related outcomes reached statistical significance, although clinically relevant trends were observed: the HPI group showed 50% shorter total hypotension time (5 vs. 10 min; , ) and 33% shorter episode duration. In contrast, patients in the HPI group spent significantly more time with elevated MAP: 38% vs. 25% of monitored time with MAP > 90 mmHg () and 18% vs. 9% with MAP > 100 mmHg (). Conclusions: In patients undergoing major vascular aortic surgery, HPI monitoring did not significantly reduce the burden of hypotension after accounting for multiple comparisons, though clinically meaningful trends were noted. However, HPI use was associated with significantly increased hypertensive exposure, suggesting overly aggressive correction. These findings highlight the need for careful titration of interventions when using predictive algorithms and warrant further prospective randomised studies.- 12 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8791
Open AccessHypotension Prediction Index Software Compared with Standard Advanced Haemodynamic Monitoring in Patients Undergoing Major Aortic Surgery: A Retrospective Study
Background/Objectives: Intraoperative hypotension (IOH) is related to the occurrence of postoperative complications and may be a frequent event during major vascular surgery. The Hypotension Prediction Index (HPI) is a technology applied to predict hypotension and enable preventive interventions. This study aimed to compare intraoperative haemodynamic stability between patients monitored with the HPI algorithm and those monitored with arterial pressure cardiac output (APCO) monitoring. Methods: We performed a retrospective study including 100 adult patients undergoing elective major aortic surgery between January 2023 and June 2025. Fifty patients were managed with APCO monitoring and 50 with the HPI algorithm. The primary endpoint was time-weighted average mean arterial pressure below 65 mmHg (TWA-MAP < 65 mmHg). Secondary endpoints included total hypotension time, number and duration of hypotensive episodes, and time spent with MAP > 90 and > 100 mmHg. Multiple comparison correction (Holm–Bonferroni) was applied separately for hypotension and hypertension outcomes. Results: The primary outcome, TWA-MAP < 65 mmHg, did not differ significantly between groups (0.22 vs. 0.26 mmHg; ). After correction for multiple comparisons, no hypotension-related outcomes reached statistical significance, although clinically relevant trends were observed: the HPI group showed 50% shorter total hypotension time (5 vs. 10 min; , ) and 33% shorter episode duration. In contrast, patients in the HPI group spent significantly more time with elevated MAP: 38% vs. 25% of monitored time with MAP > 90 mmHg () and 18% vs. 9% with MAP > 100 mmHg (). Conclusions: In patients undergoing major vascular aortic surgery, HPI monitoring did not significantly reduce the burden of hypotension after accounting for multiple comparisons, though clinically meaningful trends were noted. However, HPI use was associated with significantly increased hypertensive exposure, suggesting overly aggressive correction. These findings highlight the need for careful titration of interventions when using predictive algorithms and warrant further prospective randomised studies.