Nora Sultani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nora Sultani has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Natalia Kazimierczak
Kazimierczak Clinic, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland
3 shared publications - Wojciech Kazimierczak
Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
3 shared publications - Zbigniew Serafin
Faculty of Medicine, Bydgoszcz University of Science and Technology, Kaliskiego 7, 85-796 Bydgoszcz, Poland
3 shared publications - Natalia Chwarścianek
Independent Researcher, 87-100 Torun, Poland
2 shared publications - Aleksandra Ciszewska
Department of Maxillofacial Surgery, Poznan University of Medical Sciences, Przybyszewskiego 49, 60-355 Poznan, Poland
1 shared publication - Anna Lackowska
Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
1 shared publication
Latest Publications
- Open Access
- 28 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1667
Impact of Imaging Modality on AI-Based Detection of Incidental Maxillary Sinus Pathology: Comparison of Panoramic Radiography and CBCT
Background/Objectives: The objective of our study was to compare the diagnostic performance of a popular, commercial dental artificial intelligence (AI) platform (Diagnocat, DGNCT LLC, Miami, FL, USA) for detecting maxillary sinus abnormalities on paired panoramic radiographs (OPG) and cone-beam computed tomography (CBCT) acquired in the same patients, and to examine whether lesion conspicuity predicts correct AI decisions. Methods: In this retrospective paired study, 166 patients contributed 332 maxillary sinuses with OPG and CBCT performed ≤30 days apart. The reference standard was consensus CBCT reading by two observers with third-reader arbitration. The index test was the AI’s sinus-level binary output (any abnormality). Accuracy, precision, recall, and F1 score were estimated with patient-clustered 95% bootstrap CIs; secondary analyses assessed category-specific performance and the effect of mucosal thickness and polyp/cyst volume. Results: Our evaluation showed that the platform’s performance depended on modality. On CBCT, the accuracy was 69.88% (64.76–74.70%), precision was 87.83% (81.58–93.33%), recall was 54.01% (46.74–61.17%), and F1 score was 66.89% (60.34–72.84%). On OPG, the accuracy was 50.6% (44.58–55.41%), precision was 67.80% (55.38–79.66%), recall was 21.39% (15.62–27.32%), and F1 score 32.52% (24.79–39.69%). On CBCT, higher mucosal thickness and larger polyp/cyst volume strongly predicted correct AI calls; no such effect was seen with OPG. Conclusions: In conclusion, the evaluated AI showed high precision but only moderate recall on CBCT and unreliable performance on OPG. Outputs must be interpreted by a professional; AI alerts on OPG should not guide management without CBCT confirmation.
- 28 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1667
Open AccessImpact of Imaging Modality on AI-Based Detection of Incidental Maxillary Sinus Pathology: Comparison of Panoramic Radiography and CBCT
Background/Objectives: The objective of our study was to compare the diagnostic performance of a popular, commercial dental artificial intelligence (AI) platform (Diagnocat, DGNCT LLC, Miami, FL, USA) for detecting maxillary sinus abnormalities on paired panoramic radiographs (OPG) and cone-beam computed tomography (CBCT) acquired in the same patients, and to examine whether lesion conspicuity predicts correct AI decisions. Methods: In this retrospective paired study, 166 patients contributed 332 maxillary sinuses with OPG and CBCT performed ≤30 days apart. The reference standard was consensus CBCT reading by two observers with third-reader arbitration. The index test was the AI’s sinus-level binary output (any abnormality). Accuracy, precision, recall, and F1 score were estimated with patient-clustered 95% bootstrap CIs; secondary analyses assessed category-specific performance and the effect of mucosal thickness and polyp/cyst volume. Results: Our evaluation showed that the platform’s performance depended on modality. On CBCT, the accuracy was 69.88% (64.76–74.70%), precision was 87.83% (81.58–93.33%), recall was 54.01% (46.74–61.17%), and F1 score was 66.89% (60.34–72.84%). On OPG, the accuracy was 50.6% (44.58–55.41%), precision was 67.80% (55.38–79.66%), recall was 21.39% (15.62–27.32%), and F1 score 32.52% (24.79–39.69%). On CBCT, higher mucosal thickness and larger polyp/cyst volume strongly predicted correct AI calls; no such effect was seen with OPG. Conclusions: In conclusion, the evaluated AI showed high precision but only moderate recall on CBCT and unreliable performance on OPG. Outputs must be interpreted by a professional; AI alerts on OPG should not guide management without CBCT confirmation.
- Open Access
- 15 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (6) , 655-665
Automated tooth numbering on panoramic radiographs versus cone-beam computed tomographs: a diagnostic accuracy study of a commercial artificial intelligence system
Objectives: To assess the diagnostic accuracy of a commercial artificial intelligence system for automated tooth numbering on panoramic radiographs and cone-beam CT (CBCT) and to quantify case-level reliability. Methods: In this retrospective single-center diagnostic accuracy study, consecutive patients who underwent both panoramic radiography and CBCT in 2024 were included. The index test was automated tooth numbering generated by Diagnocat using the Fédération Dentaire Internationale numbering scheme. The reference standard was modality-specific consensus of 2 experienced, blinded readers. Tooth-position performance metrics with 95% confidence intervals were estimated using patient-level cluster bootstrap. Case-level reliability was defined as the proportion of examinations with completely error-free numbering across all evaluated tooth positions. Results: The study analyzed 171 paired panoramic radiographs and CBCT examinations, evaluating 4900 tooth positions per modality (9800 total). Tooth-position performance was identical and high across modalities (per-tooth accuracy 99.29% for both; overall position-based accuracy 98.73% [95% CI 97.97–99.38]). At the case level, 148/171 (86.5%) panoramic radiographs and 155/171 (90.6%) cone-beam computed tomography examinations were error-free. Conclusions: Despite high tooth-position metrics, approximately 1 in 10 to 1 in 7 examinations required at least one manual correction, demonstrating a gap between granular accuracy and case-level reliability. Advances in knowledge: Reporting case-level, error-free outputs alongside tooth-position metrics provides a more clinically meaningful estimate of reliability for automated tooth numbering and supports safer workflow implementation.
- 15 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (6) , 655-665
Open AccessAutomated tooth numbering on panoramic radiographs versus cone-beam computed tomographs: a diagnostic accuracy study of a commercial artificial intelligence system
Objectives: To assess the diagnostic accuracy of a commercial artificial intelligence system for automated tooth numbering on panoramic radiographs and cone-beam CT (CBCT) and to quantify case-level reliability. Methods: In this retrospective single-center diagnostic accuracy study, consecutive patients who underwent both panoramic radiography and CBCT in 2024 were included. The index test was automated tooth numbering generated by Diagnocat using the Fédération Dentaire Internationale numbering scheme. The reference standard was modality-specific consensus of 2 experienced, blinded readers. Tooth-position performance metrics with 95% confidence intervals were estimated using patient-level cluster bootstrap. Case-level reliability was defined as the proportion of examinations with completely error-free numbering across all evaluated tooth positions. Results: The study analyzed 171 paired panoramic radiographs and CBCT examinations, evaluating 4900 tooth positions per modality (9800 total). Tooth-position performance was identical and high across modalities (per-tooth accuracy 99.29% for both; overall position-based accuracy 98.73% [95% CI 97.97–99.38]). At the case level, 148/171 (86.5%) panoramic radiographs and 155/171 (90.6%) cone-beam computed tomography examinations were error-free. Conclusions: Despite high tooth-position metrics, approximately 1 in 10 to 1 in 7 examinations required at least one manual correction, demonstrating a gap between granular accuracy and case-level reliability. Advances in knowledge: Reporting case-level, error-free outputs alongside tooth-position metrics provides a more clinically meaningful estimate of reliability for automated tooth numbering and supports safer workflow implementation.
- Open Access
- 15 December 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (24) , 3207
AI-Based Detection of Dental Features on CBCT: Dual-Layer Reliability Analysis
Background/Objectives: Artificial intelligence (AI) systems may enhance diagnostic accuracy in cone-beam computed tomography (CBCT) analysis. However, most validations focus on isolated tooth-level tasks rather than clinically meaningful full-mouth assessment outcomes. To evaluate the diagnostic accuracy of a commercial AI platform for detecting dental treatment features on CBCT images at both tooth and full-scan levels. Methods: In this retrospective single-center study, 147 CBCT scans (4704 tooth positions) were analyzed. Two experienced readers annotated treatment features (missing teeth, fillings, endodontic treatments, crowns, pontics, orthodontic appliances, implants), and consensus served as the reference. Anonymized datasets were processed by a cloud-based AI system (Diagnocat Inc., San Francisco, CA, USA). Diagnostic metrics—sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score—were calculated with 95% patient-clustered bootstrap confidence intervals. A “Perfect Agreement” criterion defined full-scan level success as an entirely error-free full-mouth report. Results: Tooth-level AI performance was excellent, with accuracy exceeding 99% for most categories. Sensitivity was highest for missing teeth (99.3%) and endodontic treatments (99.0%). Specificity and NPV exceeded 98.5% and 99.7%, respectively. Full-scan level Perfect Agreement was achieved in 82.3% (95% CI: 76.2–88.4%), with errors concentrated in teeth presenting multiple co-existing findings. Conclusions: The evaluated AI platform demonstrates near-perfect accuracy in detecting isolated dental features but moderate reliability in generating complete full-mouth reports. It functions best as an assistive diagnostic tool, not as an autonomous system.
- 15 December 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (24) , 3207
Open AccessAI-Based Detection of Dental Features on CBCT: Dual-Layer Reliability Analysis
Background/Objectives: Artificial intelligence (AI) systems may enhance diagnostic accuracy in cone-beam computed tomography (CBCT) analysis. However, most validations focus on isolated tooth-level tasks rather than clinically meaningful full-mouth assessment outcomes. To evaluate the diagnostic accuracy of a commercial AI platform for detecting dental treatment features on CBCT images at both tooth and full-scan levels. Methods: In this retrospective single-center study, 147 CBCT scans (4704 tooth positions) were analyzed. Two experienced readers annotated treatment features (missing teeth, fillings, endodontic treatments, crowns, pontics, orthodontic appliances, implants), and consensus served as the reference. Anonymized datasets were processed by a cloud-based AI system (Diagnocat Inc., San Francisco, CA, USA). Diagnostic metrics—sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score—were calculated with 95% patient-clustered bootstrap confidence intervals. A “Perfect Agreement” criterion defined full-scan level success as an entirely error-free full-mouth report. Results: Tooth-level AI performance was excellent, with accuracy exceeding 99% for most categories. Sensitivity was highest for missing teeth (99.3%) and endodontic treatments (99.0%). Specificity and NPV exceeded 98.5% and 99.7%, respectively. Full-scan level Perfect Agreement was achieved in 82.3% (95% CI: 76.2–88.4%), with errors concentrated in teeth presenting multiple co-existing findings. Conclusions: The evaluated AI platform demonstrates near-perfect accuracy in detecting isolated dental features but moderate reliability in generating complete full-mouth reports. It functions best as an assistive diagnostic tool, not as an autonomous system.