NSNick Samuel

Nick Samuel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nick Samuel has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robust Passive Mechanical Filter for Sub-Hertz Seismic Detection on Venus

    by Cheng-Fu Chen, Mike Ophoff, Nick Samuel

    This study presents a passive mechanical filter designed to enhance sub-Hertz Venusquake detection by shaping the seismic transfer path. The mechanism uses a tunable, high-Q pendulum mounted inside a cylindrical enclosure on a three-ring gimbal to ensure self-leveling and alignment in gravity on uneven terrain. Unlike approaches that rely on broadband digitization and require active control and a stable power supply, this housing–gimbal mechanism performs mechanical filtering for sub-Hz signal amplification and higher frequency attenuation without power. Response spectrum analysis shows that the transmissibility can be tuned to achieve peak sensitivities in the 0.5–0.8 Hz range. When tuned to 50–55 mm pendulum length and under assumed undamping, the pendulum-mounted mechanism improves detectability at best by 10–100× relative to a bare sensor for moderate magnitude (Ms = 3–6) in a 12 h observation window, with signal-to-noise (SNR) ratio of 3, and amplitude spectrum density (ASD) of 10−8 m/s2/√Hz. Furthermore, we extrapolate that the predicted minimum detectable event rates follow Nmmin∝SNR1.2ASD1.2fs0.6, where fs is the quake wave frequency. The damping ratio, considering both structural damping and viscous drag, is estimated to be in the order of 10−3 to 10−2. A probabilistic sensitivity analysis is performed to account for the inherent uncertainty in the spectral mismatch between the narrowband sub-Hz resonance of the designed mechanical filter and the peak frequencies of seismic events; the derived probability model suggests strategies for improving the detection probability in the 0.01–1 Hz range.

  • Open Access

    Robust Passive Mechanical Filter for Sub-Hertz Seismic Detection on Venus

    by Cheng-Fu Chen, Mike Ophoff, Nick Samuel

    This study presents a passive mechanical filter designed to enhance sub-Hertz Venusquake detection by shaping the seismic transfer path with a tunable, high-Q pendulum mounted inside a cylindrical enclosure on a three-ring gimbal. The gimbal provides self-leveling on uneven terrain, while the housing–gimbal assembly remains broadband-stiff (s = 3-6) in a 12-h observation window, with signal-to-noise (SNR) ratio of 3, and amplitude spectrum density (ASD) of 10⁻⁸ m/s²/√Hz. Furthermore, we extrapolate that the predicted minimum detectable event rates follow Nmmin∝(SNR)1.2(ASD)1.2fs0.6, where fs is the quake wave frequency. A limitation is the quasi-static regime (0.05 Hz or below), where rigid-body motion overrides the benefit. Overall, the passive, power-free architecture offers a robust alternative to existing Venus Lander designs, enabling sub-Hz detection even during short-duration surface operations while adhering to mission constraints.