Chen Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chen Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Xin Tong
Chinese Academy of Sciences
2 shared publications - Lin Li
Huaihua University
1 shared publication - Wen-Cui Peng
Innovation Academy for Precision Measurement Science and Technology Chinese Academy of Sciences Wuhan 430071 People's Republic of China
1 shared publication Wen-Li Bai
State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, People’s Republic of China
1 shared publicationWen-Ting Gan
State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, People’s Republic of China
1 shared publication- Wen-Ting Gan
Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences 1 , Wuhan 430071
1 shared publication
Latest Publications
- Open Access
- 30 December 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (2) , 025205
Probing extreme-high vacuum in cryogenic ion traps using Be + Coulomb crystals
We demonstrate the precise in situ measurement of extreme-high vacuum (XHV) in a cryogenic linear Paul trap operating at 5.7 K, utilizing laser-cooled Be + Coulomb crystals as dual-mode quantum probes. Two independent methods, elastic collision rate monitoring and reaction rate analysis, were employed to determine the vacuum level within the cryogenic linear Paul trap. Based on the collision rate of a single trapped beryllium ion with background gas, which was measured as 1.3(7) × 10 −4 Hz, the pressure under cryogenic conditions was calculated to be 6.0(3.4) × 10 −12 Pa. Alternatively, by leveraging the reaction rate of Be + ions with background gases, a pressure of 8.4(1) × 10 −12 Pa was obtained. The mutual agreement between these two methods validates the reliability of cold-atom-based vacuum metrology at the 10 −12 Pa scale, successfully overcoming the detection limits of conventional vacuum gauges. This approach, which capitalizes on the unique mass properties and photostability of Be + ions, fills a critical gap in XHV metrology and paves the way for the development of chip-trap-integrated in situ vacuum sensing technologies.
- 30 December 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (2) , 025205
Open AccessProbing extreme-high vacuum in cryogenic ion traps using Be + Coulomb crystals
We demonstrate the precise in situ measurement of extreme-high vacuum (XHV) in a cryogenic linear Paul trap operating at 5.7 K, utilizing laser-cooled Be + Coulomb crystals as dual-mode quantum probes. Two independent methods, elastic collision rate monitoring and reaction rate analysis, were employed to determine the vacuum level within the cryogenic linear Paul trap. Based on the collision rate of a single trapped beryllium ion with background gas, which was measured as 1.3(7) × 10 −4 Hz, the pressure under cryogenic conditions was calculated to be 6.0(3.4) × 10 −12 Pa. Alternatively, by leveraging the reaction rate of Be + ions with background gases, a pressure of 8.4(1) × 10 −12 Pa was obtained. The mutual agreement between these two methods validates the reliability of cold-atom-based vacuum metrology at the 10 −12 Pa scale, successfully overcoming the detection limits of conventional vacuum gauges. This approach, which capitalizes on the unique mass properties and photostability of Be + ions, fills a critical gap in XHV metrology and paves the way for the development of chip-trap-integrated in situ vacuum sensing technologies.
- Open Access
- 9 December 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (22)
Trapping and sympathetic cooling of Th3+ ions in a linear ion trap
We demonstrate a modified integration of a linear ion trap with a time-of-flight mass spectrometer optimized to enhance the loading and detection of Th3+ ions. A phase-locked radiofrequency/high-voltage switch incorporating zero-crossing triggering and a programmable time delay is a key upgrade to minimize RF phase-dependent jitter and enable the unambiguous identification of Th3+ ions. To enhance purity, yield, and lifetime of trapped Th3+ ions, we optimize the ion loading parameters, including ion trap settings (RF amplitude, endcap voltages, and loading time), laser-ablation pulse energy, helium partial pressure, and ion storage time. These improvements extend trapping lifetimes of Th3+ ions to several hundred seconds, representing an order-of-magnitude increase compared to our previous work. Finally, single-pulse ablation of mixed Sr–Th nitrate targets enables the direct co-loading of Th3+ and 88Sr+ ions, and subsequent laser cooling forms multi-component Coulomb crystals for laser spectroscopy of Th3+ ions. Given the long trapping lifetime of Th3+ ions, this system will serve as a platform for developing a prototype trap-based thorium nuclear clock.
- 9 December 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (22)
Open AccessTrapping and sympathetic cooling of Th3+ ions in a linear ion trap
We demonstrate a modified integration of a linear ion trap with a time-of-flight mass spectrometer optimized to enhance the loading and detection of Th3+ ions. A phase-locked radiofrequency/high-voltage switch incorporating zero-crossing triggering and a programmable time delay is a key upgrade to minimize RF phase-dependent jitter and enable the unambiguous identification of Th3+ ions. To enhance purity, yield, and lifetime of trapped Th3+ ions, we optimize the ion loading parameters, including ion trap settings (RF amplitude, endcap voltages, and loading time), laser-ablation pulse energy, helium partial pressure, and ion storage time. These improvements extend trapping lifetimes of Th3+ ions to several hundred seconds, representing an order-of-magnitude increase compared to our previous work. Finally, single-pulse ablation of mixed Sr–Th nitrate targets enables the direct co-loading of Th3+ and 88Sr+ ions, and subsequent laser cooling forms multi-component Coulomb crystals for laser spectroscopy of Th3+ ions. Given the long trapping lifetime of Th3+ ions, this system will serve as a platform for developing a prototype trap-based thorium nuclear clock.