Chang Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chang Cheng has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Weiwei Qu
State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, China
4 shared publications - Xiaoyu Xu
School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, China
4 shared publications - Gao-Long Zhang
Beihang University
2 shared publications Gaolong Zhang
Beihang University
2 shared publications- Zhen Huang
School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, China
2 shared publications - B. R. Gonçalves
Beihang University
1 shared publication
Latest Publications
- 8 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (19) , 195025
Study of three-dimensional dose distribution measurement of ultra-high dose rate electron beam
Objective . FLASH radiotherapy which employs an ultra-high dose rate (UHDR) ( > 40 Gy s − 1 ), effectively protects normal tissues and organs while maintaining robust tumor control. However, it also presents serious challenges for quality assurance (QA). Currently, dosimeters face various limitations under FLASH radiotherapy conditions which make it difficult to meet the demand for rapid and high-precision three-dimensional (3D) dose verification. In this paper, CMOS cameras were used to capture luminescence images generated by irradiated water and for 3D dose reconstruction. Approach . A tri-orthogonal view camera imaging setup was designed and constructed to collect radioluminescence signals in water phantom. The ordered subsets expectation maximization iterative algorithm was adopted to obtain 3D dose reconstruction. The experiments were performed by 6 MV and 10 MV conventional dose rate x-rays, as well as 9 MeV electron with an UHDR of 120 Gy s − 1 . The dose distribution was verified by treatment planning system calculations and film measurements, respectively. Quantitative evaluations were performed through percentage depth dose (PDD), lateral dose profiles, and two-dimensional gamma analysis (3%/3 mm, 10% threshold). Results . The luminescence intensity of water phantom shows high linearity with the irradiation dose and exhibits independent characteristics with dose rate. The PDD curve of conventional x-ray reconstruction underestimates the dose in the dose fall-off region, and the transverse dose distribution shows high consistency with the reference distribution. Under different irradiation fields, the difference in the full width at half maximum (FWHM) of the lateral dose distribution curves at each depth is less than 1.25 mm. The PDD curve of the UHDR electron beam reconstruction result underestimates the dose in the shallow region. The deviation of the half-peak dose depth from the film measurement result is less than 0.7 mm. Calculations of the gamma passing rate on each plane of the reconstruction result indicate that the method used shows high accuracy for the transverse distribution. Significance . The proposed 3D dose distribution measurement method is applicable to both conventional dose rate radiotherapy and UHDR radiotherapy conditions. It demonstrates favourable performance when evaluating lateral parameters including field shape, field size, flatness and uniformity, which is promising for field consistency verification in clinical UHDR radiotherapy QA.
- 8 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (19) , 195025
Study of three-dimensional dose distribution measurement of ultra-high dose rate electron beam
Objective . FLASH radiotherapy which employs an ultra-high dose rate (UHDR) ( > 40 Gy s − 1 ), effectively protects normal tissues and organs while maintaining robust tumor control. However, it also presents serious challenges for quality assurance (QA). Currently, dosimeters face various limitations under FLASH radiotherapy conditions which make it difficult to meet the demand for rapid and high-precision three-dimensional (3D) dose verification. In this paper, CMOS cameras were used to capture luminescence images generated by irradiated water and for 3D dose reconstruction. Approach . A tri-orthogonal view camera imaging setup was designed and constructed to collect radioluminescence signals in water phantom. The ordered subsets expectation maximization iterative algorithm was adopted to obtain 3D dose reconstruction. The experiments were performed by 6 MV and 10 MV conventional dose rate x-rays, as well as 9 MeV electron with an UHDR of 120 Gy s − 1 . The dose distribution was verified by treatment planning system calculations and film measurements, respectively. Quantitative evaluations were performed through percentage depth dose (PDD), lateral dose profiles, and two-dimensional gamma analysis (3%/3 mm, 10% threshold). Results . The luminescence intensity of water phantom shows high linearity with the irradiation dose and exhibits independent characteristics with dose rate. The PDD curve of conventional x-ray reconstruction underestimates the dose in the dose fall-off region, and the transverse dose distribution shows high consistency with the reference distribution. Under different irradiation fields, the difference in the full width at half maximum (FWHM) of the lateral dose distribution curves at each depth is less than 1.25 mm. The PDD curve of the UHDR electron beam reconstruction result underestimates the dose in the shallow region. The deviation of the half-peak dose depth from the film measurement result is less than 0.7 mm. Calculations of the gamma passing rate on each plane of the reconstruction result indicate that the method used shows high accuracy for the transverse distribution. Significance . The proposed 3D dose distribution measurement method is applicable to both conventional dose rate radiotherapy and UHDR radiotherapy conditions. It demonstrates favourable performance when evaluating lateral parameters including field shape, field size, flatness and uniformity, which is promising for field consistency verification in clinical UHDR radiotherapy QA.
- 16 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9) , 186
Feasibility study of thermal neutron/proton detection in a lunar surface-like environment using Cs2LiYCl6:Ce detector
- 16 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9) , 186
Feasibility study of thermal neutron/proton detection in a lunar surface-like environment using Cs2LiYCl6:Ce detector
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
First investigation of the Bi 209 ( Li 6 , Li 7 * → α + t ) Bi * 208 breakup channel
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
First investigation of the Bi 209 ( Li 6 , Li 7 * → α + t ) Bi * 208 breakup channel
- Open Access
- 8 January 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (1) , 3
Key Considerations for Treatment Planning System Development in Electron and Proton FLASH Radiotherapy
The global cancer burden continues to increase worldwide. Among the various treatment options, radiotherapy (RT), which employs high-energy ionizing radiation to destroy cancer cells, is one of the primary modalities for cancer. However, increasing the absorbed dose to the target volume also increases the risk of damage to surrounding healthy tissues. This radiation-induced toxicity to normal tissues limits the desirable dosage that can be delivered to the tumor, thereby constraining the effectiveness of radiation therapy in achieving tumor control. FLASH radiotherapy (FLASH-RT) has emerged as a promising technique due to its biological advantages. FLASH-RT involves the delivery of radiation at an ultra-high dose rate (≥40 Gy/s). Unlike conventional RT, FLASH-RT achieves comparable tumor control rates while significantly reducing damage to surrounding normal tissues, a phenomenon known as the FLASH effect. Although the mechanism behind the FLASH effect is not fully understood, this approach shows considerable promise for future cancer treatment. The development of specialized treatment planning systems (TPS) becomes imperative to facilitate the clinical implementation of FLASH-RT from experimental studies. These systems must account for the unique characteristics of FLASH-RT, including ultra-high dose rate delivery and its distinctive radiobiological effects. Critical reassessment and optimization of treatment planning protocols are essential to fully leverage the therapeutic potential of the FLASH effect. This review examines key considerations for the TPS development of electron and proton FLASH-RT, including electron and proton FLASH techniques, biological models, crucial beam parameters, and dosimetry, providing essential insights for optimizing TPS and advancing the clinical implementation of this promising therapeutic modality.
- 8 January 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (1) , 3
Open AccessKey Considerations for Treatment Planning System Development in Electron and Proton FLASH Radiotherapy
The global cancer burden continues to increase worldwide. Among the various treatment options, radiotherapy (RT), which employs high-energy ionizing radiation to destroy cancer cells, is one of the primary modalities for cancer. However, increasing the absorbed dose to the target volume also increases the risk of damage to surrounding healthy tissues. This radiation-induced toxicity to normal tissues limits the desirable dosage that can be delivered to the tumor, thereby constraining the effectiveness of radiation therapy in achieving tumor control. FLASH radiotherapy (FLASH-RT) has emerged as a promising technique due to its biological advantages. FLASH-RT involves the delivery of radiation at an ultra-high dose rate (≥40 Gy/s). Unlike conventional RT, FLASH-RT achieves comparable tumor control rates while significantly reducing damage to surrounding normal tissues, a phenomenon known as the FLASH effect. Although the mechanism behind the FLASH effect is not fully understood, this approach shows considerable promise for future cancer treatment. The development of specialized treatment planning systems (TPS) becomes imperative to facilitate the clinical implementation of FLASH-RT from experimental studies. These systems must account for the unique characteristics of FLASH-RT, including ultra-high dose rate delivery and its distinctive radiobiological effects. Critical reassessment and optimization of treatment planning protocols are essential to fully leverage the therapeutic potential of the FLASH effect. This review examines key considerations for the TPS development of electron and proton FLASH-RT, including electron and proton FLASH techniques, biological models, crucial beam parameters, and dosimetry, providing essential insights for optimizing TPS and advancing the clinical implementation of this promising therapeutic modality.
- 29 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015009
New method for online quality control of dwell position and dwell time in brachytherapy by using high-speed camera and neural networks
Objective. To develop an online quality control (QC) system for accurate assessment of dwell position and dwell time in high-dose-rate (HDR) brachytherapy, and to investigate the potential of neural networks so as to improve the robustness and stability of the proposed system. Approach. An integrated framework was constructed using a Basler high-speed camera (144 fps, 1920 × 1200 pixels), custom illumination, and dedicated software. Experiments were conducted with a GammaMedPlus iX afterloader equipped with a stepping 192 Ir source, testing various step sizes (0.2 cm, 0.5 cm, 1.0 cm) and dwell times (2.0 s, 3.0 s, 10.0 s). The core online algorithm employed a frame-difference method for source tracking, while offline analysis evaluated the RT-DETRv2 neural network for source localization. Main results. The system achieved high spatial resolution (0.083 mm) and temporal resolution (7.0 ms). Primarily due to guidewire bending, positional deviations remained below 0.1 cm and increased with guidewire length. After position correction, the positional deviation was reduced to about 0.01 cm. Dwell time deviations were within 10.0 ms. RT-DETRv2 demonstrated outstanding localization accuracy (91% of predictions within 0.26 mm) in various conditions. However, its processing latency of 0.35 s per image makes it unsuitable for online monitoring but well-suited for offline or auxiliary verification in this system. Significance. This work presented a technically feasible online QC method for HDR brachytherapy that enabled precise verification of source delivery parameters. Moreover, the successful application of deep learning for source detection established a foundation for future enhancements in reliability and automation of the proposed QC system.
- 29 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015009
New method for online quality control of dwell position and dwell time in brachytherapy by using high-speed camera and neural networks
Objective. To develop an online quality control (QC) system for accurate assessment of dwell position and dwell time in high-dose-rate (HDR) brachytherapy, and to investigate the potential of neural networks so as to improve the robustness and stability of the proposed system. Approach. An integrated framework was constructed using a Basler high-speed camera (144 fps, 1920 × 1200 pixels), custom illumination, and dedicated software. Experiments were conducted with a GammaMedPlus iX afterloader equipped with a stepping 192 Ir source, testing various step sizes (0.2 cm, 0.5 cm, 1.0 cm) and dwell times (2.0 s, 3.0 s, 10.0 s). The core online algorithm employed a frame-difference method for source tracking, while offline analysis evaluated the RT-DETRv2 neural network for source localization. Main results. The system achieved high spatial resolution (0.083 mm) and temporal resolution (7.0 ms). Primarily due to guidewire bending, positional deviations remained below 0.1 cm and increased with guidewire length. After position correction, the positional deviation was reduced to about 0.01 cm. Dwell time deviations were within 10.0 ms. RT-DETRv2 demonstrated outstanding localization accuracy (91% of predictions within 0.26 mm) in various conditions. However, its processing latency of 0.35 s per image makes it unsuitable for online monitoring but well-suited for offline or auxiliary verification in this system. Significance. This work presented a technically feasible online QC method for HDR brachytherapy that enabled precise verification of source delivery parameters. Moreover, the successful application of deep learning for source detection established a foundation for future enhancements in reliability and automation of the proposed QC system.