Patimat Kamaludinovna Murtazalieva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patimat Kamaludinovna Murtazalieva has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Sergey Vladimirovich Kostenev
S.N. Fyodorov Eye Microsurgery Federal State Institution of the Russian Ministry of Health of the Russian Federation
5 shared publications - Aila Azretovna Uyanaeva
S. Fyodorov Eye Microsurgery Federal State Institution
2 shared publications - Anastasia Evgenevna Nikitina
Russian University of Medicine
2 shared publications - A. Yu. Slonimskiy
Moscow Eye Clinic
1 shared publication - E. A. Shikhalieva
S. Fyodorov Eye Microsurgery Federal State Institution
1 shared publication - E.V. Kim
S.N. Fedorov NMRC «MNTK «Eye Microsurgery», Ministry of Health of Russia, Moscow , Russia
1 shared publication
Latest Publications
- Open Access
- 15 November 2026
- Published by ECO-Vector LLC (Publications) in Journal of Clinical Practice
- Vol. 17 (3) , 157-162
Surgical correction of residual ametropia caused by incomplete removal of lenticular tissue after CLEAR surgery: а clinical case
BACKGROUND: Extraction of an intrastromal lenticule formed with a femtosecond laser through a small incision is an effective method for correcting myopia and myopic astigmatism. The main intraoperative complication noted during refractive extraction of the lenticule is the loss of vacuum between the interface and the patient's cornea. To prevent ocular displacement and maintain the axis during treatment of severe astigmatism, the cornea is stabilized using pericorneal aspiration, which prevents occlusion of the surgical site. If aspiration is lost, decentration risks occurring, and the rotational movement of the eye causes the astigmatic axis to shift. This leads to a weak lenticule cut and incomplete removal. CLINICAL CASE DESCRIPTION: A revision of the surgical site was performed in the Refractive Surgery Department of the Eye Microsurgery Scientific and Technical Complex in Moscow, successfully eliminating residual ametropia after refractive lenticule extraction. CONCLUSION: Early correction (1–2 weeks after the initial surgery) is appropriate when residual lenticular tissue is minimal and refraction is stable, minimizing the risk of further changes. Incomplete removal of lenticular tissue and subsequent residual ametropia represent a significant clinical problem requiring a comprehensive approach. In the presented clinical case, surgical removal of residual lenticular tissue during a repeat revision of the surgical site eliminated the ametropia and restored visual function.
- 15 November 2026
- Published by ECO-Vector LLC (Publications) in Journal of Clinical Practice
- Vol. 17 (3) , 157-162
Open AccessSurgical correction of residual ametropia caused by incomplete removal of lenticular tissue after CLEAR surgery: а clinical case
BACKGROUND: Extraction of an intrastromal lenticule formed with a femtosecond laser through a small incision is an effective method for correcting myopia and myopic astigmatism. The main intraoperative complication noted during refractive extraction of the lenticule is the loss of vacuum between the interface and the patient's cornea. To prevent ocular displacement and maintain the axis during treatment of severe astigmatism, the cornea is stabilized using pericorneal aspiration, which prevents occlusion of the surgical site. If aspiration is lost, decentration risks occurring, and the rotational movement of the eye causes the astigmatic axis to shift. This leads to a weak lenticule cut and incomplete removal. CLINICAL CASE DESCRIPTION: A revision of the surgical site was performed in the Refractive Surgery Department of the Eye Microsurgery Scientific and Technical Complex in Moscow, successfully eliminating residual ametropia after refractive lenticule extraction. CONCLUSION: Early correction (1–2 weeks after the initial surgery) is appropriate when residual lenticular tissue is minimal and refraction is stable, minimizing the risk of further changes. Incomplete removal of lenticular tissue and subsequent residual ametropia represent a significant clinical problem requiring a comprehensive approach. In the presented clinical case, surgical removal of residual lenticular tissue during a repeat revision of the surgical site eliminated the ametropia and restored visual function.
- 27 May 2026
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 11 (2) , 174-186
The first clinical and functional results of mixed astigmatism correction with femtosecond lenticular technology
Background . Mixed astigmatism is one of the most difficult refractive errors to correct. Traditional excimer laser techniques are associated with the risk of biomechanical complications due to the formation of a corneal flap. Lenticular technology offers a minimally invasive alternative, but its application in the case of mixed astigmatism is not well-studied and requires the development of specialized surgical approaches. The aim . To evaluate the effectiveness of early clinical and functional results in the correction of mixed astigmatism using femtosecond lenticular technology. Methods and materials . The study included 10 patients (15 eyes) aged 32.4 ± 6.13 years with mixed astigmatism. Following a comprehensive preoperative examination, all patients underwent refractive lenticule extraction using the SMILE method using a VisuMax™ 500 kHz femtosecond laser (Carl Zeiss Meditec AG) with preliminary calculation of lenticule parameters using the developed technology. Postoperative monitoring was performed on the 1st day, 1 week, and 1 month. Results . After one month, the uncorrected visual acuity was 0.90 ± 0.11, corresponding to the preoperative best-corrected visual acuity (0.90 ± 0.18). The spherical equivalent stabilized at 0.06 ± 0.45 D. The cylindrical component decreased from -2.77 ± 0.79 D to -0.22 ±0.47 D. Keratometry readings decreased from 42.59 ±1.56 D to 40.80 ±1.08 D. Central corneal thickness decreased to 499.53 ± 34.27 µm (baseline: 555.87 ± 33.02 µm) while maintaining residual stroma at 376.27 ± 32.50 µm. No additional correction or complications were required. Conclusion . The developed technology for correcting mixed astigmatism based on refractive parameter transposition in lenticular surgery is effective and safe – high visual function was achieved in the early postoperative period with minimal risk of complications and preserved biomechanical stability of the cornea, confirming the potential for further research.
- 27 May 2026
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 11 (2) , 174-186
The first clinical and functional results of mixed astigmatism correction with femtosecond lenticular technology
Background . Mixed astigmatism is one of the most difficult refractive errors to correct. Traditional excimer laser techniques are associated with the risk of biomechanical complications due to the formation of a corneal flap. Lenticular technology offers a minimally invasive alternative, but its application in the case of mixed astigmatism is not well-studied and requires the development of specialized surgical approaches. The aim . To evaluate the effectiveness of early clinical and functional results in the correction of mixed astigmatism using femtosecond lenticular technology. Methods and materials . The study included 10 patients (15 eyes) aged 32.4 ± 6.13 years with mixed astigmatism. Following a comprehensive preoperative examination, all patients underwent refractive lenticule extraction using the SMILE method using a VisuMax™ 500 kHz femtosecond laser (Carl Zeiss Meditec AG) with preliminary calculation of lenticule parameters using the developed technology. Postoperative monitoring was performed on the 1st day, 1 week, and 1 month. Results . After one month, the uncorrected visual acuity was 0.90 ± 0.11, corresponding to the preoperative best-corrected visual acuity (0.90 ± 0.18). The spherical equivalent stabilized at 0.06 ± 0.45 D. The cylindrical component decreased from -2.77 ± 0.79 D to -0.22 ±0.47 D. Keratometry readings decreased from 42.59 ±1.56 D to 40.80 ±1.08 D. Central corneal thickness decreased to 499.53 ± 34.27 µm (baseline: 555.87 ± 33.02 µm) while maintaining residual stroma at 376.27 ± 32.50 µm. No additional correction or complications were required. Conclusion . The developed technology for correcting mixed astigmatism based on refractive parameter transposition in lenticular surgery is effective and safe – high visual function was achieved in the early postoperative period with minimal risk of complications and preserved biomechanical stability of the cornea, confirming the potential for further research.
- Open Access
- 7 April 2026
- Published by Mediprint in POINT OF VIEW. EAST – WEST
- Vol. 13 (1) , 44-48
Clinical results of refractive lensectomy in patients with moderate and high degree hypermetropia
Hypermetropia is a common refractive anomaly affecting a significant part of the population. In modern practice, phacoemulsification followed by implantation of an intraocular lens (IOL) is becoming increasingly popular as a method of correcting farsightedness due to the development of microinvasive technologies and new IOL models. Refractive lensectomy research is mainly focused on age groups over 45–50 years old, which requires a study of efficacy and safety in young and middle-aged patients. Purpose. To evaluate the clinical efficacy and safety of refractive lensectomy followed by multifocal IOL implantation in young and middle-aged patients suffering from moderate and high degree hypermetropia. Material and methods. A retrospective clinical trial was conducted, where the data of 20 patients (40 eyes) with moderate and high-grade hypermetropia, aged from 23 to 50 years, were analyzed. All patients underwent refractive lensectomy with multifocal IOL implantation (AcrySof IQ PanOptix or Alcon Clareon PanOptix). Results. Preoperative hypermetropic refraction averaged 4.75±1.5 D (2.25–8.5 D), NCOSIS — 0.2±0.19 (0.03–0.8), MKOZ — 0.8±0.23 (0.25–1.0). After surgery, the refractive index averaged 0.08±0.28 D, visual acuity without correction increased from 0.2 to 0.8 on a verage. The planned emmetropia was achieved in 87.5% of the eyes. Conclusion. A retrospective study confirms the efficacy and safety of phacoemulsification of the crystalline lens with the implantation of a multifocal IOL for the correction of moderate and high degree hypermetropia. The safety of the procedure is confirmed by the absence of cases of a decr ease in the MCI by more than one line. Keywords: hypermetropia, phacoemulsification, multifocal intraocular lenses, refractive lens exchange
- 7 April 2026
- Published by Mediprint in POINT OF VIEW. EAST – WEST
- Vol. 13 (1) , 44-48
Open AccessClinical results of refractive lensectomy in patients with moderate and high degree hypermetropia
Hypermetropia is a common refractive anomaly affecting a significant part of the population. In modern practice, phacoemulsification followed by implantation of an intraocular lens (IOL) is becoming increasingly popular as a method of correcting farsightedness due to the development of microinvasive technologies and new IOL models. Refractive lensectomy research is mainly focused on age groups over 45–50 years old, which requires a study of efficacy and safety in young and middle-aged patients. Purpose. To evaluate the clinical efficacy and safety of refractive lensectomy followed by multifocal IOL implantation in young and middle-aged patients suffering from moderate and high degree hypermetropia. Material and methods. A retrospective clinical trial was conducted, where the data of 20 patients (40 eyes) with moderate and high-grade hypermetropia, aged from 23 to 50 years, were analyzed. All patients underwent refractive lensectomy with multifocal IOL implantation (AcrySof IQ PanOptix or Alcon Clareon PanOptix). Results. Preoperative hypermetropic refraction averaged 4.75±1.5 D (2.25–8.5 D), NCOSIS — 0.2±0.19 (0.03–0.8), MKOZ — 0.8±0.23 (0.25–1.0). After surgery, the refractive index averaged 0.08±0.28 D, visual acuity without correction increased from 0.2 to 0.8 on a verage. The planned emmetropia was achieved in 87.5% of the eyes. Conclusion. A retrospective study confirms the efficacy and safety of phacoemulsification of the crystalline lens with the implantation of a multifocal IOL for the correction of moderate and high degree hypermetropia. The safety of the procedure is confirmed by the absence of cases of a decr ease in the MCI by more than one line. Keywords: hypermetropia, phacoemulsification, multifocal intraocular lenses, refractive lens exchange
- 1 April 2026
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 28 (1)
Development of a machine learning model for predicting myopia progression in children wearing peripheral defocus spectacle lenses
Background . Myopia remains one of the leading causes of visual impairment worldwide. A wide range of therapeutic and preventive strategies is currently applied in clinical practice to slow myopia progression. In recent years, increasing attention has been directed toward the use of artificial intelligence (AI) for predicting disease progression and treatment outcomes. Machine learning techniques enable the development of predictive models based on baseline clinical data, thereby improving individualized treatment planning. Purpose : To develop and validate a machine learning model for predicting myopia progression at the 12-month follow-up in children wearing peripheral defocus spectacle lenses. Materials and methods . A dataset comprising 48 eyes of 48 pediatric patients fitted with peripheral defocus spectacle lenses was analyzed. Binary classification models were developed using Python 3 and the scikit-learn, XGBoost, and LightGBM libraries. Eight machine learning algorithms were evaluated: XGBoost, Random Forest, Gradient Boosting, LightGBM, Extra Trees, Logistic Regression, Decision Tree, and K-Nearest Neighbors. The outcome variable was defined as a binary indicator of treatment effectiveness: favorable outcome (24 eyes) – annual myopia progression less than −1.00 diopters at 12 months; unfavorable outcome (24 eyes) – progression of −1.00 diopters or greater. The dataset was divided into training and test sets in a 67:33 ratio. Feature importance was assessed using built-in feature importance methods. Results . The highest predictive performance on the test dataset was demonstrated by the XGBoost model, with a ROC AUC of 0.906. The model achieved an accuracy of 0.875, sensitivity of 0.875, and specificity of 0.875. The most influential predictors of treatment outcome were: minimum keratometry (Kmin) at baseline (0.382), baseline spherical equivalent refraction (0.217), baseline corneal radius of curvature (0.184), baseline axial length (0.102), patient age (0.064), and maximum keratometry (Kmax) at baseline (0.051). Conclusion . The proposed machine learning model demonstrated excellent predictive performance for forecasting the outcome of peripheral defocus spectacle lens wear in children at the 12-month follow-up. A clinical decision-support calculator based on this model has been developed for practical application.
- 1 April 2026
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 28 (1)
Development of a machine learning model for predicting myopia progression in children wearing peripheral defocus spectacle lenses
Background . Myopia remains one of the leading causes of visual impairment worldwide. A wide range of therapeutic and preventive strategies is currently applied in clinical practice to slow myopia progression. In recent years, increasing attention has been directed toward the use of artificial intelligence (AI) for predicting disease progression and treatment outcomes. Machine learning techniques enable the development of predictive models based on baseline clinical data, thereby improving individualized treatment planning. Purpose : To develop and validate a machine learning model for predicting myopia progression at the 12-month follow-up in children wearing peripheral defocus spectacle lenses. Materials and methods . A dataset comprising 48 eyes of 48 pediatric patients fitted with peripheral defocus spectacle lenses was analyzed. Binary classification models were developed using Python 3 and the scikit-learn, XGBoost, and LightGBM libraries. Eight machine learning algorithms were evaluated: XGBoost, Random Forest, Gradient Boosting, LightGBM, Extra Trees, Logistic Regression, Decision Tree, and K-Nearest Neighbors. The outcome variable was defined as a binary indicator of treatment effectiveness: favorable outcome (24 eyes) – annual myopia progression less than −1.00 diopters at 12 months; unfavorable outcome (24 eyes) – progression of −1.00 diopters or greater. The dataset was divided into training and test sets in a 67:33 ratio. Feature importance was assessed using built-in feature importance methods. Results . The highest predictive performance on the test dataset was demonstrated by the XGBoost model, with a ROC AUC of 0.906. The model achieved an accuracy of 0.875, sensitivity of 0.875, and specificity of 0.875. The most influential predictors of treatment outcome were: minimum keratometry (Kmin) at baseline (0.382), baseline spherical equivalent refraction (0.217), baseline corneal radius of curvature (0.184), baseline axial length (0.102), patient age (0.064), and maximum keratometry (Kmax) at baseline (0.051). Conclusion . The proposed machine learning model demonstrated excellent predictive performance for forecasting the outcome of peripheral defocus spectacle lens wear in children at the 12-month follow-up. A clinical decision-support calculator based on this model has been developed for practical application.
- 14 December 2025
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 27 (4)
Corneal lenticular surgery using the monovision technique: First experience
Background. Monovision is a well-established method for presbyopia correction in which the dominant eye is corrected for distance vision, while the non-dominant eye is adjusted for near vision. Initially developed for contact lens correction, this approach has subsequently been adapted for use in refractive surgery. To date, no reports have been found describing the application of the monovision concept in myopic presbyopic patients undergoing laser vision correction using the Corneal Lenticule Extraction for Advanced Refractive Correction (CLEAR) technique, which underscores the relevance of the present study. Purpose: to evaluate the functional outcomes of the monovision technique following lenticule extraction in myopic patients of presbyopic age. Materials and methods . The study included 20 patients (40 eyes), divided into two groups of 20 eyes each. The mean patient age was 40.6 ± 2.7 years. The study was conducted at the Department of Laser Refractive Surgery, S. Fedorov Eye Microsurgery Federal State Institution, from July to December 2024. In Group 1, surgery was performed using the CLEAR technique with the monovision approach, leaving a residual myopia of 1.25–1.75 D in the non-dominant eye. Group 2 underwent standard CLEAR surgery. All patients had mild to moderate myopia and a preoperative best-corrected visual acuity (BCVA) of at least 1.0. Before surgery, postoperative visual acuity was simulated with soft contact lenses, and a comprehensive ophthalmological examination, including binocular vision assessment, was performed. In both groups, the femtosecond laser FEMTO LDV Z8 (Ziemer, Switzerland) was used. Distance and near visual acuity, type of vision, and visual fields were evaluated before and after surgery. The follow-up period was three months. Results. Postoperatively, uncorrected distance visual acuity (UDVA) improved in both eyes in Group 1, though it was slightly lower in the non-dominant eye (0.98 and 0.76, respectively). In Group 2, UDVA improved to 0.99 and 0.96, respectively. The target refraction was achieved in all cases without loss of BCVA and remained stable throughout the follow-up. The postoperative values of UDVA, BCVA, and spherical equivalent showed no significant change over time. Near visual acuity was evaluated binocularly—preoperatively with maximum distance correction and postoperatively without correction. In Group 1 (monovision), postoperative uncorrected near visual acuity (UNVA) increased to 0.99 – 1.0, whereas in Group 2 it reached only 0.37. Binocular vision was preserved in all patients, and visual field parameters remained within normal limits before and after surgery in all cases. Conclusion. Corneal lenticule extraction using the CLEAR technique with the monovision approach provides high postoperative visual acuity at both distance and near in presbyopic myopic patients while maintaining binocular and peripheral vision.
- 14 December 2025
- Published by Academy of Medical Optics and Optometry in The EYE GLAZ
- Vol. 27 (4)
Corneal lenticular surgery using the monovision technique: First experience
Background. Monovision is a well-established method for presbyopia correction in which the dominant eye is corrected for distance vision, while the non-dominant eye is adjusted for near vision. Initially developed for contact lens correction, this approach has subsequently been adapted for use in refractive surgery. To date, no reports have been found describing the application of the monovision concept in myopic presbyopic patients undergoing laser vision correction using the Corneal Lenticule Extraction for Advanced Refractive Correction (CLEAR) technique, which underscores the relevance of the present study. Purpose: to evaluate the functional outcomes of the monovision technique following lenticule extraction in myopic patients of presbyopic age. Materials and methods . The study included 20 patients (40 eyes), divided into two groups of 20 eyes each. The mean patient age was 40.6 ± 2.7 years. The study was conducted at the Department of Laser Refractive Surgery, S. Fedorov Eye Microsurgery Federal State Institution, from July to December 2024. In Group 1, surgery was performed using the CLEAR technique with the monovision approach, leaving a residual myopia of 1.25–1.75 D in the non-dominant eye. Group 2 underwent standard CLEAR surgery. All patients had mild to moderate myopia and a preoperative best-corrected visual acuity (BCVA) of at least 1.0. Before surgery, postoperative visual acuity was simulated with soft contact lenses, and a comprehensive ophthalmological examination, including binocular vision assessment, was performed. In both groups, the femtosecond laser FEMTO LDV Z8 (Ziemer, Switzerland) was used. Distance and near visual acuity, type of vision, and visual fields were evaluated before and after surgery. The follow-up period was three months. Results. Postoperatively, uncorrected distance visual acuity (UDVA) improved in both eyes in Group 1, though it was slightly lower in the non-dominant eye (0.98 and 0.76, respectively). In Group 2, UDVA improved to 0.99 and 0.96, respectively. The target refraction was achieved in all cases without loss of BCVA and remained stable throughout the follow-up. The postoperative values of UDVA, BCVA, and spherical equivalent showed no significant change over time. Near visual acuity was evaluated binocularly—preoperatively with maximum distance correction and postoperatively without correction. In Group 1 (monovision), postoperative uncorrected near visual acuity (UNVA) increased to 0.99 – 1.0, whereas in Group 2 it reached only 0.37. Binocular vision was preserved in all patients, and visual field parameters remained within normal limits before and after surgery in all cases. Conclusion. Corneal lenticule extraction using the CLEAR technique with the monovision approach provides high postoperative visual acuity at both distance and near in presbyopic myopic patients while maintaining binocular and peripheral vision.