Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrey S. Agapov has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reactivity of Antibodies Immobilized on Gold Nanoparticles: Fluorescence Quenching Study

    by Dmitriy V. Sotnikov, Andrey S. Agapov, Anatoly V. Zherdev, Boris B. Dzantiev

    Antibodies labeled with gold nanoparticles are widely used in analytical systems. Consequently, the choice of methods for producing such conjugates requires a precise determination of the retained reactivity of the antibodies. Existing methods give highly variable results, necessitating new, simple, and accurate approaches. This study demonstrates how a fluorescein (FL) and anti-FL antibody pair can be used to comparatively evaluate conjugation conditions. The method is based on the quenching of fluorescein emission after binding to antibodies, enabling real-time monitoring of interactions in the reaction medium. Using this approach, we compared a series of conjugates of gold nanoparticles (average diameter 24 nm) and anti-FL antibodies that were obtained with antibody concentrations of 5, 10, and 20 μg/mL during the conjugation. The proportion of antibodies that retained their reactivity varied from 11% to 58%. We also estimated the blocking of the conjugates’ surfaces by two widely used reagents, bovine serum albumin and mercapto polyethylene glycol. It was found that the former provides better retention of antigen-binding activity of immobilized antibodies. The difference between these two kinds of preparations is most pronounced—reaching up to a twofold change—at lower antibody densities.


  • Open Access

    Enhanced Emission of Fluorescein Label in Immune Complexes Provides for Rapid Homogeneous Assay of Aflatoxin B1

    by Dmitriy V. Sotnikov, Andrey S. Agapov, Sergei A. Eremin, Anatoly V. Zherdev, Boris B. Dzantiev

    Homogeneous fluorescence immunoassays are in high demand due to their simplicity, rapidity, sensitivity, and specificity. These methods typically utilize immune-induced changes in the rotational mobility of the fluorophore with depolarization of plane-polarized excitation light (FPIA, etc.) or fluorescence quenching based on intramolecular energy transfer (FRET, etc.). This article presents an immunoassay based on enhanced emission of the fluorescein label in immune complexes. Over the entire history of fluorescence immunoassay research, this effect has been described in a few papers, while it allows overcoming the limitations of prevailing approaches. We discovered the assay for detecting aflatoxin B1 (AFB1), a widespread toxic contaminant of agricultural products. The one-step assay procedure consists of mixing the sample with antibodies and fluorescently labeled AFB1, accompanied by fluorescence measurement. This method enables the detection of AFB1 at concentrations up to 200 pg/mL in 10 min, including measurements in complex samples (corn extracts). Minimal manipulations in the course of the testing also provide high accuracy. The AFB1 revealed in contaminated corn samples was in the range of 76–136%. The influence of immune complex formation on the fluorescent label’s emission can be easily tested and serve as a basis for applying this principle to other diverse analytes and various kinds of samples.