Youssef Ait El Kadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Youssef Ait El Kadi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Abdellah Bouzaid
Engineering and Applied Physics Laboratory (EAPL), Superior School of Technology, Sultan Moulay Slimane University, Beni Mellal 23000, Morocco
1 shared publication - Fatima Zahra Baghli
University Abdelmalek Essaâdi
1 shared publication - Hamza Belkhanchi
Engineering and Applied Physics Laboratory (EAPL), Superior School of Technology, Sultan Moulay Slimane University, Beni Mellal 23000, Morocco
1 shared publication - Mohammed Miri
Engineering and Applied Physics Laboratory (EAPL), Superior School of Technology, Sultan Moulay Slimane University, Beni Mellal 23000, Morocco
1 shared publication - Yassine Lakhal
Laboratory of Engineering and Applied Physics, Higher School of Technology of Beni Mallal, Sultan Moulay University, Beni Mellal 23000, Morocco
1 shared publication - Younes Ziat
Engineering and Applied Physics Laboratory (EAPL), Superior School of Technology, Sultan Moulay Slimane University, Beni Mellal 23000, Morocco
1 shared publication
Latest Publications
- Open Access
First-Principles Investigation of Structural Stability, Mechanical, Electronic, and Thermoelectric Properties of LiYN (Y = Sr, Mg, Zn) Compounds Under Hydrostatic Pressure
This study investigates the pressure-dependent structural, electronic, mechanical, and thermoelectric properties of LiYN (Y = Sr, Mg, Zn) half-Heusler compounds using first-principles calculations. The structural stability was analyzed by fitting the total energy versus volume curves using the Birch–Murnaghan equation of state, allowing the determination of equilibrium lattice parameters and bulk moduli at pressures of 0, 5, and 10 GPa. Elastic constants were calculated to assess the mechanical stability, and all compounds satisfy the Born stability criteria over the entire pressure range. The Pugh ratio (B/G) and Poisson’s ratio (ν) indicate that LiSrN, LiMgN, and LiZnN exhibit predominantly brittle behavior under 0 GPa. Electronic band structure calculations reveal that LiMgN and LiZnN exhibit direct band gaps, whereas LiSrN shows an indirect band gap. Increasing pressure leads to a systematic widening of the band gaps due to lattice compression. Thermoelectric properties were evaluated using the Boltzmann transport theory within the constant relaxation time approximation. The Seebeck coefficient, electrical conductivity, and figure of merit (ZT) were found to be strongly dependent on both temperature and pressure. Notably, at 300 K, the ZT values increase from 0.005, 0.35, and 0.54 at 0 GPa to 0.027, 1.12, and 1.13 at 10 GPa for LiMgN, LiSrN, and LiZnN, respectively. These results demonstrate that hydrostatic pressure significantly enhances the thermoelectric performance of LiYN compounds, highlighting their promising potential for thermoelectric energy conversion applications.
Open AccessFirst-Principles Investigation of Structural Stability, Mechanical, Electronic, and Thermoelectric Properties of LiYN (Y = Sr, Mg, Zn) Compounds Under Hydrostatic Pressure
This study investigates the pressure-dependent structural, electronic, mechanical, and thermoelectric properties of LiYN (Y = Sr, Mg, Zn) half-Heusler compounds using first-principles calculations. The structural stability was analyzed by fitting the total energy versus volume curves using the Birch–Murnaghan equation of state, allowing the determination of equilibrium lattice parameters and bulk moduli at pressures of 0, 5, and 10 GPa. Elastic constants were calculated to assess the mechanical stability, and all compounds satisfy the Born stability criteria over the entire pressure range. The Pugh ratio (B/G) and Poisson’s ratio (ν) indicate that LiSrN, LiMgN, and LiZnN exhibit predominantly brittle behavior under 0 GPa. Electronic band structure calculations reveal that LiMgN and LiZnN exhibit direct band gaps, whereas LiSrN shows an indirect band gap. Increasing pressure leads to a systematic widening of the band gaps due to lattice compression. Thermoelectric properties were evaluated using the Boltzmann transport theory within the constant relaxation time approximation. The Seebeck coefficient, electrical conductivity, and figure of merit (ZT) were found to be strongly dependent on both temperature and pressure. Notably, at 300 K, the ZT values increase from 0.005, 0.35, and 0.54 at 0 GPa to 0.027, 1.12, and 1.13 at 10 GPa for LiMgN, LiSrN, and LiZnN, respectively. These results demonstrate that hydrostatic pressure significantly enhances the thermoelectric performance of LiYN compounds, highlighting their promising potential for thermoelectric energy conversion applications.
- Open Access
- 19 April 2023
- Published by Universitas Muhammadiyah Yogyakarta in Journal of Robotics and Control (JRC)
- Vol. 4 (3) , 289-298
The Efficiency of an Optimized PID Controller Based on Ant Colony Algorithm (ACO-PID) for the Position Control of a Multi-articulated System
In this article, a robot manipulator is controlled by the PID controller in a closed loop system with unit feedback. The difficulty of using the controller is parameter tuning, because the tuning parameters still use the trial and error method to find the PID parameter constants, namely Proportional Gain (Kp), Integral Gain (Ki) and Derivative Gain (Kd). In this case the Ant colony Optimization algorithm (ACO) is used to find the best gain parameters of the PID. The Ant algorithm is a method of combinatorial optimization, which utilizes the pattern of ants search for the shortest path from the nest to the place where the food is located, this concept is applied to tuning PID parameters by minimizing the objective function such that the robot manipulator has improved performance characteristics. This work uses the Matlab Simulink environment, First, after obtaining the system model, the ant colony algorithm is used to determine the proper coefficients 𝐾p, 𝐾i, and Kd in order to minimize the trajectory errors of the two joints of the robot manipulator. Then, the parameters will implement in the robot system. According to the results of the computer simulations, the proposed method (ACO-PID) gives a system that has a good performance compared with the classical PID.
- 19 April 2023
- Published by Universitas Muhammadiyah Yogyakarta in Journal of Robotics and Control (JRC)
- Vol. 4 (3) , 289-298
Open AccessThe Efficiency of an Optimized PID Controller Based on Ant Colony Algorithm (ACO-PID) for the Position Control of a Multi-articulated System
In this article, a robot manipulator is controlled by the PID controller in a closed loop system with unit feedback. The difficulty of using the controller is parameter tuning, because the tuning parameters still use the trial and error method to find the PID parameter constants, namely Proportional Gain (Kp), Integral Gain (Ki) and Derivative Gain (Kd). In this case the Ant colony Optimization algorithm (ACO) is used to find the best gain parameters of the PID. The Ant algorithm is a method of combinatorial optimization, which utilizes the pattern of ants search for the shortest path from the nest to the place where the food is located, this concept is applied to tuning PID parameters by minimizing the objective function such that the robot manipulator has improved performance characteristics. This work uses the Matlab Simulink environment, First, after obtaining the system model, the ant colony algorithm is used to determine the proper coefficients 𝐾p, 𝐾i, and Kd in order to minimize the trajectory errors of the two joints of the robot manipulator. Then, the parameters will implement in the robot system. According to the results of the computer simulations, the proposed method (ACO-PID) gives a system that has a good performance compared with the classical PID.