Mohammad Shaheed
Research Subjects
Mohammad Shaheed has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Achint Juneja
Department of Orthodontics and Dentofacial Orthopedics Institute of Dental Studies and Technologies Modinagar India
1 shared publication - Monis Raza
Department of Orthodontics and Dentofacial Orthopaedics, I.T.S. Center for Dental Studies and Research, Muradnagar, Ghaziabad, Uttar Pradesh, India
1 shared publication - Nivedita Sharma1 shared publication
- Prachi Mehra1 shared publication
- Stuti Mohan
Swami Vivekanand Subharti University Subharti, India
1 shared publication
Latest Publications
- 18 December 2025
- Published by AMALTEA Medical Publishing House in Romanian Journal of Stomatology
- Vol. 71 (4) , 448
Comparative evaluation of the rate of space closure using silver nano-coated wires in metal and ceramic brackets - a split mouth randomized controlled study
Background. Friction at the bracket–archwire interface reduces the efficiency of sliding mechanics during space closure. Silver nanoparticle (AgNP) coating may reduce friction and accelerate tooth movement. Objective. To compare the rate of space closure using AgNP-coated versus non-coated stainless steel archwires in metal and ceramic bracket systems. Methods. A split-mouth randomized controlled trial was conducted on 20 patients (aged 18–25 years) undergoing fixed orthodontic treatment with bilateral first premolar extractions. Stainless steel 0.019 × 0.025-inch archwires were half-coated with AgNPs using PVD–DC magnetron sputtering. In each patient, coated and non-coated segments were randomly allocated to contralateral quadrants with MBT metal or ceramic brackets. NiTi closed-coil springs (150 g) were used for retraction. Space closure was measured from baseline (T0) and at monthly intervals for 3 months (T1, T2, T3) on dental casts. Results. Over 3 months, coated wires demonstrated significantly greater space closure than non-coated wires in the metal bracket group (maxilla: 3.21 ± 0.12 mm vs. 2.61 ± 0.14 mm; mandible: 2.61 ± 0.15 mm vs. 2.02 ± 0.13 mm; both p < 0.001). Monthly closure was consistently higher with coated wires (maxilla: 1.05-1.08 mm/month vs. 0.86-0.89 mm/month; mandible: 0.87 mm/month vs. 0.66-0.69 mm/month). No significant differences were observed in ceramic brackets across the 3-month period (p > 0.05). The maxillary arch showed faster closure than the mandible irrespective of wire coating (p < 0.001). Conclusions. Silver nanoparticle coating significantly enhanced the rate of orthodontic space closure when used with metal brackets but showed no benefit with ceramic brackets. AgNP-coated archwires may offer a clinically relevant reduction in treatment duration in metal systems. Larger, longer-duration trials are recommended to confirm durability and clinical applicability.
- 18 December 2025
- Published by AMALTEA Medical Publishing House in Romanian Journal of Stomatology
- Vol. 71 (4) , 448
Comparative evaluation of the rate of space closure using silver nano-coated wires in metal and ceramic brackets - a split mouth randomized controlled study
Background. Friction at the bracket–archwire interface reduces the efficiency of sliding mechanics during space closure. Silver nanoparticle (AgNP) coating may reduce friction and accelerate tooth movement. Objective. To compare the rate of space closure using AgNP-coated versus non-coated stainless steel archwires in metal and ceramic bracket systems. Methods. A split-mouth randomized controlled trial was conducted on 20 patients (aged 18–25 years) undergoing fixed orthodontic treatment with bilateral first premolar extractions. Stainless steel 0.019 × 0.025-inch archwires were half-coated with AgNPs using PVD–DC magnetron sputtering. In each patient, coated and non-coated segments were randomly allocated to contralateral quadrants with MBT metal or ceramic brackets. NiTi closed-coil springs (150 g) were used for retraction. Space closure was measured from baseline (T0) and at monthly intervals for 3 months (T1, T2, T3) on dental casts. Results. Over 3 months, coated wires demonstrated significantly greater space closure than non-coated wires in the metal bracket group (maxilla: 3.21 ± 0.12 mm vs. 2.61 ± 0.14 mm; mandible: 2.61 ± 0.15 mm vs. 2.02 ± 0.13 mm; both p < 0.001). Monthly closure was consistently higher with coated wires (maxilla: 1.05-1.08 mm/month vs. 0.86-0.89 mm/month; mandible: 0.87 mm/month vs. 0.66-0.69 mm/month). No significant differences were observed in ceramic brackets across the 3-month period (p > 0.05). The maxillary arch showed faster closure than the mandible irrespective of wire coating (p < 0.001). Conclusions. Silver nanoparticle coating significantly enhanced the rate of orthodontic space closure when used with metal brackets but showed no benefit with ceramic brackets. AgNP-coated archwires may offer a clinically relevant reduction in treatment duration in metal systems. Larger, longer-duration trials are recommended to confirm durability and clinical applicability.