Sena Bekerecioğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sena Bekerecioğlu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bahar Bankoğlu Yola
Department of Engineering Basic Sciences, Faculty of Engineering and Natural Sciences, Gaziantep Islam Science and Technology University, Gaziantep 27260, Türkiye
2 shared publications - İlknur Polat
Department of Nutrition and Dietetics, Faculty of Health Sciences, Hasan Kalyoncu University, Gaziantep 27010, Türkiye
2 shared publications - Mehmet Lütfi Yola
Department of Biology, Faculty of Science, Ankara University, Ankara 06100, Türkiye
2 shared publications - Necip Atar
Department of Chemical Engineering, Faculty of Engineering, Pamukkale University, Denizli 20160, Turkey
2 shared publications - Adem Sarı
Department of Public Health Services, Provincial Health Directorate, Gaziantep, Türkiye
1 shared publication - Ebru Annaç
Department of Public Health Services, Provincial Health Directorate, Gaziantep, Türkiye
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by The European Research Journal in The European Research Journal
- p. 1114-1126
Association of Meal and Physical Activity Habits with Body Composition and Obesity Indicators in Gaziantep Provincial Health Directorate Personnel: A Cross-Sectional Study
Objective: The aim of this study was to examine the associations between meal habits, regular physical activity, obesity, and detailed body composition indicators among personnel working at the Gaziantep Provincial Health Directorate headquarters. Methods: This cross-sectional study was conducted between December 2025 and January 2026. A total of 200 personnel aged 18 years and older with complete data were included in the final analysis. Data were collected via face-to-face interviews covering sociodemographic characteristics, meal habits, and physical activity status. Body composition was assessed using two complementary approaches: anthropometric measurements (height, BMI, waist, hip, and neck circumference) and bioelectrical impedance analysis (BIA), the latter providing fat, muscle, lean mass, body water, and visceral fat estimates. Results: The mean (SD) age of participants was 37.71 (7.96) years, and the mean (SD) BMI was 26.05 (4.09) kg/m². In total, 57.5% of participants were overweight or obese. Individuals who skipped at least one main meal had significantly higher BMI, body fat percentage, and visceral fat scores, as well as significantly lower muscle and body water percentages (P < .05). Snack consumption was associated with lower muscle and lean mass percentages, whereas regular physical activity was associated with a more favorable body composition profile (P < .05). Several correlations between meal-frequency variables and body composition parameters were statistically significant but weak in magnitude. Conclusion: This study demonstrates that meal skipping and insufficient physical activity are associated with an unfavorable body composition profile, whereas regular physical activity is associated with a more favorable body composition. The findings underscore the importance of workplace-based interventions promoting healthy dietary habits and physical activity among public sector employees.
- 1 October 2026
- Published by The European Research Journal in The European Research Journal
- p. 1114-1126
Open AccessAssociation of Meal and Physical Activity Habits with Body Composition and Obesity Indicators in Gaziantep Provincial Health Directorate Personnel: A Cross-Sectional Study
Objective: The aim of this study was to examine the associations between meal habits, regular physical activity, obesity, and detailed body composition indicators among personnel working at the Gaziantep Provincial Health Directorate headquarters. Methods: This cross-sectional study was conducted between December 2025 and January 2026. A total of 200 personnel aged 18 years and older with complete data were included in the final analysis. Data were collected via face-to-face interviews covering sociodemographic characteristics, meal habits, and physical activity status. Body composition was assessed using two complementary approaches: anthropometric measurements (height, BMI, waist, hip, and neck circumference) and bioelectrical impedance analysis (BIA), the latter providing fat, muscle, lean mass, body water, and visceral fat estimates. Results: The mean (SD) age of participants was 37.71 (7.96) years, and the mean (SD) BMI was 26.05 (4.09) kg/m². In total, 57.5% of participants were overweight or obese. Individuals who skipped at least one main meal had significantly higher BMI, body fat percentage, and visceral fat scores, as well as significantly lower muscle and body water percentages (P < .05). Snack consumption was associated with lower muscle and lean mass percentages, whereas regular physical activity was associated with a more favorable body composition profile (P < .05). Several correlations between meal-frequency variables and body composition parameters were statistically significant but weak in magnitude. Conclusion: This study demonstrates that meal skipping and insufficient physical activity are associated with an unfavorable body composition profile, whereas regular physical activity is associated with a more favorable body composition. The findings underscore the importance of workplace-based interventions promoting healthy dietary habits and physical activity among public sector employees.
- Open Access
Molecularly Imprinted Deoxynivalenol Surface Plasmon Resonance Sensor Based on Sulfur-Doped Boron Graphitic Carbon Nitride
Deoxynivalenol (DEOX), a dangerous mycotoxin, causes serious health problems for humans and animals. Hence, the on-site monitoring of DEOX has begun to be important in the health and food sectors in recent years. In the present study, a molecularly imprinted surface plasmon resonance (SPR) sensor based on sulfur-doped boron graphitic carbon nitride (S-B-g-C3N4) was developed and applied for detecting DEOX in drinking water and orange juice samples, achieving high recovery. After the S-B-g-C3N4 nanocomposite was synthesized via thermal polycondensation and microwave treatment with a highly environmentally friendly approach, a SPR chip was modified with the S-B-g-C3N4 nanocomposite considering the high affinity between gold and sulfur. Then, the molecularly imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite was prepared in the presence of methacryloylamidoglutamic acid (MAGA) as the monomer and N,N′-azobisisobutyronitrile (AIBN) as the initiator. The DEOX-imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite showed linearity from 1.0 to 10.0 ng L−1, with a limit of quantification (LOQ) of 1.0 ng L−1 and a limit of detection (LOD) of 0.30 ng L−1. Finally, the selectivity, repeatability, and reproducibility of the DEOX-imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite were investigated.
Open AccessMolecularly Imprinted Deoxynivalenol Surface Plasmon Resonance Sensor Based on Sulfur-Doped Boron Graphitic Carbon Nitride
Deoxynivalenol (DEOX), a dangerous mycotoxin, causes serious health problems for humans and animals. Hence, the on-site monitoring of DEOX has begun to be important in the health and food sectors in recent years. In the present study, a molecularly imprinted surface plasmon resonance (SPR) sensor based on sulfur-doped boron graphitic carbon nitride (S-B-g-C3N4) was developed and applied for detecting DEOX in drinking water and orange juice samples, achieving high recovery. After the S-B-g-C3N4 nanocomposite was synthesized via thermal polycondensation and microwave treatment with a highly environmentally friendly approach, a SPR chip was modified with the S-B-g-C3N4 nanocomposite considering the high affinity between gold and sulfur. Then, the molecularly imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite was prepared in the presence of methacryloylamidoglutamic acid (MAGA) as the monomer and N,N′-azobisisobutyronitrile (AIBN) as the initiator. The DEOX-imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite showed linearity from 1.0 to 10.0 ng L−1, with a limit of quantification (LOQ) of 1.0 ng L−1 and a limit of detection (LOD) of 0.30 ng L−1. Finally, the selectivity, repeatability, and reproducibility of the DEOX-imprinted SPR sensor based on the S-B-g-C3N4 nanocomposite were investigated.
- Open Access
Molecularly Imprinted Electrochemical Sensor Based on Palladium@Yttrium Oxide@Boronnitride Nanocomposite for Determination of Glyphosate Herbicide in Drinking Water Samples
Glyphosate (GLY) is a systemic herbicide used in agriculture and has a carcinogenic effect after long-term usage. Herein, a molecularly imprinted electrochemical sensor based on palladium@yttrium oxide@boron nitride nanosheets (Pd/Y2O3@BN) nanocomposite was developed for the detection of GLY in drinking water. After the preparation of Pd/Y2O3@BN nanocomposite by using sonication and NaBH4 reduction methods, Pd/Y2O3@BN nanocomposite as electrode material was applied on glassy carbon electrode by infrared lamp. Then, a molecularly imprinted glassy carbon electrode based on Pd/Y2O3@BN (MIP) was designed with cyclic voltammetry (CV) in presence of pyrrole monomer and GLY molecule. After the spectroscopic and microscopic characterizations, the linearity in the range of 1.0 × 10−9–1.0 × 10−8 M with a detection limit (LOD) of 3.3 × 10−10 M was obtained for GLY molecule. After MIP electrode was applied to drinking water samples with high recovery, the selectivity, stability, repeatability, and reproducibility features were studied. These promising results suggested that the as-fabricated MIP electrode presented a novel and highly effective approach for GLY assay.
Open AccessMolecularly Imprinted Electrochemical Sensor Based on Palladium@Yttrium Oxide@Boronnitride Nanocomposite for Determination of Glyphosate Herbicide in Drinking Water Samples
Glyphosate (GLY) is a systemic herbicide used in agriculture and has a carcinogenic effect after long-term usage. Herein, a molecularly imprinted electrochemical sensor based on palladium@yttrium oxide@boron nitride nanosheets (Pd/Y2O3@BN) nanocomposite was developed for the detection of GLY in drinking water. After the preparation of Pd/Y2O3@BN nanocomposite by using sonication and NaBH4 reduction methods, Pd/Y2O3@BN nanocomposite as electrode material was applied on glassy carbon electrode by infrared lamp. Then, a molecularly imprinted glassy carbon electrode based on Pd/Y2O3@BN (MIP) was designed with cyclic voltammetry (CV) in presence of pyrrole monomer and GLY molecule. After the spectroscopic and microscopic characterizations, the linearity in the range of 1.0 × 10−9–1.0 × 10−8 M with a detection limit (LOD) of 3.3 × 10−10 M was obtained for GLY molecule. After MIP electrode was applied to drinking water samples with high recovery, the selectivity, stability, repeatability, and reproducibility features were studied. These promising results suggested that the as-fabricated MIP electrode presented a novel and highly effective approach for GLY assay.