AAAmir Hossein Ayyoubi

Amir Hossein Ayyoubi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amir Hossein Ayyoubi has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A translational platform for brain-computer interfaces and adaptive neuromodulation: Technical characterization, long-term validation, and implementation of the CorTec brain interchange-BCI2000 ecosystem

    by Frederik Lampert, Matthew R Baker, Filip Mivalt, William Engelhardt, Nicholas Luczak, C. Alexis Gkogkidis, Martin Schuettler, Amir Hossein Ayyoubi, Behrang Fazli Besheli, Max Alexander van Den Boom, et al.

    Objective: Adaptive neuromodulation systems and implantable brain-computer interfaces (BCIs) are promising therapies for neurological and psychiatric disorders. However, their broader translation into research and clinical practice remains limited by technological complexity, restricted access to implantable research platforms, and the lack of standardized, reproducible experimental workflows. We therefore aimed to develop and validate an open, general-purpose translational ecosystem that enables rapid development, evaluation, and dissemination of novel neuromodulation and implantable BCI paradigms. Approach: The CorTec Brain Interchange (BIC) implantable neural sensing and stimulation device was integrated with the open-source BCI2000 platform to create a modular, extensible neuromodulation ecosystem. We established a standardized battery of quantitative assessments to characterize implantable neuromodulation systems to comprehensively evaluate the CorTec BIC device through benchtop characterization, long-term preclinical in vivo validation, and a human feasibility demonstration using the benchtop BIC system connected to externalized leads. Results: Comprehensive benchtop characterization of the BIC device independently validated previously reported performance while extending its evaluation through quantification of recording noise, acquisition and stimulation latencies, and validation of impedance measurements. Long-term in vivo validation in five canines, with the longest implantation exceeding three years, demonstrated stable chronic recordings while also capturing progressive deterioration of individual channels through longitudinal changes in signal quality and impedance. The ecosystem enabled active functional decoding more than two years after implantation, closed-loop stimulation using arbitrary spectral biomarkers, capturing brain stimulation evoked potentials, detection of epilepsy-associated biomarkers and observational assessment of their response to stimulation. In addition, we translated an established one-dimensional BCI cursor-control paradigm to the BIC benchtop system, demonstrating ecosystem portability and feasibility with a human participant. Finally, we share surgical protocols, imaging and analysis pipelines, datasets, and software to facilitate reproducible neuromodulation research. Significance: We present a versatile, open-source translational ecosystem that supports a wide range of neuromodulation and implantable BCI applications with minimal modification. By combining comprehensive hardware characterization with standardized software tools and experimental workflows, this work provides a practical reference for researchers adopting the BIC platform while establishing a broadly applicable framework for systematic characterization of implantable neuromodulation systems. The ecosystem lowers technical barriers to implantable neurotechnology research, promotes reproducibility, and provides a foundation for accelerating the development and clinical translation of next-generation adaptive neuromodulation and implantable BCI therapies for patients with neurological and psychiatric disorders.

  • Open Access

    Moving beyond spike detection: High frequency‐driven masking improves seizure onset zone localization in intracranial electroencephalography

    by Amir Hossein Ayyoubi, Behrang Fazli Besheli, Valentina Hrtonova, Jhan Luke Okkabaz, Chandra Prakash Swamy, Zhiyi Sha, Jay Gavvala, Nicholas Gregg, Thomas R. Henry, Sandipan Pati, et al.

    Objective: Interictal epileptiform spikes (IESs) are widely used biomarkers of epileptogenic tissue in presurgical epilepsy evaluation. However, their reliability for seizure onset zone (SOZ) localization in high‐density intracranial electroencephalography (iEEG) remains inconsistent. It is underexplored whether this variability reflects methodological differences across detection algorithms or a limitation of IESs as a biomarker. This study evaluates whether IES detection alone provides sufficient spatial specificity for accurate SOZ localization in iEEG. Methods: We systematically benchmarked eight established IES detection algorithms using iEEG recordings from 35 patients with drug‐resistant focal epilepsy. To provide a clinically meaningful reference, algorithm performance was evaluated against the clinically defined SOZ. To refine detection outputs and move beyond only IES detection, we applied masking strategies to isolate informative IES subsets based on rate, amplitude, frequency, and co‐occurrence with high‐frequency oscillations (HFOs). Conceptually, masking acts as a spatial refinement strategy that progressively restricts diffuse IES activity to more focal, pathologically relevant event populations. Results: Despite substantial variability in detection characteristics, SOZ localization performance (ratio of events originating from SOZ divided by total number of events) converged within a narrow range (.23–.51), suggesting that IESs exhibit an intrinsic ceiling in SOZ localization performance when used alone. Amplitude‐based masking yielded modest improvements, whereas frequency‐based masking reduced performance. In contrast, IES‐HFO co‐occurrence markedly improved localization, particularly when combined with rate‐based masking, achieving a median SOZ localization ratio of .89, exceeding IESs (.37) and HFOs (.63) evaluated independently. Significance: These findings demonstrate that IES‐based SOZ localization may require moving beyond detection‐only approaches. The integration of informed, biomarker‐driven masking strategies provides a more robust framework for identifying the activity most relevant to the epileptogenic network and paves the way for future incorporation into the clinical decision‐making pipeline.

  • Open Access

    Adaptive neuromodulation dialogues: navigating current challenges and emerging innovations in neuromodulation system development

    by Frederik Lampert, Matthew R Baker, Michael A Jensen, Amir H Ayyoubi, Christian Bentler, Jessica L Bowersock, Rosana Esteller, Jeffrey A Herron, Graham W Johnson, Daryl R Kipke, et al.

    Adaptive neuromodulation systems and implantable brain-computer interfaces have made notable strides in recent years, translating experimental prototypes into clinical applications and garnering substantial attention from the public. This surge in interest is accompanied by increased scrutiny related to the safety, efficacy, and ethical implications of these systems, all of which must be directly addressed as we introduce new neurotechnologies. In response, we have synthesized the insights resulting from discussions between groups of experts in the field and summarized them into five key domains essential to therapeutic device development: (1) analyzing current landscape of neuromodulation devices and translational platforms (2) identifying clinical need, (3) understanding neural mechanisms, (4) designing viable technologies, and (5) addressing ethical concerns. The role of translational research platforms that allow rapid, iterative testing of hypotheses in both preclinical and clinical settings is emphasized. These platforms must balance experimental flexibility with patient safety and clear clinical benefit. Furthermore, requirements for interoperability, modularity, and wireless communication protocols are explored to support long-term usability and scalability. The current regulatory processes and funding models are examined alongside the ethical responsibilities of researchers and device manufacturers. Special attention is given to the role of patients as active contributors to research and to the long-term obligations we have to them as the primary burden-bearers of the implanted neurotechnologies. This article represents a synthesis of scientific, engineering, and clinical viewpoints to inform key stakeholders in the neuromodulation and brain-computer interface spaces.