MIMuhammed Awwal Imran

Muhammed Awwal Imran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Muhammed Awwal Imran has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigating the Influence of Banana Leaf Ash on the Compressive Strength and Chloride Resistance of Concrete

    by Akinfenwa Aanu, Muhammed Awwal Imran, Jamiu Lateef

    The high compressive strength, durability, fire resistance, and formability of concrete have made its use widespread in the construction industry. However, the production challenges and limitations (e.g., emission of large quantities of CO₂, labour intensity, etc.) of Portland cement, a major aggregate of concrete, have raised the need for a sustainable and viable alternative. Therefore, this study investigated the effect of partial replacement of OPC with Banana Leaf Ash (BLA) on compressive strength and chloride resistance of concrete. BLA has properties known as pozzolanic properties. This property is potentially beneficial for cement replacement. To carry out the investigation, concrete mixes were prepared with 0%, 10%, and 20% BLA replacement by weight of cement, maintaining a water-cement ratio of 0.5. Cube specimens were cast and cured in water (control) and solutions containing 1% and 2.5% calcium chloride (CaCl₂) for 28, 42, and 60 days. Compressive strength tests were conducted, which revealed that while strength generally increased with curing age in water, the 10% BLA replacement yielded the highest compressive strength compared to the control and 20% replacement across all curing media and ages. Concrete with 10% BLA demonstrated superior resistance to chloride attack, showing less strength degradation compared to the control and 20% BLA specimens in the 1% and 2.5% CaCl₂ solutions, and the optimal replacement level appears to be around 10%, at which point concrete’s durability in chloride-rich environments was effectively enhanced.

  • Open Access

    Performance Evaluation of Natural Lighting in University Student Residence in Nigeria

    by Imran A. Muhammed, Jamiu Lateef

    Natural lighting in residential buildings, especially student hostels, plays a critical role in promoting energy efficiency, visual comfort, and environmental sustainability. This study evaluates the performance of daylighting in selected private hostels in Ile-Ife, Nigeria, through an integrated methodological framework combining objective lux measurements, subjective perception surveys, and ethnographic observations of bioclimatic design features. Indoor and outdoor illuminance were recorded during daylight hours using a calibrated light meter, and daylight factors were computed in reference to CIBSE LG10 guidelines. Questionnaire data from 200 respondents were analysed using ANOVA and t-tests to explore student behaviours and satisfaction with lighting conditions. Observations revealed the prevalence of passive design features such as courtyards, large windows, and shading devices. The findings reveal a prevalent condition of poor daylighting performance, with DF values typically ranging from 0.0008% to 2.05%, significantly below internationally recommended minimums for conducive living and study environments. Despite these objective shortcomings, subjective occupant satisfaction exhibited variability, with a notable portion expressing contentment. Many students (43.0%) utilize their hostel rooms as primary study locations, frequently necessitating artificial light supplementation. Observed passive design strategies included internal courtyards, screening elements, shading provisions, fenestration characteristics, balconies, circulation corridors, and pre-paid energy metering systems. The study concludes a substantial dependence on artificial lighting, driven by inadequate natural illumination design, and recommends targeted education and enforcement of building design regulations prioritizing daylight access to enhance energy conservation, visual comfort, and overall occupant well-being.