SSSuzette E. Sutherland

Suzette E. Sutherland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suzette E. Sutherland has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-Year Efficacy and Safety of Revi Implantable Tibial Neuromodulation from the Pivotal OASIS Study

    by Cindy L. Amundsen, Suzette E. Sutherland, John P. F. A. Heesakkers, Philip Toozs-Hobson, Frank Martens, Rebecca J. McCrery, Kevin Benson, Kevin J. Cline, Peter R. Rodine, Roger R. Dmochowski

    Revi® is a novel implantable tibial neuromodulation (iTNM) system powered by an external, battery-operated wearable that facilitates individually tailored stimulation to provide treatment for urgency urinary incontinence (UUI). The Revi System (manufactured by BlueWind Medical) is the first FDA-cleared implantable neuromodulation device that can be used in traditionally non-refractory patients. Three-year follow-up results from the pivotal FDA-approval trial, the OASIS Study, are presented. The Revi System was implanted in 151 women. The primary efficacy and safety endpoints were assessed at 6 and 12 months, respectively; thereafter, participants were consented to extend follow-up to 3 years for assessments of long-term treatment durability and safety. Ninety-three percent (140/151) completed the 12-month study and 85% (119/140) met screening criteria and consented to the 36-month extension study. Ninety participants (76%, (90/119) completed the 36-month assessment and 79% (71/90) were therapy responders (≥ 50% reduction in UUI episodes, demonstrated on a 3-day voiding diary). Sustained therapeutic responses were reported, with durable effectiveness between 6 and 36 months (response rates of 78% and 79%, respectively).Notably, 95% (83/87) reported therapeutic satisfaction and 82% (74/90) reported feeling "much better" or "very much better" based on the Patient Global Impression of Improvement (PGI-I) scale. No device- or procedure- related serious adverse events were reported through 36 months. In women with UUI, Revi - an iTNM system powered by a patient-controlled, external wearable ankle device - showed meaningful and durable efficacy, high patient satisfaction, and an excellent safety profile through 3 years.


  • Open Access

    Impact of Revi® Implantable Tibial Neuromodulation on Quality of Life in Patients with Urgency Urinary Incontinence

    by Suzette E. Sutherland, John P. F. A. Heesakkers, Kimberly L. Ferrante, Roger R. Dmochowski

    Introduction and Hypothesis The objective was to evaluate quality-of-life (QoL) improvements following Revi® implantable tibial neuromodulation (ITNM) in patients with urgency urinary incontinence (UUI). Methods This prospective, multicenter study evaluated the Revi® System, an ITNM device that allows for at-home therapy using an external, battery-operated unit. The primary efficacy and safety endpoints were assessed at 6 and 12 months; thereafter, participants either exited the study or consented to extend follow-up. This completers analysis evaluated QoL outcomes using the Overactive Bladder Questionnaire (OAB-q) and the total transformed Health-Related QoL (HRQL) score through 24 months. Results Subfascial implantation of the Revi System was performed in 151 participants. Primary efficacy and safety endpoints were met and no device- or procedure-related serious adverse events occurred. Consistent QoL benefits were seen throughout 24 months, with clinically significant (≥ 10-point change) and sustainable improvements in symptom severity in all domains of the OAB-q and HRQL scores. Additionally, 96.8% reported treatment benefit, 96.7% reported satisfaction, and 100% reported a willingness to continue therapy at 24 months. Notably, among participants who did not meet the primary efficacy endpoint at 24 months (n = 20; 20.6%), appreciable therapeutic benefit was still noted; 83.3% reported treatment benefit, 66.7% reported satisfaction, and 100% reported a willingness to continue this therapy. Conclusions Revi is an effective and safe intervention for UUI. Two-year results of the Revi System demonstrate clinically meaningful and sustainable improvements to bladder-related and overall health-related QoL, including those whose objective benefit did not meet the primary efficacy endpoint.


  • Open Access

    Two-Year Efficacy and Safety Outcomes of the Pivotal OASIS Study Using the Revi System for Treatment of Urgency Urinary Incontinence

    by John P. F. A. Heesakkers, Philip Toozs-Hobson, Suzette E. Sutherland, Alex Digesu, Cindy L. Amundsen, Rebecca J. McCrery, Stefan De Wachter, Emily R. Kean, Frank Martens, Kevin Benson, et al.

    The BlueWind Medical Device, Revi®, is a novel implantable tibial neuromodulation system powered by an external, battery-operated wearable that facilitates individually tailored stimulation to provide treatment for urgency urinary incontinence (i.e., overactive bladder wet). The Revi System is the first FDA-cleared implantable neuromodulation device which can be used without prior failure with more conservative treatment options. Two-year follow-up results of the OASIS Study are presented. The Revi System was implanted in 151 female participants. The primary efficacy and safety endpoints were assessed at 6- and 12-months, after which participants either consented to extend follow-up for long-term assessment of treatment durability and safety, or they chose to exit the study. Ninety-seven participants completed the 24-month assessment, and of these, 79% were therapy responders (≥ 50% reduction in urgency urinary incontinence episodes (UUIE), demonstrated on a 3-day voiding diary). Importantly, therapeutic response was durable, with comparable effectiveness at 6-, 12-, and 24-months (response rates of 78%, 82%, and 79%, respectively). Participants that completed both the 6- and 24-month assessment had similar demographics and treatment results at the 6-month visit, indicating that these results at 24-months are representative of the overall study population.In addition, high satisfaction and patient impression of improvement were reported, with 97% (88/91) of the participants satisfied with the therapy and 80% (78/97) feeling "much better" or "very much better". There were no serious adverse events related to the device or the procedure through 24 months. Two-year results demonstrate durable efficacy, high patient satisfaction, and a very favorable safety profile.