Wei Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Shen has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Bin Shi
School of Civil Engineering Shenyang Jianzhu University Shenyang People's Republic of China
1 shared publicationShuwei Ju
School of Design and Art Shenyang Jianzhu University Shenyang People's Republic of China
1 shared publicationXin Chen
School of Civil Engineering Shenyang Jianzhu University Shenyang People's Republic of China
1 shared publication
Latest Publications
- 16 December 2025
- Published by Wiley in Structural Concrete
Influence of a thickened insulation material on the flexural performance of a precast concrete sandwich insulation panel connected by steel wire mesh
This study investigates the flexural behavior of precast concrete sandwich panels (PCSPs) utilizing steel wire mesh connectors (SWMCs) through combined experimental and numerical analyses. The research specifically examines the influence of expanded polystyrene (EPS) insulation thickness and the spacing/pitch configuration of oblique steel wires in SWMCs. Key findings demonstrate that increased EPS insulation thickness significantly enhances load‐bearing capacity: when the EPS thickness was increased from 50 to 120 mm and 200 mm, the ultimate flexural capacity improved by 76% and 190%, respectively. Conversely, larger connector spacing and pitch adversely affected structural performance—increasing the wire spacing from 50 to 200 mm reduced flexural capacity by 69.4%, while increasing the pitch from 100 to 400 mm resulted in a 66.3% reduction. The paper further analyzes the underlying working mechanisms and proposes practical design recommendations for engineering applications.
- 16 December 2025
- Published by Wiley in Structural Concrete
Influence of a thickened insulation material on the flexural performance of a precast concrete sandwich insulation panel connected by steel wire mesh
This study investigates the flexural behavior of precast concrete sandwich panels (PCSPs) utilizing steel wire mesh connectors (SWMCs) through combined experimental and numerical analyses. The research specifically examines the influence of expanded polystyrene (EPS) insulation thickness and the spacing/pitch configuration of oblique steel wires in SWMCs. Key findings demonstrate that increased EPS insulation thickness significantly enhances load‐bearing capacity: when the EPS thickness was increased from 50 to 120 mm and 200 mm, the ultimate flexural capacity improved by 76% and 190%, respectively. Conversely, larger connector spacing and pitch adversely affected structural performance—increasing the wire spacing from 50 to 200 mm reduced flexural capacity by 69.4%, while increasing the pitch from 100 to 400 mm resulted in a 66.3% reduction. The paper further analyzes the underlying working mechanisms and proposes practical design recommendations for engineering applications.