Zhenzu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenzu Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Qiao Zhang
Southwest Jiaotong University
2 shared publications - Zhigang Liu
Southwest Jiaotong University
2 shared publications - Bing Lu
Southwest Jiaotong University
1 shared publication - Fang Liu
State Grid Sichuan Economic Research Institute, Chengdu 610095, China
1 shared publication - Haonan Yang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610097, China
1 shared publication - Jian Zeng
State Grid Sichuan Economic Research Institute, Chengdu 610041, China
1 shared publication
Latest Publications
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3679-3689
Flexible Operation for Wayside Hybrid Energy Storage System in Electrified Railway: A Variable-Timebox Model Based on Temporal Clustering Method
In electrified railways, the train generates substantial regenerative braking energy (RBE) during braking mode. Deploying wayside hybrid energy storage systems (HESSs) offers a promising solution for recovering and reusing this energy. However, due to the highly fluctuating nature of train power, existing methods based on fixed timescales often struggle to achieve an effective tradeoff between computational efficiency and modeling accuracy. To resolve these limitations, this article proposes a novel operation approach for HESS based on a variable-timebox model. First, a variable-timebox model is constructed, in which the charging and discharging durations of HESS are treated as decision variables. The model simultaneously optimizes RBE recovery and battery capacity degradation by considering the depth of discharge (DoD). Second, to determine the reasonable duration range, a temporal clustering method is proposed. A change point detection (CPD) strategy based on an improved cumulative sum (CUSUM) algorithm is employed to identify characteristics of the traction load. Finally, the effectiveness of the proposed method is validated using real-world data. The simulation results demonstrate that the proposed method reduces computation time by more than 60% while maintaining modeling accuracy.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3679-3689
Flexible Operation for Wayside Hybrid Energy Storage System in Electrified Railway: A Variable-Timebox Model Based on Temporal Clustering Method
In electrified railways, the train generates substantial regenerative braking energy (RBE) during braking mode. Deploying wayside hybrid energy storage systems (HESSs) offers a promising solution for recovering and reusing this energy. However, due to the highly fluctuating nature of train power, existing methods based on fixed timescales often struggle to achieve an effective tradeoff between computational efficiency and modeling accuracy. To resolve these limitations, this article proposes a novel operation approach for HESS based on a variable-timebox model. First, a variable-timebox model is constructed, in which the charging and discharging durations of HESS are treated as decision variables. The model simultaneously optimizes RBE recovery and battery capacity degradation by considering the depth of discharge (DoD). Second, to determine the reasonable duration range, a temporal clustering method is proposed. A change point detection (CPD) strategy based on an improved cumulative sum (CUSUM) algorithm is employed to identify characteristics of the traction load. Finally, the effectiveness of the proposed method is validated using real-world data. The simulation results demonstrate that the proposed method reduces computation time by more than 60% while maintaining modeling accuracy.
- Open Access
A Method for Energy Storage Capacity Configuration in the Power Grid Along Mountainous Railway Based on Chance-Constrained Optimization
To address the challenges of weak power-grid infrastructure, insufficient power supply capacity along mountainous railways, and severe three-phase imbalance caused by imbalanced traction loads at the point of common coupling (PCC), this paper proposes an energy storage configuration method for mountainous railway power grids considering renewable energy integration. First, a distributionally robust chance-constrained energy storage system configuration model is established, with the capacity and rated power of the energy storage system as decision variables, and the investment costs, operational costs, and grid operation costs as the objective function. Subsequently, by linearizing the three-phase AC power flow equations and transforming the model into a directly solvable linear form using conditional value-at-risk (CVaR) theory, the original configuration problem is converted into a mixed-integer linear programming (MILP) formulation. Finally, simulations based on an actual high-altitude mountainous railway power grid validate the economic efficiency and effectiveness of the proposed model. Results demonstrate that energy storage deployment reduces overall system voltage deviation by 40.7% and improves three-phase voltage magnitude imbalance by 16%.
Open AccessA Method for Energy Storage Capacity Configuration in the Power Grid Along Mountainous Railway Based on Chance-Constrained Optimization
To address the challenges of weak power-grid infrastructure, insufficient power supply capacity along mountainous railways, and severe three-phase imbalance caused by imbalanced traction loads at the point of common coupling (PCC), this paper proposes an energy storage configuration method for mountainous railway power grids considering renewable energy integration. First, a distributionally robust chance-constrained energy storage system configuration model is established, with the capacity and rated power of the energy storage system as decision variables, and the investment costs, operational costs, and grid operation costs as the objective function. Subsequently, by linearizing the three-phase AC power flow equations and transforming the model into a directly solvable linear form using conditional value-at-risk (CVaR) theory, the original configuration problem is converted into a mixed-integer linear programming (MILP) formulation. Finally, simulations based on an actual high-altitude mountainous railway power grid validate the economic efficiency and effectiveness of the proposed model. Results demonstrate that energy storage deployment reduces overall system voltage deviation by 40.7% and improves three-phase voltage magnitude imbalance by 16%.