YLYennybeth Leiva

Yennybeth Leiva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yennybeth Leiva has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel Conei

    Departamento de Procesos Terapéuticos, Facultad de Ciencias de la Salud, Universidad Católica de Temuco, Temuco 4780000, Chile

    2 shared publications
  • Dona Benadof

    Hospital Roberto del Rio, Santiago 8380457, Chile

    1 shared publication
  • Dona Benadof

    Laboratorio clínico, hospital Roberto del Rio;Departamento de pediatría y cirugía, Facultad de Medicina. Universidad de Chile;Centro investigación clínica y asistencial. Facultad de Medicina. Universidad de Chile, Chile

    1 shared publication
  • Mirta Acuña

    Hospital Roberto del Rio, Santiago 8380457, Chile

    1 shared publication
  • Mirta Acuña

    Unidad de infectología, hospital Roberto del Rio;Departamento de pediatría y cirugía, Facultad de Medicina. Universidad de Chile;Centro investigación clínica y asistencial. Facultad de Medicina. Universidad de Chile, Chile

    1 shared publication

Latest Publications

  • Open Access

    Evaluating the Clinical Impact of BioFire Spotfire R/ST on the Management of Pediatric Respiratory Presentations in the Emergency Department: A Pre–Post Cross-Sectional Study in Chile

    by Dona Benadof, Mirta Acuña, Yennybeth Leiva, Daniel Conei

    Respiratory infections represent one of the leading causes of pediatric consultations and hospitalizations in Chile, where rapid etiological identification is essential for clinical decision-making. We evaluated the impact of implementing the BIOFIRE® SPOTFIRE® Respiratory (R) Panel in the pediatric Emergency Department of a public referral hospital in Santiago, using a pre–post cross-sectional design comparing two winter periods (July 2023 vs. July 2024). Clinical records, laboratory data, and operational indicators were analyzed to assess changes in diagnostic yield, turnaround time, hospitalizations, discharges, supplementary test requests, and antimicrobial use. A total of 470 patients were included (224 in 2023; 246 in 2024). The etiological detection rate increased from 58.0% to 87.8% after the implementation of Spotfire® (p < 0.0001), with marked increases in the identification of adenovirus, RSV, rhinovirus/enterovirus, and seasonal coronaviruses. Rapid molecular testing was associated with a significant rise in emergency department discharges (23.7% vs. 57.3%; p < 0.0001) and a reduction in hospitalizations (76.3% vs. 42.7%; p < 0.0001) and readmissions (9.2% vs. 0.5%; p < 0.0001). Requests for complete blood counts, chest X-rays, and antimicrobial prescriptions at discharge also decreased significantly. These effects persisted in key subgroups, including infants and children with comorbidities. In this high-demand winter setting, the BIOFIRE® SPOTFIRE® R Panel improved diagnostic performance and supported more efficient and targeted clinical management.


  • Open Access

    Evaluating the Clinical Impact of BioFire Spotfire R/ST on the Management of Pediatric Respiratory Presentations in the Emergency Department: A Pre–Post Cross-Sectional Study in Chile

    by Dona Benadof, Mirta Acuña, Yennybeth Leiva, Daniel Conei

    Respiratory infections represent one of the leading causes of pediatric consultations and hospitalizations in Chile, where rapid etiological identification is essential for clinical decision-making. We evaluated the impact of implementing the, BIOFIRE® SPOTFIRE® Respiratory (R) Panel in the pediatric Emergency Department of a public referral hospital in Santiago, using a pre-post cross-sectional design comparing two winter periods (July 2023 vs. July 2024). Clinical records, laboratory data, and operational indicators were analyzed to assess changes in diagnostic yield, turnaround time, hospitalizations, discharges, ancillary test requests, and antimicrobial use. A total of 470 patients were included (224 in 2023; 246 in 2024). The etiological detection rate increased from 58.0% to 87.8% after the implementation of Spotfire® (p < 0.0001), with marked increases in the identification of adenovirus, RSV, rhinovirus/enterovirus, and seasonal coronaviruses. Rapid molecular testing was associated with a significant rise in emergency department discharges (23.7% vs. 57.3%; p < 0.0001) and a reduction in hospitalizations (76.3% vs. 42.7%; p < 0.0001) and readmissions (9.2% vs. 0.5%; p < 0.0001). Requests for complete blood counts, chest X-rays, and antimicrobial prescriptions at discharge also decreased significantly. These effects persisted in key subgroups, including infants and children with comorbidities. In this high-demand winter setting, BIOFIRE SPOTFIRE R Panel improved diagnostic performance and supported more efficient and targeted clinical management.