XZXuejun Zhang

Xuejun Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuejun Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of Fault Protection Stra for Unified Power Flow Controller in Distribution Networks

    by Xiaochun Mou, Ruijun Zhu, Xuejun Zhang, Wu Chen, Jilong Song, Xinran Huo, Kai Wang

    The capacity of traditional distribution networks is limited. After large-scale distributed power sources are connected, it is difficult to consume them at the same voltage level, which can lead to transformer reverse overloading and voltage limit violations. Although the unified power flow controller (UPFC) excels in flexible power flow regulation and power quality optimization, existing research on it is mostly focused on the transmission grid, focusing on device topology, power flow control, etc. Fault protection is also targeted at high-voltage and ultra-high-voltage domains and only covers a single overvoltage or overcurrent fault. Research on the protection of the unified power flow controller in a distribution network (D-UPFC) remains scarce. A key challenge is the absence of fault protection schemes that are compatible with the unified power flow controller in a distribution network, which cannot meet the requirements of the distribution network for monitoring and protecting multiple fault types, rapid response, and equipment economy. This paper first designs a protection device centered on the distribution thyristor bypass switch (D-TBS), completes the thyristor selection and transient energy extraction, optimizes the overvoltage protection loop parameter, then builds a three-level coordinated protection architecture, and, finally, verifies through functional and system tests. The results show that the thyristor control unit trigger is reliable and the total overvoltage response delay is 1.08 μs. In the case of a three-phase short-circuit fault in a 600 kVA/10 kV system, the distribution thyristor bypass switch can rapidly reduce the secondary voltage of the series transformer, suppress transient overcurrent, achieve isolation protection of the main equipment, provide a reliable guarantee for the engineering application of the distribution network unified power flow controller, and expand its distribution network application scenarios.